2.11Electromagnetic immunity
When properly installed in a representative host system, the drive operates without errors or degradation in performance when subjected to the radio frequency (RF) environments defined in the following table:
Table 8: | Radio frequency environments |
|
| |
|
|
|
|
|
Test |
| Description | Performance level | Reference standard |
|
|
|
|
|
Electrostatic |
| Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV | B | EN |
discharge |
|
|
|
|
Radiated RF |
| 80 to 1,000 MHz, 3 V/m, | A | EN |
immunity |
| 80% AM with 1 kHz sine |
| ENV 50204: 95 |
|
| 900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz |
|
|
Electrical fast | ± 1 kV on AC mains, ± 0.5 kV on external I/O | B | EN | |
transient |
|
|
|
|
Surge immunity | ± 1 kV differential, ± 2 kV common, AC mains | B | EN | |
|
|
|
| |
Conducted RF | 150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 kHz sine | A | EN | |
immunity |
|
|
|
|
Voltage dips, |
| 0% open, 5 seconds | C | EN |
interrupts |
| 0% short, 5 seconds | C |
|
|
| 40%, 0.10 seconds | C |
|
|
| 70%, 0.01 seconds | B |
|
22 | Barracuda ES Serial ATA Product Manual, Rev. D |