Omnitron Systems Technology AS400/3X, AS5250 Operation, Sample Applications, Ordering Information

Page 2

while providing superior noise and crosstalk immunity.

The Express models operate with both the 5250 and 5250 Express protocols. Each port provides data rates of 1 Mbps for standard 5250 and 2 Mbps for 5250 Express protocol.

The OmniRepeater 400 is completely software-transparent and no setup or any changes are required.

OPERATION

Inputs: The OmniRepeater 400 is built around a Digital Phased Locked Architecture (PLA). This technology allows effective discrimination between true data and noise. The incoming Manchester encoded data is sampled at 16 samples per bit, which facilitates digital filtering of noise and crosstalk. A unique clock recovery facilitates the capture of data with rate variations of -2% to +4%.

Processing: Once the data is recovered and synchronized, it is processed. The processor analyzes the frame header. If a legal header is detected, the port is “marked” active and the data is allowed to flow through the repeater.

Outputs: The retransmitted data is regenerated, reclocked and lost sync bits are recovered. The data is reclocked at 50% duty cycle to eliminate clock jitter. The signal is restored to nominal amplitude and the pre-distortion logic compensates for anticipated phase shift and attenuation.

Displays: True data activity and parity errors are displayed by green and red LEDs. The green activity LEDs assist in monitoring signal strength while the red Parity Error LEDs assist in monitoring connectivity quality, signal strength, impedance mismatches and reflections.

SAMPLE APPLICATIONS

The following picture depicts three typical applications of the OmniRepeater 400:

In the first case, the host (a) twinax signal is repeated and reclocked by the OmniRepeater (b) and workstation distance from the host is extended to 10,000 feet (c).

In the second case, the OmniRepeater (d) converts the twinax data to fiber and then back to twinax via a second OmniRepeater (e).

In the third case, twinax is converted to fiber (g) via the OmniRepeater and then to twisted pair via an OmniMux(h) which delivers it to the workstations (k).

SPECIFICATIONS

nProtocol:IBM 5250 and 5250 Express for Systems AS/400, 3X

nInterface:

Link:

One (1) Twinax, One (1) Fiber or

 

One (1) RJ11/45, One (1) Fiber

Port:

One (1) Twinax or

 

One (1) RJ11/45

 

(RJ11 pins 3-4, RJ45 pins 4-5 are standard)

nCable Types:

Twinax:IBM 7362229 or equivalent

UTP:Category 3 (EIA/TIA 568) or higher, (shorter distance @ lower grade)

nData Rate:

Standard 5250:

1 Mbps -2%, +4%

5250 Express:

1 or 2 Mbps -2%, +4%

nSupported Distances:

Twinax:

5,000

ft.

UTP:

3,000

ft.

Multimode Fiber:

15,000

ft.

Singlemode Fiber:

30,000

ft.

nPhysical features:

Rackmounted:

W:19.0"xD:6.0"xH:1.75"

Tabletop:

W:17.5"xD:6.0"xH:1.75"

Weight:

7 lbs.

n Power:

115 or 230 VAC, 150 mA

nTemperature:

Operating:

0 to 40 degrees C

Storage:

-40 to 75 degrees C

nHumidity:Up to 90% (non condensing)

ORDERING INFORMATION

Standard 5250

5250 Express Description

2651

2661

Twinax to Twinax and Fiber

2653

2663

Twinax to Twinax Only

Trademarks are owned by their respective companies OmniMux, OmniStar, OmniRepeater are trademarks of Omnitron Systems Technology, Inc.

Specifications subject to change without notice. ©1993-2001Omnitron Systems Technology, Inc.

091-02651-002 11/01

Omnitron Systems

Technology, Inc.

27 Mauchly #201, Irvine, CA 92618

Tel: (949) 250-6510 Fax: (949) 250-6514

E-mail: info@omnitron-systems.com

http://www.omnitron-systems.com