The component height on the top and bottom of the board conforms to the PCI Specification.
1.1.2.2 Electrical Characteristics
The LSI20860 maximum power requirement, including SCSI TERMPWR, under normal operation is:
Table 1.1 Maximum Power Requirements
+ 5 V DC
±5%
1.5 A
Over the operating range 5 °C to 55 °C
Under abnormal conditions such as a short on SCSI TERMPWR, +5 V current may be higher. At temperatures of at least 25 °C a current of 4 A is sustained no longer than 30 seconds before the
The PCI PRSNT1/ and PRSNT2/ pins are set to indicate a 7.5 W maximum configuration.
1.1.2.3 Thermal, Atmospheric Characteristics
The board is designed to operate in an environment defined by the following parameters:
∙Temperature range: 5 °C to 55 °C (dry bulb)
∙Relative humidity range: 5% to 90% noncondensing
∙Maximum dew point temperature: 32 °C
∙Storage Temperature: −40 °C to +85 °C with 0 to 95% RH noncondensing 10 °C
1.1.2.4Electromagnetic Compliance
The board is designed and implemented to minimize electromagnetic emissions, susceptibility, and the effects of electromagnetic discharge. The board meets the requirements of FCC Class B and CISPR 22 limits and is marked with the FCC Class B Declaration of Conformity Symbol. It also carries the CE mark.