3.4 Making Trunk Connections

Two switch units can be cascaded together through any regular switched data port on each unit when a port expansion is required. However, the transfer bandwidth between the two cascaded ports is limited to 200Mbps full duplex. To increase the bandwidth for the connection between two switch units, a trunking function is implemented on the switch unit for this purpose. Normal data ports can be configured optionally as trunking ports through the network management operation.

Two or more trunking ports composes one trunk. Two switch units can be cascaded through one trunk. The aggregated bandwidth of one trunk can be up to 800Mbps, if 4 trunking ports are used for one trunk.

Refer to the software operation manuals in the supplied CD-ROM for more information about how to configure a data port as a trunking port.

The following figure illustrates an example of 4-port trunk connection between switch A and switch B. The Port 3, 4, 5 and 6 of switch A are configured as trunking ports and compose one trunk. The Port 5, 6, 7, and 8 of switch B are configured as trunking ports and compose one trunk. The aggregated band width of the trunk is 800Mbps.

Switch A - Trunk: Port #3 - #6

One trunk

 

 

 

 

 

 

 

 

All crossover UTP cables

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100 meters maximum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch B - Trunk: Port #5 - #8

Rules :

1.One switch can be configured to have up to 4 trunks and each trunk can be composed of up to 4 trunking ports. All port members of one trunk must locate in same group, either in group [port 1-port 12] or in group [port 13 - port 24].

2.One trunking port can only belong to one trunk.

3.Only one trunk can exist between two switch units.

4.Crossover UTP cables should be used at the same time for one trunk connection. The length of each cable can be up to 100 meters.

5.When the switched data ports are enabled as trunking ports, they can only serve trunking function, but no other data function.

6.Since the trunking is proprietary, the switches do not support trunk connection to other brands switches.

11

Image 14
Contents MIL-S3570 Regulatory Approval Table of Contents High Port-count and High Bandwidth Igmp MIB Ieee 802.1P/Q GARP/GVRP Packing List Mounting the Switches Desktop Mounting 1000BASE-FX Switch can support connections to the following devices Connected Device UTP Cable Used & Maximum Length MT-RJ Full duplex One trunk All crossover UTP cables Meters maximum Page Virtual LAN Vlan LED State Indication Management Support GVRP, Igmp DCD RXD TXD DTR GND DSR RTS CTSHttp//xxx.xxx.xxx.xxx Rmon MIBContact the MiLAN web site for available software version Division of Digi International