SW3 AND SW4 - RESERVED
These
SW5 - FIBER PORT 2 FULL/HALF DUPLEX
Setting this
SW6, SW7, SW8 - LINK MODES
The module supports multiple link modes for fault detection and isolation. Link Segment should be used for the initial installation of the module. Once installed and operational, the link mode can be modified.
installed management modules to the RIGHT “SL” position to enable
SW5, SW6, SW7, SW8 - RESERVED
These
2) INSTALL MODULE IN CHASSIS AND CONNECT CABLES
a. Carefully slide the module into an open slot in the chassis. Align the module with |
the installation guides and ensure that the module is firmly seated against the |
backplane. Secure the module by fastening the front panel thumbscrew (push in |
and turn clockwise to tighten) to the chassis front. Verify the “Pwr” LED is ON |
(indicating the chassis is powered). |
Switch | Left | Right |
| (Factory Default) |
|
SW1 | Off: | PAUS: |
| Pause Disable | Pause Enable |
SW2 | FDX: | HDX: |
| Fiber Port | Fiber Port |
SW3 | Reserved | Reserved |
|
|
|
SW4 | Reserved | Reserved |
|
|
|
SW5 | FDX: | HDX: |
| Fiber Port 2 | Fiber Port |
SW6 |
|
|
|
|
|
SW7 | See Link Mode Selection | |
| ||
|
|
|
SW8 |
|
|
|
|
|
SW6 | SW7 | SW8 | Link Mode Selection |
|
|
|
|
Left | Left | Left | Link Segment (LS) |
|
|
| (Factory Default) |
Right | Left | Left | Link Propagate (LP) |
|
|
|
|
Left | Right | Left | Remote Fault Detect + Link |
|
|
| Segment (RFD + LS) |
Right | Right | Left | Remote Fault Detect + Link |
|
|
| Propagate (RFD + LP) |
|
|
|
|
Left | Left | Right | Symmetrical Fault Detect (SFD) |
|
|
|
|
Right | Left | Right | Illegal Setting |
|
|
|
|
Left | Right | Right | Illegal Setting |
|
|
|
|
Right | Right | Right | Illegal Setting |
|
|
|
|
b. Insert the SFP Fiber transceivers into the Port 1 and Port 2 SFP receptacles on the |
2FXM. |
NOTE: The release latch of the SFP Fiber transceiver must be in the closed position before insertion.
d.Connect an appropriate multimode or
NOTE: In order to support Remote OAM Management Mode, Port 1 of the 2FXM must be connected to the Port 1 on the 2FXM or link partner.
3) CONFIGURE MODULE VIA COMMAND LINE INTERFACE
Figure B: DIP-Switch Bank 1
DIP-SWITCH BANK 2
SW1, SW2 - BACKPLANE ENABLE
When the
To access the Command Line Interface (CLI), connect the 2FXM
Start HyperTerminal and select the correct COM Port in the HyperTerminal “Connect To:” window. Set the serial port to the following:
Bits Per Second | 57,600 |
Stop Bits | 1 |
Data Bits | 8 |
SW4 - MASTER/SLAVE
When the 2FXM module is installed in a chassis with an iConverter Network Management Module (NMM), set
Switch | Left | Right |
| (Factory Default) |
|
SW1 | ||
| Backplane Port A | Backplane Port A |
SW2 | ||
| Backplane Port B | Backplane Port B |
SW3 | Reserved | Reserved |
|
|
|
SW4 | M/SL: | SL: |
| Auto Select | |
SW5 - SW8 | Reserved | Reserved |
Figure C: DIP-Switch Bank 2
Parity | NONE |
Hardware Flow Control | NONE |
Once connected, press <ENTER> to bring up a command line prompt on the attached PC. A new 2FXM module does not have a password, and will skip the Password Entry screen and go straight to the Management Options screen. If a password has been set, the Password Entry screen will be displayed. Type the password and press <ENTER>, the 2FXM will respond with the Management Options screen: