C.SET RF SWITCH OPTIONS

1.Set Jumpers on the option card to the dotted position.

When setting the jumpers, observe that there are three pins on each header. The jumper covers two of these pins and connects them together electrically. In one position Pin 2 (center pin) is connected to Pin 1, while in the other position Pin 2 is connected to Pin 3. Changing the jumpers changes the configuration of the circuit board and how the board operates.

There is a dot on the board near either pin 1 or pin 3 of each jumper. Setting the jumper so pin 2 is connected to this pin means the jumper is in the “dotted” position. This indicates “Normal” operation of Wegener equipment.

All three of the jumpers on the RF Switch PWB should be in the “Dotted” position.

D.RE-INSTALLING THE UNIT

1.Replace the cover and re-install the screws holding it in place. As with the RF Switch, tighten the screws but do not overtighten.

2.Connect the “Output” connector of the RF Switch with the “RF Input” connector of the receiver it is installed in with the supplied F-F coax cable. Tighten the F- connector “finger tight.” See the Caution below.

3.Install the unit into the equipment rack, following the cautions and instructions in its user manual. Re-install the cables as they were when the unit was removed from the rack, with the exception in Step # D2.

4.Connect the desired RF inputs to the “F” connectors on the RF Switch. Again, observe the caution regarding the force required to tighten these connectors. Normally, the RF Inputs are configured according to instructions from the Network Control, or Uplink. They will need to know which input is connected to which connector so they can intelligently control program content.

* * * WARNING * * *

When connecting cables to “F” type connectors apply a force of no more than 12 inch lb. (Finger tight). Avoid connecting adapters directly to “F” type connectors. Use at minimum a 1-foot flexible extension cable between “F” type connectors and adapters.

E.OPERATION

To set up and operate a receiver with the RF Switch installed, consult the owner’s manual for that unit. See the “Terminal Commands” or “On Screen Display” section for setup and control.

800016-13

Page 4 of 6

Image 4
Contents Installation/Operation Guide Unity RF Switch Option Introduction Prepare the UnitInstall the RF Switch RE-INSTALLING the Unit SET RF Switch OptionsOperation Typical Two-Connector-Cable Installation Service Contact Numbers and Addresses

Unity RF Switch specifications

Wegener Communications has established itself as a leader in advanced telecommunications technology, and one of its standout products is the Unity RF Switch. This innovative device is designed to streamline and enhance the management of radio frequency signals in various applications, including broadcasting, telecommunications, and satellite communications.

The Unity RF Switch boasts several key features that set it apart in the marketplace. One of its primary functions is its ability to switch RF signals with high precision and reliability. This is crucial in environments where signal integrity is paramount, such as in live broadcasting scenarios or critical communication infrastructures. The switch is engineered to minimize signal loss, ensuring that the integrity of the transmitted data remains intact.

Another significant characteristic of the Unity RF Switch is its versatility. It is designed to accommodate a wide range of frequencies, making it adaptable to various applications. Whether handling VHF, UHF, or microwave signals, the Unity RF Switch is capable of meeting the diverse needs of today's broadcasting and telecommunications industries.

The Unity RF Switch also features advanced remote control capabilities. With the use of intuitive management software, operators can easily configure and control the switch from a distance. This remote functionality is particularly beneficial in large-scale operations or situations where equipment is located in hard-to-reach places. The software interface is user-friendly, allowing for quick adjustments and monitoring of system performance.

In terms of build quality, the Unity RF Switch is constructed with robust materials that ensure durability and reliability. It is designed to withstand various environmental conditions, making it suitable for deployment in both indoor and outdoor settings. The switch is also engineered for ease of installation, with clear documentation and support provided by Wegener Communications' expert team.

Another notable technological advancement in the Unity RF Switch is its support for automation and integration with existing broadcast systems. It can be seamlessly incorporated into complex workflows, enhancing operational efficiency. Additionally, the device supports multiplexing and demultiplexing, allowing for efficient management of multiple signals simultaneously.

In summary, the Wegener Communications Unity RF Switch is a sophisticated solution that addresses the challenges of RF signal management in modern telecommunications and broadcasting. Its high-precision switching capabilities, versatility, remote control features, and robust design make it an essential tool for professionals in the industry, ensuring seamless and reliable operation in critical applications.