Teledyne PEM 9002 manual Menu Additional Data add. Data, Advance to the next digit position

Page 29

6.6.3.3 Menu: Additional Data (add. Data)

From the measuring program:

Add.Data Calls up menu for entering additional data

S2

 

 

Select Line

 

Select

 

S2

 

 

 

 

 

Edit

 

Change Value

 

S1

Change numerical value

Advance to the next digit position

ENTER

Return

Terminate editing function

S3

 

 

 

Unit

O2-ref.

Add.Data

smoke-no.

. - . - .

Oilderivate

. . . .

T.boiler:

 

0 °F

 

 

 

 

Edit

 

Select

Return

The selected option is shown in a frame.

A flashing cursor appears at the first entry position.

Select between Yes and No for oil derivatives.

24

Image 29
Contents PEM Page Page Warranty Summary Page Table of Contents SO2 Product DescriptionMeasuring Procedure Instrument Description Physical Data Calculation Formulae CO2 = CO2max * 1 ------- in % Volume20.9 QA = T.Gas T.Air * ---------- + B in %Draft or Pressure Measurement Technical DataCombustion Air or Ambient Temperature Measurement Carbon monoxide CO Measurement with H2 compensation Oxygen O2 MeasurementCarbon dioxide CO2 Calculation Sulphur dioxide SO2 Measurement Options Nitrogen monoxide no MeasurementCO Measurement without H2 compensation Front Panel Overview Gas Feed Pump On / Off Keypad FunctionsProgram Start Menu User GuideBatt Calibration MenuNatural Gas Fuel SelectionGas Feed Pump Additional Functions of the Measuring ProgramDraft Measurement Menu Lines Menu Line 20.9Menu Information Box Menu Time and Date Menu Graphic Menu CO Purge System manual Menu Core of waste gas flow Max. DraftMenu O2 Reference Menu UnitsTerminate editing function Menu Additional Data add. DataAdvance to the next digit position Case Memory FunctionsMemory Calls up the memory program Create new memory block Case 1 No memory blocks createdCase 2 Memory blocks already exist MemoryViews selected memory blocks Other Memory FunctionsGraphics display of measured values Prints the stored measurementMenu Create Memory Blocks ABC abc Returns to the measuring menu Selects the next entry lineMenu Delete Memory Data Terminates memory function Printout of current measuring values Printing the Measured ValuesIntermediate storage of measured values Printout of measured valuesAborts the Configuration Menu Switches the acoustic signal On / OffStores the configuration data Resets all instrument parameters Confirm Reset ResetCompany Entering the Company AddressSee drawing on System MaintenancePumps and sensors Moderately. Ensure sufficient sealing by means of O-ringsStatus display Battery / Line Voltage OperationInformation on Charging the Battery Page Loading Paper Waste Gas Cleaning System PEM 9002 Filters and other cleaner parts

PEM 9002 specifications

The Teledyne PEM 9002 is a sophisticated power electronics module designed for a variety of demanding applications in the aerospace and defense sectors. Known for its high reliability and advanced features, the PEM 9002 is specifically engineered to handle the challenges posed by harsh environments while ensuring optimal performance and efficiency.

One of the main features of the Teledyne PEM 9002 is its ability to provide power conversion in a compact and lightweight form factor. This module is designed with a focus on space optimization, making it ideal for use in applications where size and weight are critical factors, such as in satellite systems and unmanned vehicles. The PEM 9002 supports a wide range of input voltages, enabling it to accommodate various power sources while ensuring seamless integration into existing systems.

Another significant characteristic of the PEM 9002 is its advanced thermal management system. Utilizing cutting-edge cooling technologies, the module maintains operational integrity in high-temperature environments, which is essential for prolonged mission profiles. This thermal efficiency not only extends the lifespan of the module but also enhances its overall reliability, making it a preferred choice for mission-critical applications.

The PEM 9002 is equipped with an array of protective features designed to safeguard against electrical anomalies, such as over-voltage, under-voltage, and over-current conditions. These built-in protections ensure the safety and stability of connected systems, reducing the risk of component damage and system failure. Furthermore, its redundant design facilitates continuous operation, even in the event of a single component failure.

In addition to its robust physical design, the Teledyne PEM 9002 incorporates advanced digital communication capabilities, allowing for real-time monitoring and diagnostics. This feature enables operators to track performance metrics and troubleshoot issues, enhancing operational efficiency and reducing downtime. The integration of digital technologies also supports compatibility with modern control systems, broadening the scope of applications for which the PEM 9002 is suitable.

Overall, the Teledyne PEM 9002 stands out in the field of power electronics for its combination of advanced features, robust design, and high reliability. Whether deployed in aerospace missions or defense applications, this module continues to demonstrate its ability to meet the rigorous demands of today’s technology landscape, ensuring success in critical operations. With its proven performance and innovative approach, the PEM 9002 is an invaluable asset to any system requiring reliable power management.