Multi-Tech Systems MTD-EVe manual Turning the Device On or Off, Power Draw

Page 7

PRODUCT OVERVIEW

Link Status

On

Description

Continuously lit

Powered on.

 

 

Slow blink (-0.2Hz)

Registered on network.

 

 

Turning the Device On or Off

This USB-powered device does not have a power button. Connecting the device to a computer's USB port turns it on. Disconnecting it or shutting off the computer, turns it off.

Note: When reconnecting the device, use the same USB port that you used when installing drivers. Otherwise, you may need to re-install the driver.

Power Draw

Radio

Cellular Call Box

Average Measured

Peak TX Amplitude

Total Inrush Charge

Protocol

Connection No Data

Current (Amps) at

Current (Amps)

Measured in

 

(Amps)

Maximum Power

 

Millicoulomb

 

 

 

 

 

5 Volts

 

 

 

 

 

 

 

 

 

US Cellular

0.046

0.576

0.636

1.16

800Mhz

 

 

 

 

 

 

 

 

 

US PCS 1900

0.036

0.592

0.648

1.16

Mhz

 

 

 

 

 

 

 

 

 

Note:

Peak Tx: Peak current during CDMA.

Maximum Power: Continuous current during maximum data rate with the radio transmitter at maximum power.

Inrush Charge: Total inrush charge at power on.

QuickCarrierTM USB-D EV-DO MTD-EV3 User Guide

7

Image 7
Contents QuickCarrierTM USB-D EV-DO QuickCarrierTM USB-D EV-DO MTD-EV3 User Guide Contents EMC, Safety, and R&TTE Directive Compliance Documentation MTD-EV3 SpecificationsProduct Overview OverviewSMS Dimensions Link Status LEDTurning the Device On or Off Power DrawSécurité relative aux appareils à radiofréquence RF Safety Notices and WarningsGeneral Safety Radio Frequency RF SafetyPotential interference Device MaintenancePrecautions for pacemaker wearers Interference with Pacemakers and Other Medical DevicesUser Responsibility Account Activation for Cellular Devices Device Phone Number Activation and Carrier Specific InformationCreating a Windows Dial-Up Connection Create a PPP Connection Using LinuxShell Commands Testing Serial PortsQuickCarrierTM USB-D EV-DO MTD-EV3 User Guide Related Documentation Using Command Mode and Online Data ModeBasic Operations Interacting with Your Device OverviewAT+CSQ Verifying Signal StrengthSending Text Messages Checking Network RegistrationReading, Writing, and Deleting Messages Reading Text MessagesSend the message. Enter CTRL+Z Deleting MessagesIndustry Canada Class B Notice EMC, Safety, and R&TTE Directive ComplianceRegulatory Statements CFR Part 15 Regulation Class B DevicesOther Countries International Modem RestrictionsWaste Electrical and Electronic Equipment Statement Environmental NoticesWeee Directive Restriction of the Use of Hazardous Substances RoHS Registration of Substances Reach StatementSubstances of Very High Concern Svhc PBB 成分名称 Chinese hazardous substances IndexText messages Verify communication