MGE UPS Systems Network Shutdown Module V3 user manual Status, Values

Page 22

www.apc.com / www.mgeups.com

ω Contact / Location:

The device contact. (value of syscontact object or can also be configured in the

 

Device page).

 

The device location. (value of syslocation object or can also be configured in the

 

Device page).

Status

 

ω Communication:

Device communication status (OK / Network Communication Failure / device

ω Power source:

Communication Failure).

AC Power / Battery.

ω Battery:

Charging / Discharging / Battery fault.

ω Output:

Main output status (ON/OFF/Internal Failure/On Automatic

 

Bypass/Manual By Pass/Overload).

 

Or output outlet status (ON/OFF).

Values

The outlet group that powers the device is highlighted in bold

 

ω Output Load Level:

The output load level of the device.

ω Battery capacity:

Battery capacity of the device.

ω Backup time:

The device remaining backup time.

Note that this view is impacted when any device status is affected.

T H E U N I N T E R R U P T I B L E P O W E R P R O V I D E R

Network Shutdown Module V3 – User Manual - APC # 990-3630 (MGE # 34 003 934 XU / AB)

Page 21/66

Image 22
Contents Network Shutdown Module Network Shutdown Module Table of Contents Glossary Acknowledgements Overview Introduction to the MGE’s Network SolutionFunctions of MGE’s Network offering Monitoring the UPSs over the network Protecting the computers / servers UPSs in parallel powering several serversUPS that powers servers with load-shedding function Shutdown modulesSelect Network Architecture Connecting the UPSConnecting to the Network Network Management Card or ProxyNetwork Performances Connection with Network Management ProxyHardware Pre-requisites Electrical and Network Connections InstallationConnection steps Software Installation Pre-requisites On the System Hosting « Network Shutdown Module V3 »If you use a Firewall with all ports closed by default Configuration-Power devices screen Quick StartSoftware Installation Procedure Configuration- Power device screenFileName -install -silent -agentName ‘172.17.1.2’ Uninstalling the Network Shutdown Module Application deployment and silent installation advancedNetwork Shutdown Module application deployment Powershare outlets and load shedding Minimal configuration stepsIP address of the UPS that powers your server IntroductionLoad shedding configuration on UPS powershare outlets RemarkUser accounts configuration Users accounts configurationEnter the User Login and the User password twice Use Local accessRemote access Monitoring the server and the UPSsServer and UPS supervision Section concerning the UPS that powers the protected serverSection « Information on the protected server» Status ValuesIcon Event status System and UPS event logUPS Events list Event listOr communication lost between the device and the Card/Proxy Simple Tests Installation is in correct running orderTest the communication with the UPS TestAdvanced tests Messages in verbose modeStart and stop the Shutdown Module advanced Event logConfigure system parameters Other Configuration possibilitiesSystem parameters configuration Shutdown timer Shutdown when timer reaches Shutdown ConfigurationUse central configuration provided by Management Card/Proxy Shutdown durationMessage broadcast to the administrator Message broadcast to usersChecking for Upgrades Check for upgrade windowEvents and actions advanced configuration Events / actionsRecommendations Multi-UPS SystemsPresentation Network Shutdown Module V3 makes it possible32/66 Information on the protected server section Power devices List sectionServer and multi-UPS supervision Multi-sources Information sectionCreate a multi-UPS configuration Multi-UPS configurationMulti-UPS Mode Compatibility list Single UPS Mode compatibilityAppendix UPSs in Hot-Standby UPSs through Static Transfer SwitchUPSs powering a server with redundant power supplies UPSs in serial redundancyServers with single power supply and Multiple STS Simple associations of the previous configurationsServers with triple power supplies Configurations not supported Electrical drawing Description Examples of Multi UPS configurationsMulti-UPS Systems and Event Management NecessaryFirst example Application deployment and silent installationIntroduction Second exampleCustomized installation package Build customized packageInstall the Shutdown Module in silent mode Example of secured deployment script for LinuxAdvanced installation options UninstallDiagrams below present the sequence Single UPS Shutdown Sequence100 sec ExampleMachine 180 secUPS1 Additional information on events and actions Action settings TabAction settings tab Possible operations on actionsCustomized actions Standard actionsAction name Role 1.3 «System Shutdown» Action Shutdown parametersExecute Action Type Select ExecuteConfigure the send email action 1.5 «Send email» ActionOr by the utility Events TabEvents Tab Or the output load is correctOr The installation has one or several redundancy source Or end of bypass alarmUPS is restored Or Communication between Network Management Card/ProxyTest tab Test TabAction parameters execute and send email Action parameters execute and send emailSoftware utilities Parameter DescriptionLocation PresentationUse Instructions for use During Installation FAQ and Error messagesDuring use Solutions to build a customized package after reboot Html pagesSolution NMS Network Management System IP address / nameNetwork Management Proxy Network Shutdown ModuleSQLite Pi3Web AcknowledgementsPHP OpenSSL 64/66 Lighttpd WxWidget

Network Shutdown Module V3 specifications

The MGE UPS Systems Network Shutdown Module V3 is an advanced solution designed to manage the safe shutdown of critical IT infrastructures during power outages. As businesses increasingly rely on electronic systems for their operations, ensuring data integrity and preventing hardware damage during unexpected shutdowns is paramount. The Network Shutdown Module V3 provides a seamless response to power loss events, ensuring that systems are properly powered down, minimizing the risk of data loss and equipment failure.

One of the key features of the MGE UPS Systems Network Shutdown Module V3 is its multi-platform support, which allows it to be compatible with various operating systems, including Windows, Linux, and Unix. This versatility ensures that organizations can integrate the module into their existing IT environments without the need for extensive modifications. Additionally, the software can manage multiple servers simultaneously, making it an ideal solution for data centers and enterprises with distributed IT systems.

The module employs advanced communication protocols, including SNMP and Web-based interfaces, facilitating easy integration with network management systems. This feature enables IT administrators to monitor UPS status in real-time, allowing for proactive responses to potential power issues. Furthermore, the Network Shutdown Module V3 can send notifications to users and administrators via email or SNMP traps, keeping everyone informed during critical power events.

Another significant benefit of the Network Shutdown Module V3 is its user-friendly configuration options. The intuitive web interface simplifies setup and management, allowing users to customize shutdown settings according to their specific needs. The module can be configured to initiate a graceful shutdown sequence that saves work in progress and performs necessary tasks, such as database backups, before the systems power down.

The Network Shutdown Module V3 is built with robust security features to protect sensitive data during power interruptions. It includes encryption for data transmission and access controls to ensure that only authorized personnel can make changes to the shutdown settings. This focus on security helps organizations comply with industry standards and regulations, further enhancing the module's value.

In conclusion, the MGE UPS Systems Network Shutdown Module V3 is an essential component for any organization seeking to safeguard its electronic systems against power failures. With its multi-platform support, advanced communication capabilities, user-friendly interface, and robust security features, this module ensures that businesses can maintain operational continuity and protect valuable data even in the face of unexpected power disruptions.