Appendix D - Ground Loop Phenomenon

Appendix D - Ground Loop Phenomenon

What is Ground Loop?

Ground loop Phenomenon occurs when two (or more) pieces of equipment are connected together with a common ground and a different ground potential exists at each location. This current can cause the connected equipment to experience noise that in turn causes data transmission errors. In the extreme this ground current can cause equipment malfunction or even destruction.

Cabling Recommendations

When connecting the OMG-ULTRA-SIOin a RS-485 network, care should be taken that both ends of the network are not isolated from ground (see Figure 12). This “floating” ground condition could cause the capacitive or inductive coupling of voltages that will cause a break down in the DC to DC converter circuit or in the opto-isolator circuit. This condition will cause data errors and possibly destruction of the receiver circuit.

Isolation

Barrier

A

Isolated

Ultra SIO

DATA+

DATA-

Ground

B

Non

Isolated

Ultra SIO

Figure 11 - OMG-ULTRA-SIOcabling example

OMG-ULTRA-SIO

Page 16

Image 20
Contents User’sGuide Canada MexicoBenelux Czech RepublicContents Figures Factory Default Settings IntroductionOverview What’s IncludedAddress Selection Card SetupPort Enable / Disable 12 11 IRQ SelectionInterrupt Modes E5 E6RS-485 Enable Modes Header E5 & E6, Sharing IRQs with another adapterEcho Echo 422 485 Interface Mode Examples RS-422Line Termination Name FunctionInstallation System InstallationOperating System Installation For Windows Users Other Operating SystemsTechnical Description FeaturesConnector Pin Assignments DB 9 Male Specifications Appendix a Troubleshooting OMG-ULTRA-SIO Appendix B How To Get Assistance RS-485 Appendix C Electrical InterfaceRS-422 What is Ground Loop? Appendix D Ground Loop PhenomenonCabling Recommendations Isolated Ultra SIOAsynchronous Communications Bit Diagram Appendix E Asynchronous CommunicationsAppendix F Silk-Screen Appendix G Compliance Notices WARRANTY/DISCLAIMER Temperature