IP-less management requires an NMM in the core chassis, and a media converter with integrated management installed at each remote end of the IP-less managed link. An iConverter10/100M2 plug-in module is installed in the 19-Module chassis, and connected via the fiber link to a standalone 10/100M2 Network Interface Device (NID). This configuration enables the 19-Module master chassis to establish an IP-less management channel between the 10/100M2 link partners. The IP address resides only at the network core, and does not exist on the customer network.

Model Type

NMM

Protocols

IP, UDP, SNMPv1, SNMPv2c, SNMPv3,

Telnet, TCP, FTP, ARP, ICMP, 802.3ah

 

Connectors

RJ-45, DB-9

 

 

Controls

UTP cross-over, Frontplane / Backplane

 

 

LED Displays

Power, Power Supply (3), UTP link,

Master, Slave, Mgt. Poll

 

 

 

Supported MIBs

RFC1155, RFC1156, RFC1157,

RFC1212, RFC1213, OST MIB

 

Dimensions

W:0.85" x D:4.5" x H:2.8"

 

 

Weight

8 oz.

 

 

Compliance

UL, CE, FCC Class A, NEBS 3

Active Controls

Link Propagate/Link Segment

Remote Fault Detection

Module Name

Chassis Name and Number

IP Address

802.3ah OAM Enable

Secure IP-less OAM Enable

Subnet Mask

Gateway

Management Port Disable

Alarm Threshold Setting

Download Software via FTP

Reset Chassis

Telnet

Trap IPs

FTP Enable

Password Selection

Soft Switch Reload

Alarms / Traps

Warm Start

Link Up/Down

Chassis Insertion/Removal

Authentication Failure

DIP-Switch Configuration Change

Software Configuration Change

Temperature Out-of-Range

Power Supply Out-of-Range

Power Supply Insertion/Removal

Chassis Reset

Module Reset

Module Insertion/Removal

Port Link State Change

Redundancy Primary Up/Down

Redundancy Secondary Up/Down

FTP Session Open/Close

Telnet Session Open/Close

Dying Gasp (Power Loss Trap)

Chassis Information

Part Number

Serial Number

Revision

Description

Chassis Status

Power Status

Power Output Voltage

Chassis Temperature

Module Status

Module Power

Link Status

Active Port

Diagnostic Status

Management

Module Information

Module Type

Slot Occupied

Part Number

Serial Number

Configuration

Revision

Ports on Module

User-defined Identifier

Power Requirement

0.32A @ 3.3VDC (typical)

Temperature

Standard:

0 to 50º C

Wide:

-40 to 60º C

 

Storage:

-40 to 80º C

Humidity

5 to 95% (non-condensing)

 

 

Altitude

-100m to 4000m

 

 

MTBF (hrs)

786,000

Model

Description

8000-0

iConverter NMM Module w/ Dying Gasp Support

8080-3

NMM Cascade Cable (3 ft.)

8081-3

NMM Serial Cable (DB-9, 3 ft.)

 

 

Trademarks are owned by their respective companies. iConverter and NetOutlook are registered trademarks of Omnitron Systems Technology, Inc. Specifications subject to change without notice. ©2008 Omnitron Systems Technology, Inc. All rights reserved.

091-18000-001H 12/08

800-675-8410949-250-6510www.omnitron-systems.cominfo@omnitron-systems.com • 140 Technology Dr. • Irvine, CA 92618

Image 2
Contents Network Management Module IConverterIConverter NMM NMM Model Description