Western Telematic CAS-81 manual Connect Power Cable, Connect Devices to Serial Ports

Page 8

CAS-81 Code Activated Switch, User's Guide

Installation

3.2. Connect Power Cable

Make certain that the CAS-81 power switch is set in the OFF position and then connect the power cable to the AC Power connector. Connect the other end of the power cable to a grounded AC wall outlet.

3.3. Connect Devices to Serial Ports

Serial Ports 1 - 8 are wired as standard AT 9 pin COM Ports. Connect data cables from the desired devices to Serial Ports 1 through 8. The Serial Ports accept AT 9 pin to printer or modem cables, depending on the application.

Caution:

Make certain that all data cables are compatible with the CAS-81 Serial Port interface. Please refer to Appendix A for a description of the Serial Port interface.

3.4. Connect Control Port

The Control Port is configured to appear as a 25 pin DCE modem and accepts a standard PC to Modem straight wired cable. Use a "Null Modem Cable" to connect a modem to the Control Port. For a description of the Control Port Interface, please refer to Appendix A.

3.5. RS422 Line Driver Option

Each Serial Port may be configured with an optional RS422 balanced line driver. These long distance line drivers can extend high speed transmission distance to 4,000 feet using 2 twisted pair wiring. Only the TXD and RXD signals are transmitted. The DCD and CTS signals are set to high.

To install the optional RS422 module, simply remove the RS232 Driver chip located on the circuit board adjacent to the desired Serial Port’s connector and plug in the RS422 module. An LED viewed from the back panel will indicate that the port is RS422. Please refer to Appendix A for a description of the RS422 Serial Port interface.

3-3

Image 8
Contents CAS-81 Users GuideTable of Contents Typographic Conventions IntroductionApplications Front Panel Indicators Unit DescriptionBack Panel Back PanelInstallation Set DIP SwitchesData Rate Baud Selection Switches 1 through Timeout Selection Switches 4Auto Connect Serial Port 1 Switch Broadcast Mode SwitchForce CTS Switch Force DCD SwitchConnect Power Cable Connect Devices to Serial PortsConnect Control Port RS422 Line Driver OptionPower Up Command StringOperation Ascii CharactersCommand Response Port GatingOpen Port Gating Close Port GatingDescription of System Interfaces Control Port DB25 FemaleSerial Ports 1 through 8 DB9 Male 1. RS422 Line Driver OptionSpecifications Command ResponseFCC Notice InterfaceCustomer Service Trademark and Copyright Information