■With Operation Key Inserted
Horizontal Mounting D4BL +
Vertical Mounting D4BL +
Red
53.5 min. 57 max.
(12)
(41)
Red
54.5 min. 58 max.
(13)
(41)
Horizontal direction | Vertical direction |
Operation Key insertion radius | Operation Key insertion radius |
R ≥ 1200 | R ≥ 1000 |
53.5 min. 57 max.
(20±0.15)
(20±0.15)
(41)
(35)
Vertical direction
Operation Key insertion radius
Horizontal directionR ≥ 1000 Operation Key insertion radius
R ≥ 1200
54.5min. 58 max.
(41)
(40±0.15)
(35)
Safety Door Switches D4BL
Adjustable Mounting (Horizontal)
D4BL + | Red |
81.5 min. 85 max.
(41) (40)
Horizontal direction
Operation Key insertion radius
R ≥ 250
81.5 min. 85 max.
(41)
(30±0.15)
Vertical direction
Operation Key insertion radius R ≥ 1000
(35)
Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2.In the above diagrams, the Operation Key is inserted from the front.
Guard Lock |