Omron D4BL manual Solenoid Lock Models, Switch and Operation Key Mounting, Mounting Dimensions

Page 13

Solenoid Lock Models

The solenoid lock locks the door only when power is supplied to the solenoid. Therefore, the door will be unlocked if the power supply to the solenoid stops. Therefore, do not use solenoid lock models for machines that may be operating and dangerous even after the machine stops operating.

Switch and Operation Key Mounting

Mount the D4BL and Operation Key with four M5 screws with washers and tighten each screw to the specified torque.

Mounting Dimensions

Switch Mounting Dimensions

Four, M5

74±0.1

100±0.1

Operation Key Mounting Holes

Operation Key

The D4BL is provided with a shock-absorbing damper to protect the D4BL from damage that may result from dropping the D4BL during transportation. Be sure to remove the damper after mounting the D4BL.

The mounting tolerance of the Operation Key is ±0.3 mm vertically or horizontally. Be sure to mount the D4BL correctly without leaning, otherwise the D4BL may soon break or wear out.

Observe the specified insertion radius for the Operation Key and

SafetyDoor Switches

 

than ±0.3

insert it in a direction perpendicular to the key hole.

 

Incorrect

Greater

 

D4BL

Incorrect

Greater than ±0.3

The Operation Key for the D4BL is different from the one for the D4BS.

Horizontal Mounting D4BL-K1

20±0.1

Vertical Mounting D4BL-K2

40±0.1

Adjustable Mounting (Horizontal) D4BL-K3

Two, M5

Two, M5

Head Direction

The head can be mounted in four directions. To remove the head, turn the head by 45° as shown in figures (A) and (B) below.

To change the direction of the head, make sure that the protruding part of the rotating lever engages with the groove of the plunger. Then turn the head clockwise or counterclockwise to the desired direction. At that time, make sure that the groove of the plunger is located under the rotating lever. If the direction of the head is not set when the plunger is rotated by 45°, the groove of the plunger presses the rotating lever. The head, plunger, or the built-in switch may be damaged as a result.

Head Direction Changes

Two, M5

30±0.1

Left

Front

(45°)

(45°)

(A)(B)

Back

Right

Head Bottom View

Switch Top View

Operation plunger and

Rotation lever and

groove mechanism

protruding part

Guard Lock Safety-door Switch D4BL

A-79

Image 13
Contents Model Number Legend Model Number StructureOrdering Information SpecificationsList of Models Standards and EC DirectivesApproved Standard Ratings CharacteristicsTÜV EN60947-5-1, CCC GB14048.5 UL/CSA UL508, CSA C22.2 NoConnections Indicator UnitContact Form 2NC + 2NC Circuit Connection Example D4BL Connection Example with OMRON’s G9SA Safety Relay UnitKM1 D4BL-@C@@-@ D4BL-@D@@-@ NomenclatureSwitches DimensionsOperating Characteristics D4BL-@@@@ D4BL-@@@@-@Operation Keys Adjustable Mounting HorizontalHorizontal Mounting Vertical Mounting D4BL-K1 D4BL-K2 With Operation Key Inserted Adjustable Mounting Horizontal D4BL + D4BL-K3Precautions for Safe Use Safety PrecautionsPrecautions for Correct Use Mounting Dimensions Switch and Operation Key MountingSolenoid Lock Models Operation KeyMounting the Cover Processing and Connecting Cable/ConduitCable Connection Example OthersTerms and Conditions of Sale Certain Precautions on Specifications and Use$$*+ $%&&&$