Vector BD051605, VEC1028POB user manual Table of Contents

Page 3

This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

TABLE OF CONTENTS

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 AC and DC Charging/Recharging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Viewing Battery Charge Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 120 Volt AC Charging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 12 Volt DC Charging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Using the Power Center as a Jump-Starter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Using the 12 Volt Portable Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Using the 120 Volt AC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Using the Emergency Area Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Using the Air Compressor/Inflator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Inflating Products With a Valve Stem Using the Compressor . . . . . . . . . . . . . . . 7 Inflating Products Without a Valve Stem Using the Compressor . . . . . . . . . . . . . 8 Using the Inflator/Deflator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Battery Replacement/Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Fuse Replacement (DC Accessory Adapter) . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

INTRODUCTION

Thank you for purchasing the VEC1028POB Power Center. Please read this guide carefully before use to ensure optimum performance and avoid damage to the unit.

FEATURES

Powers 110/120 volt AC appliances

Powers 12 volt DC appliances

Jump-starts vehicle engines

Built-in air compressor/inflator with pressure gauge, hoses and adapters

Built-in 400 watt inverter

Includes non-spillable, maintenance-free, heavy-duty, sealed battery

Safe to use, transport and store

Reverse polarity connection warning

Self-stored jumper cables

Requires no maintenance (other than recharging) for optimum operation

Rechargeable with built-in AC charger

Unique compact design provides completely portable 12 volt DC power

Molded high-impact case is tough and durable

Built-in area light for night time roadside repairs and use in remote locations without utility power

Battery charge level indicators

iv

1

Image 3
Contents Power Center Important Safety Instructions Table of Contents Protective Features Viewing Battery Charge StatusAC and DC CHARGING/RECHARGING Jump-Starting Instructions Using the Power Center AS a JUMP-STARTERVolt AC Charging Volt DC ChargingAC Power Supply Operation Using the AIR COMPRESSOR/INFLATORUsing the 120 Volt AC Power Supply AC Power Supply Controls and IndicatorsFuse Replacement DC Accessory Adapter Care and MaintenanceUsing the Inflator/Deflator Replacement PartsTire Inflator Specifications SpecificationsVolt DC Specifications AC Power Specifications

BD051605, VEC1028POB specifications

Vector BD051605 and VEC1028POB are two innovative products in the realm of advanced vehicle technology, specifically designed for enhancing mobility and engineering applications. These devices embody exceptional design and functionality, catering to various modern vehicular needs.

The Vector BD051605 is a high-performance controller that is primarily aimed at managing electric motor operations in electric and hybrid electric vehicles. Its standout features include a versatile communication interface, enabling integration with multiple sensors and control units. This flexibility allows it to be employed in a variety of vehicle platforms. The BD051605 supports advanced modulation techniques which contribute to improved efficiency and performance of electric drive systems. With its robust thermal management design, this controller ensures reliable operation even under demanding conditions, making it a preferred choice for manufacturers seeking optimum reliability.

On the other hand, the VEC1028POB is a compact yet powerful power distribution unit known for its capability to manage multiple electrical loads seamlessly. This unit incorporates state-of-the-art technologies that enhance safety and efficiency across various electrical systems. A notable feature is its integrated fault detection mechanism, which provides real-time diagnostics and predictive maintenance alerts. This characteristic not only enhances reliability but also minimizes downtime, which is critical in commercial applications.

Both devices leverage cutting-edge technologies such as CAN bus communications, which facilitate high-speed data transfer between components, ensuring that information is readily available for decision-making processes. The integration of advanced algorithms within both the BD051605 and VEC1028POB allows for dynamic adjustments according to vehicle performance parameters, optimizing energy usage and improving overall vehicle efficiency.

In conclusion, Vector BD051605 and VEC1028POB combinedly represent a significant leap forward in vehicle technology. Their superior features, including enhanced communication, reliability, and real-time diagnostics, position them as essential components for contemporary electric and hybrid vehicles. As the automotive industry continues to evolve towards greater electrification and automation, these technologies provide practical solutions that support this transition while ensuring safety and performance efficiency. Their implementation not only drives advancements in vehicle engineering but also aligns with the growing demand for sustainable mobility solutions.