4.Operation

4.1. Power Up

The ON LED indicates that AC Power has been turned on. The RDY LED indicates that the processor is operating and the unit is READY to operate. A flickering RDY LED indicates an AC Power brown out condition. The Control Port Status LEDs indicate the signal status of the Control Port. The Serial Port LEDs indicate the port(s) selected. When all Serial Port LEDs are lit, this indicates that CAS-81's Broadcast Mode is active.

Upon power-up, the unit is programmed according to the parameters selected by the setup DIP switches, which are located next to the Control Port. (Refer to switch setup section). If you change any of the DIP Switch settings while the unit is powered on, you must turn power off and on to reread the switch.

4.2. ASCII Characters

The PC or controlling device connected to the Control Port must send ASCII characters at the same data rate as the CAS-81. The unit accepts 8 bits / no parity, or 7 bits / even parity.

4.3. Command String

The command string consists of seven contiguous characters. The first 6 characters are ASCII Control codes, and the seventh is the configuration code.

^V^X^X^V^X^Xn (Command String)

Where:

n = 0

Disconnects

n = 1 - 8

Selects Serial Port Number 1 through 8

n = 9

Enables Broadcast Mode (Select All Serial Ports)

Note that if "n" equals any character other than 0 through 9, the command will be terminated.

Examples:

To select port 3, send the following command:

^V^X^X^V^X^X3

To disconnect, send the following command:

^V^X^X^V^X^X0

4-1

Image 9
Contents Users Guide CAS-81Table of Contents Introduction ApplicationsTypographic Conventions Unit Description Front Panel IndicatorsBack Panel Back PanelSet DIP Switches InstallationData Rate Baud Selection Switches 1 through Timeout Selection Switches 4Broadcast Mode Switch Auto Connect Serial Port 1 SwitchForce CTS Switch Force DCD SwitchConnect Devices to Serial Ports Connect Power CableConnect Control Port RS422 Line Driver OptionCommand String Power UpOperation Ascii CharactersPort Gating Command ResponseOpen Port Gating Close Port GatingControl Port DB25 Female Description of System Interfaces1. RS422 Line Driver Option Serial Ports 1 through 8 DB9 MaleCommand Response SpecificationsFCC Notice InterfaceTrademark and Copyright Information Customer Service