LOREX Technology DHU500 SERIES installation manual PTZ Menu, Off

Page 37

SECTION 4

System Set

PTZ Menu

Pan / Tilt / Zoom control (for Pelco D or Pelco P Model Cameras only)

PTZ (enter Password)

 

 

 

 

 

 

Setup PTZ

 

 

 

 

 

 

 

Channel:

1

 

 

 

 

 

 

ID:

OFF

 

 

 

 

 

 

Protocol:

PELCO-P

 

 

 

 

 

 

Baud Rate:

2400

 

Pan/Tilt/Zoom

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Focus

 

 

 

PTZ Controller Set

 

Setup

 

 

 

 

 

 

 

ID:

1

 

PTZ Controller Set

 

 

 

 

 

 

 

 

 

Model:

TB-CN

 

 

 

 

 

 

 

 

 

 

 

 

Baud Rate:

9600

 

 

 

 

 

 

Save & Exit

 

1.PAN / TILT / ZOOM: Accesses the PTZ Control for a camera. Press the K and L buttons to highlight, and press the SEL button to access PTZ controls:

LEFT/RIGHT - Pans the camera LEFT/RIGHT

UP/DOWN - Tilts the camera UP/DOWN

VOL UP/DOWN - Zooms the camera IN/OUT

SEL/MENU - Stops viewing / Exits viewing

2.FOCUS: Accesses the Focus Control for a camera. Press the K and L buttons to highlight, and press the SEL button to access FOCUS controls:

UP/DOWN - Focuses NEAR/FAR

SEL/MENU - Stops/Exits Menu

3.SETUP: Setup of the PTZ Cameras. Press the K and L buttons to highlight, and press the SEL button to enter the SETUP menu:

CHANNEL: Select the PTZ camera location (Channel 1-4, 1-8, or 1-16 depending on model)

ID: Set the camera ID (1-256, or OFF).

Protocol: Select the PTZ Protocol (PELCO-D or PELCO-P)

Baud Rate: Select the Baud Rate for the Camera (2400, 4800 or 9600 BPS)

SAVE & EXIT: Saves any changes, and exits to the previous menu.

Setup PTZ

 

Channel:

1

ID:

OFF

Protocol:

PELCO-P

Baud Rate:

9600

 

 

Revision 1.0

37

Image 37
Contents Installation Manual Thank You Installation Important SafeguardsServiceUse General Precautions General PrecautionsPage Table of Contents USB Updating the DVR Firmware Network Connectivity DVR Network SettingsFeature List Technology DHU500 Series DVR FeaturesPacking Detail Section Packing DetailLocation and Control Number / Letter PAD DHU500 Series FrontOnly one channel audio available on the 4-Channel DVR Model DHU500 Series Back 9 10 Page Turning on for the First Time Starting the DVR Self Test Screens Powering Off the DVR/Stopping RecordingStarting the DVR Quad Display Main Menu Control OSD ON/OFF Main Menu TreePTZ Display Set Menu Tree Display SetCamera Covert Monitor Set 4 CH onlyCamera Name Set Display Sequence 8/16 CH Only OSD ON/OFFEvent Clear Set Display SequenceRecording Set Menu Tree Recording SetHigh MEDCH1 Motion Sensitivity Normal Recording Global ParametersMotion Recording Schedule Recording Recording ON/OFF System Set Password MismatchMM-DD-YYYY DST OFF TB-CNMM-DD-YYYY DD-MM-YYYY YYYY-MM-DD BasicDisk Format Password ChangeClient Account Program UpdateAuto Delete Set PTZ Menu Ddns Set Network SetDdns YES Dhcp IP SetEvent Notification Menu Tree Event NotificationEmail Report Email RegistrationNotification Out Compatible USB Devices USB Updating the DVR FirmwarePage Network Connectivity Network Connectivity DVR Network Settings Network Example Router Port ForwardingNavigate to http//DDNS.digimerge.net Setting Up Your Ddns AccountSetting Up Your Ddns Account Setting up Ddns on the DVR Page Troubleshooting Check TroubleshootingSection Page DVR Specifications DVR Specifications Connecting MOTION/ALARM Device Installing a Sensor Connecting Motion / Alarm DeviceDVR Limited Warranty It’s all on the web