Management Options iConverter, Serial Agent
Network Management
1:Chassis and Module Management
2:Set Module Name Preferences Management Module Preferences
3:IP and Control Preferences
4:SNMP Preferences
5:Abandon Preference Changes
6:Save Preference Changes
7:Restore Factory Defaults
8:Restart Management Module
9:Other Networking Features Management Module Maintenance
10:Firmware Update
11:Set Date/Time
IP Address = 192.168.1.220
Chassis Number = 1
Enter Choice, <H>elp, E<x>it >
Figure D: Command Line Interface Menu Options
The CLI interface allows for the detailed configuration of the module. It is recommended to configure the module with an IP address associated with the attached network. Also, SNMP traphost address should be configured if the module is managed with an
iConverter 2FXM Plug-in Module QUICK START GUIDE
The Omnitron iConverter® 2FXM Network Interface Device (NID) with integrated management provides Fast Ethernet
The 2FXM conforms to Ethernet in the First Mile (EFM) fiber standards to support
The 2FXM module can be managed using Omnitron’s NetOutlookTM SNMP Management Software, 3rd Party SNMP Client, Telnet or the Command Line Interface (CLI).
For more information, including the complete User Manual on the 2FXM
INSTALLATION PROCEDURE
1)Configure
2)Install Module in Chassis and Connect Cables
3)Configure Module via Command Line Interface
4)Verify Operation
1) CONFIGURE |
4) VERIFY OPERATION
Once the module has been installed and configured per steps 1 - 3, verify the module is operational by viewing the LED indicators.
The Power LED indicates the module is receiving power from the chassis.
The Fiber Optic link LEDs indicate the fiber optic connections have been established. Verify the Link Mode selection is set to Link Segment (LS). Until a stable
LED Function | Color | Off State | On / Blinking State | |
"Legend" | ||||
|
|
| ||
|
|
|
| |
Power "Pwr" | Amber | No power | On: Module has power | |
|
|
| On: Power available from | |
Power Supply Status | Amber | Chassis Power | installed Power Supply #X | |
#X | Supply not installed | Blinking: No power available | ||
|
|
| from installed Power Supply #X | |
Port 1 |
|
| On: Fiber link is active | |
Fiber Link Activity | Green | No Fiber Link | ||
Blinking: Fiber Data Activity | ||||
"P1" |
|
| ||
|
|
| ||
Port 1 |
|
|
| |
Half/Full Duplex | Green | On: | ||
"FDX" |
|
|
| |
Chassis Management |
| Chassis Slave | On: Chassis Master | |
Master/Slave | Green | Blinking: Operating in OAM | ||
Mode | ||||
"Msr/Slv" |
|
| Mode | |
Port 2 |
|
| On: Fiber link is active | |
Fiber Link Activity | Green | No Fiber Link | ||
Blinking: Fiber Data Activity | ||||
"P2" |
|
| ||
|
|
| ||
Port 2 |
|
|
| |
Half/Full Duplex | Green | On: | ||
"FDX" |
|
|
|
|
SW1 - PAUSE ENABLE
When the Pause Enable
Switch 1
Bank 2
Switch 8
Switch 1
Bank 1
Switch 8
LEFT | RIGHT |
Figure A: DIP-Switch Locations
link is established, leave the | Figure E: LED Indicators | |
Link Mode configured for LS. | ||
|
After a Link presence is established, the Link Mode selection can be modified.
Form
SW2 - FIBER PORT 1 FULL/HALF DUPLEX
Setting this
Omnitron Systems Technology * 140 Technology Dr. #500 * Irvine, CA 92618
949.250.6510 tel * 949.250.6514 fax *