Omnitron Systems Technology iConverter 2FXM Install Module in Chassis and Connect Cables

Page 2

SW3 AND SW4 - RESERVED

These DIP-switches are for factory use only and must always remain in the LEFT (factory default) position.

SW5 - FIBER PORT 2 FULL/HALF DUPLEX

Setting this DIP-switch to Half-Duplex “HDX” facilitates a connection that supports Half-Duplex. Setting this DIP-switch to Full-Duplex “FDX” facilitates a connection that supports Full-Duplex operation.

SW6, SW7, SW8 - LINK MODES

The module supports multiple link modes for fault detection and isolation. Link Segment should be used for the initial installation of the module. Once installed and operational, the link mode can be modified.

installed management modules to the RIGHT “SL” position to enable Slave-Only mode.

SW5, SW6, SW7, SW8 - RESERVED

These DIP-switches are for factory use only and must always remain in the LEFT position (factory default).

2) INSTALL MODULE IN CHASSIS AND CONNECT CABLES

a. Carefully slide the module into an open slot in the chassis. Align the module with

the installation guides and ensure that the module is firmly seated against the

backplane. Secure the module by fastening the front panel thumbscrew (push in

and turn clockwise to tighten) to the chassis front. Verify the “Pwr” LED is ON

(indicating the chassis is powered).

Switch

Left

Right

 

(Factory Default)

 

SW1

Off:

PAUS:

 

Pause Disable

Pause Enable

SW2

FDX:

HDX:

 

Fiber Port 1Full-Duplex

Fiber Port 1Half-Duplex

SW3

Reserved

Reserved

 

 

 

SW4

Reserved

Reserved

 

 

 

SW5

FDX:

HDX:

 

Fiber Port 2 Full-Duplex

Fiber Port 2Half-Duplex

SW6

 

 

 

 

 

SW7

See Link Mode Selection

 

 

 

 

SW8

 

 

 

 

 

SW6

SW7

SW8

Link Mode Selection

 

 

 

 

Left

Left

Left

Link Segment (LS)

 

 

 

(Factory Default)

Right

Left

Left

Link Propagate (LP)

 

 

 

 

Left

Right

Left

Remote Fault Detect + Link

 

 

 

Segment (RFD + LS)

Right

Right

Left

Remote Fault Detect + Link

 

 

 

Propagate (RFD + LP)

 

 

 

 

Left

Left

Right

Symmetrical Fault Detect (SFD)

 

 

 

 

Right

Left

Right

Illegal Setting

 

 

 

 

Left

Right

Right

Illegal Setting

 

 

 

 

Right

Right

Right

Illegal Setting

 

 

 

 

b. Insert the SFP Fiber transceivers into the Port 1 and Port 2 SFP receptacles on the

2FXM.

NOTE: The release latch of the SFP Fiber transceiver must be in the closed position before insertion.

d.Connect an appropriate multimode or single-mode fiber cable to the SFP fiber ports of the installed module. It is important to ensure that the transmit (TX) is attached to the receive side of the device at the other end and the receive (RX) is attached to the transmit side. Single-fiber (SF) media converter models operate in pairs. The TX wavelength must match the RX wavelength at the other end and the RX wavelength must match the TX wavelength at the other end.

NOTE: In order to support Remote OAM Management Mode, Port 1 of the 2FXM must be connected to the Port 1 on the 2FXM or link partner.

3) CONFIGURE MODULE VIA COMMAND LINE INTERFACE

Figure B: DIP-Switch Bank 1

DIP-SWITCH BANK 2

SW1, SW2 - BACKPLANE ENABLE

When the DIP-switch is in the LEFT “DS” position (factory default), the Backplane Port of the 2FXM is isolated from the chassis’ Ethernet Backplane. When the DIP-switch is in the RIGHT “EN” position, the Backplane Port is enabled. Thisallows Ethernet Backplane connectivity to an adjacent module via the chassis Backplane Link “A” or “B” depending on the switch setting.

To access the Command Line Interface (CLI), connect the 2FXM RS-232 Console Port to the COM port of a computer equipped with terminal emulation software such as HyperTerminal. The Console Port (DCE) is a mini DIN-6 female connector which can be changed to a DB-9 connector with the included adapter. The 2FXM Console Port is a standard asynchronous serial interface.

Start HyperTerminal and select the correct COM Port in the HyperTerminal “Connect To:” window. Set the serial port to the following:

Bits Per Second

57,600

Stop Bits

1

Data Bits

8

SW4 - MASTER/SLAVE

When the 2FXM module is installed in a chassis with an iConverter Network Management Module (NMM), set DIP-switch to the LEFT “M/SL” position (factory default). The assignment of mastership is automatically negotiated by the installed management modules. To designate the 2FXM module as the master of the chassis, set the DIP- switch to the LEFT “M/SL” position, and set the DIP-switch of the other

Switch

Left

Right

 

(Factory Default)

 

SW1

A-DS: Disabled

A-EN: Enabled

 

Backplane Port A

Backplane Port A

SW2

B-DS: Disabled

B-EN: Enabled

 

Backplane Port B

Backplane Port B

SW3

Reserved

Reserved

 

 

 

SW4

M/SL:

SL:

 

Auto Select

Slave-Mode Only

SW5 - SW8

Reserved

Reserved

Figure C: DIP-Switch Bank 2

Parity

NONE

Hardware Flow Control

NONE

Once connected, press <ENTER> to bring up a command line prompt on the attached PC. A new 2FXM module does not have a password, and will skip the Password Entry screen and go straight to the Management Options screen. If a password has been set, the Password Entry screen will be displayed. Type the password and press <ENTER>, the 2FXM will respond with the Management Options screen:

Image 2
Contents DIP-SWITCH Bank Installation ProcedureConfigure DIP-SWITCHES Verify OperationInstall Module in Chassis and Connect Cables Configure Module VIA Command Line Interface