3.0OPERATION AND DISPLAY PANEL

Operation and Display Panel

3.0OPERATION AND DISPLAY PANEL

The operation and display panel, shown in Figure 17, is on the front panel of the Liebert GXT3 (see Figure 1).

Figure 17 Operation and display panel

Battery Level Indicators

 

Load Level Indicators

Fault Indicator

Bypass Indicator

AC Input Indicator

Inverter Indicator

On/Alarm Silence/Manual

Liebert® GXT3

Battery Test Button

AC Power System
3000VA

Standby/Manual Bypass Button

Battery Indicator

3.1Control Buttons

The operation and display panel has two control buttons: the On/Alarm Silence/Manual Battery Test button and the Standby/Manual Bypass button.

3.1.1 On/Alarm Silence/Manual Battery Test button

The On/Alarm Silence/Manual Battery Test button controls output power to connected load(s) and has three functions (see Table 3).

Table 3

Functions of the On/Alarm Silence/Manual Battery Test button

 

 

 

Function

Operation

Description

 

 

 

 

ON

 

Press the button once for 3 seconds

To start up the UPS

 

 

 

Alarm silence 1

Press the button for at least half a second

To silence alarms 2

Manual Battery Test

Press the button for at least half a second while

To initiate a manual battery test

operating in Mains (AC) Mode with no alarms present.

 

 

 

1. The low battery and bypass reminder alarms cannot be silenced.

2. After the alarm is silenced, UPS will reactivate the alarm system to alert of additional problems.

3.1.2 Standby/Manual Bypass button

The Standby/Manual Bypass button controls output power to connected load(s) and has two functions (see Table 4).

Table 4

Functions of the Standby/Manual Bypass button

 

 

 

Function

Operation

Description

 

 

 

 

Manual Bypass

Press the button once and hold it for about

To initiate a manual transfer of the connected

2 seconds. 1

loads to the internal bypass, if available

 

 

Standby

 

Press the button twice within four seconds while

To shut down the UPS and shut Off all power

 

the UPS is in Manual Bypass or Battery Mode. 2

to the connected loads

 

 

1. If the bypass is not available due to voltage or frequency, pressing this button once will be ignored.

2. Perform all necessary shutdown procedures on connected loads before turning Off the Liebert GXT3.

17