Teledyne PEM 9002 manual Memory Functions, Memory Calls up the memory program, Case

Page 30

6.6.4 Menu Line 4

From the Measuring Program:

6.6.4.1 Memory Functions

Hold

 

Interm. storage of measured values

S1

 

 

 

Memory Calls up the memory program

S2

 

 

 

Hold Memory Print

Case 1:

No Files

are existend

New File Edit.Text Return

Case 2:

Example:

Memory 3

No. 123-456-789

Bill Oldman

96969 New York

New File

Edit.text

Return

25

Image 30
Contents PEM Page Page Warranty Summary Page Table of Contents Product Description SO2Measuring Procedure Instrument Description Physical Data 20.9 CO2 = CO2max * 1 ------- in % VolumeCalculation Formulae QA = T.Gas T.Air * ---------- + B in %Technical Data Combustion Air or Ambient Temperature MeasurementDraft or Pressure Measurement Oxygen O2 Measurement Carbon dioxide CO2 CalculationCarbon monoxide CO Measurement with H2 compensation Options Nitrogen monoxide no Measurement CO Measurement without H2 compensationSulphur dioxide SO2 Measurement Front Panel Overview Keypad Functions Gas Feed Pump On / OffUser Guide Program Start MenuCalibration Menu BattFuel Selection Natural GasAdditional Functions of the Measuring Program Gas Feed PumpDraft Measurement Menu Lines 20.9 Menu LineMenu Information Box Menu Time and Date Menu Graphic Menu Core of waste gas flow Max. Draft Menu CO Purge System manualMenu Units Menu O2 ReferenceMenu Additional Data add. Data Advance to the next digit positionTerminate editing function Memory Functions Memory Calls up the memory programCase Case 1 No memory blocks created Create new memory blockMemory Case 2 Memory blocks already existGraphics display of measured values Other Memory FunctionsViews selected memory blocks Prints the stored measurementMenu Create Memory Blocks ABC abc Selects the next entry line Returns to the measuring menuMenu Delete Memory Data Terminates memory function Intermediate storage of measured values Printing the Measured ValuesPrintout of current measuring values Printout of measured valuesSwitches the acoustic signal On / Off Stores the configuration dataAborts the Configuration Menu Reset Resets all instrument parameters Confirm ResetEntering the Company Address CompanyPumps and sensors System MaintenanceSee drawing on Moderately. Ensure sufficient sealing by means of O-ringsBattery / Line Voltage Operation Status displayInformation on Charging the Battery Page Loading Paper Waste Gas Cleaning System PEM 9002 Filters and other cleaner parts

PEM 9002 specifications

The Teledyne PEM 9002 is a sophisticated power electronics module designed for a variety of demanding applications in the aerospace and defense sectors. Known for its high reliability and advanced features, the PEM 9002 is specifically engineered to handle the challenges posed by harsh environments while ensuring optimal performance and efficiency.

One of the main features of the Teledyne PEM 9002 is its ability to provide power conversion in a compact and lightweight form factor. This module is designed with a focus on space optimization, making it ideal for use in applications where size and weight are critical factors, such as in satellite systems and unmanned vehicles. The PEM 9002 supports a wide range of input voltages, enabling it to accommodate various power sources while ensuring seamless integration into existing systems.

Another significant characteristic of the PEM 9002 is its advanced thermal management system. Utilizing cutting-edge cooling technologies, the module maintains operational integrity in high-temperature environments, which is essential for prolonged mission profiles. This thermal efficiency not only extends the lifespan of the module but also enhances its overall reliability, making it a preferred choice for mission-critical applications.

The PEM 9002 is equipped with an array of protective features designed to safeguard against electrical anomalies, such as over-voltage, under-voltage, and over-current conditions. These built-in protections ensure the safety and stability of connected systems, reducing the risk of component damage and system failure. Furthermore, its redundant design facilitates continuous operation, even in the event of a single component failure.

In addition to its robust physical design, the Teledyne PEM 9002 incorporates advanced digital communication capabilities, allowing for real-time monitoring and diagnostics. This feature enables operators to track performance metrics and troubleshoot issues, enhancing operational efficiency and reducing downtime. The integration of digital technologies also supports compatibility with modern control systems, broadening the scope of applications for which the PEM 9002 is suitable.

Overall, the Teledyne PEM 9002 stands out in the field of power electronics for its combination of advanced features, robust design, and high reliability. Whether deployed in aerospace missions or defense applications, this module continues to demonstrate its ability to meet the rigorous demands of today’s technology landscape, ensuring success in critical operations. With its proven performance and innovative approach, the PEM 9002 is an invaluable asset to any system requiring reliable power management.