Minicom Advanced Systems 116 IP manual Time settings

Page 42

SMART 116 IP

26.5.2 Keyboard (KB)

The Smart 116 IP operates with Windows, Linux, HP UX, Alpha UNIX SGI, DOS, Novell, MAC-USB or Open VMS.

By default the keyboard mode is set to PS for Intel based computers. For the other systems set the KB column as follows:

U1 for HP UX

U2 for Alpha UNIX, SGI, Open VMS

U3 for IBM AIX

To change the setting:

1.On the desired line, press Tab to jump to the KB column.

2.Toggle between the options using the Space bar.

26.5.3 Adding/changing a hotkey (HKEY)

Cascade the Smart 116 IP by connecting another Smart Switch to a Computer port instead of a computer, and then connecting more RICCs to the second Switch.

You must define a different hotkey for the OSD of each Switch. The hotkeys can be any of the choices as set out above on page 39. Use the hotkey when you select the Switch’s port in the first level OSD – the second level’s OSD then appears.

To add/change a hotkey:

1.On the line to which the Switch is connected, press Tab to jump to the HKEY column.

2.Toggle between the options using the Space bar.

26.6 The Time settings

In the Settings window navigate to the Time line and press Enter. The Time settings window appears see Figure 39.

41

Image 42
Contents Smart 116 IP User Guide Table of Contents Logging out Starting a remote session Troubleshooting Safe modeSwitching between computers OSDUpdate software Troubleshooting Technical precautions WelcomeTrademarks Key features IntroductionTerminology System componentsCompatibility Smart 116 IP unitPre-installation guidelines Connector tableLED and button table Avoiding general rack mounting problems Rack mounting the Smart 116 IPConnecting the system Client computer operating systemConnecting to the network RoC/RICCsConnecting a RoC/RICC PS/2 Connecting a RoC/RICC USB Connecting a KVM console Initial settings Default IP addressConnecting the CAT5 cables Connecting the power supplyLogin Logging into the Web interface13.1 LAN Network ConfigurationSSL Certificate notes 13.2 KVM.netAdministration User Settings Saving changesView only AdministratorUser Adding a userAdministration Switch Configuration Deleting a userBlocking a user Administration User Targets Install switch definition fileSecurity Settings Standard security policy High security policyMaintenance Firmware Upgrade Security SSL CertificateRestore Factory Settings Logging outStarting a remote session Remote console windowFull screen mode Taking over a busy remote sessionSwitching to a different server Changing the performance settingsToolbar Adjusting the Video settings BandwidthRefresh Power cycle Keyboard key sequencesClick Start Recording Click Stop RecordingSynchronizing mouse pointers Examples 23.9.3.1 USBAdvanced Mouse Emulation Minicom icon menu features Mouse Emulation Dialog boxTroubleshooting Safe mode Disconnecting the remote sessionEntering Safe mode Restoring factory defaults Safe mode menuReboot Restoring the device firmwareSwitching between computers OSDKeyboard hotkeys OSD settings F2 Navigating the OSDSelecting a computer Supervisor Status S Administrator Status aSecurity User Status UAutoskip Activating password protectionChanging the OSD hotkey Serial port26.4 F7 Defaults Ports settingsEditing the Switch name Time settings Time settings window UsersUsers settings window SecuritySecurity settings window OSD Help window F1Scanning computers F4 Tuning F5Please note Moving the label F6Connecting the RS232 Download cable System requirements for the Update softwareConnecting the Smart 116 IP System Upgrading the Smart 116 IP firmwareInstalling the software Starting and configuring the Update softwareSmart 116 IP Switch Update window Button or Box FunctionVerifying the version numbers Com Port Dialog boxObtaining new firmware Hardware version reportUpdate software Troubleshooting Resetting the Smart 116 IP or RoC/RICCsGet Status Setting default values for the OSDCommunication Error message Electricity failureTechnical specifications Video resolution and refresh rates SafetyUser guide feedback Regional Offices
Related manuals
Manual 67 pages 7.17 Kb

116 IP specifications

Minicom Advanced Systems has made significant strides in the realm of data center infrastructure solutions, particularly with the introduction of the Minicom Advanced Systems 116 IP. This device is designed primarily for providing advanced control and management for IT professionals seeking robust and efficient ways to manage access to their server rooms and IT environments.

One of the standout features of the Minicom Advanced Systems 116 IP is its support for IP-based KVM (Keyboard, Video, Mouse) switching. This technology allows users to remotely access and control multiple servers from a single workstation, eliminating the need for physical access to each machine. This is particularly beneficial in large data center environments, where time and space efficiency are critical.

The 116 IP model offers a high-resolution video output, supporting resolutions up to 1920x1200. This ensures that users can maintain the clarity of visual data while managing their systems remotely. The system is compatible with a myriad of operating systems, including Windows, Linux, and Mac, which makes it versatile for various IT environments.

Security is a paramount consideration for any organization dealing with sensitive data. The Minicom 116 IP incorporates advanced security features, including user authentication protocols and encryption mechanisms. This ensures that only authorized personnel can access the systems, reducing the likelihood of data breaches and unauthorized access.

Moreover, the device is equipped with hot-plugging capabilities, allowing users to add or remove servers without needing to power down the system. This feature enhances uptime and productivity, as administrators can make changes without disrupting ongoing operations.

In addition to its technical facets, the Minicom 116 IP is designed with user experience in mind. It features a user-friendly interface that simplifies the management of multiple servers, making it easier for IT staff to navigate between different machines.

Finally, the device is built for scalability, allowing organizations to expand their IT infrastructure as they grow. This flexibility means that the Minicom Advanced Systems 116 IP can adapt to increasing demands without necessitating a complete overhaul of existing systems.

In summary, the Minicom Advanced Systems 116 IP presents a suite of advanced features, including high-resolution output, robust security protocols, hot-plugging capabilities, an intuitive user interface, and scalable architecture, making it an ideal solution for modern data center management needs.