Maretron NBE100 Technical Specifications, Certifications, NMEA 2000 Parameter Group Numbers PGNs

Page 11
5 Technical Specifications

®

5 Technical Specifications

As Maretron is constantly improving its products, all specifications are subject to change without notice. Maretron products are designed to be accurate and reliable; however, they should be used only as aids to navigation and not as a replacement for traditional navigation aids and techniques.

Certifications

Parameter

NMEA 2000® Standard

Maritime Navigation and Radiocommunication Equipment & Systems

Maritime Navigation and Radiocommunication Equipment & Systems

FCC and CE Mark

Comment

Level A+

IEC 61162-3

IEC 60945

Electromagnetic Compatibility

NMEA 2000® Parameter Group Numbers (PGNs)

Description

PGN #
PGN Name
Default Rate

Response to Requested

126464

PGN List (Transmit and Receive)

N/A

PGNs

126996

Product Information

N/A

 

126998

Configuration Information

N/A

Protocol PGNs

059392

ISO Acknowledge

N/A

 

059904

ISO Request

N/A

 

060928

ISO Address Claim

N/A

 

065240

ISO Address Command

N/A

 

126208

NMEA Request/Command/Acknowledge

N/A

Maretron Proprietary PGN’s

126720

Configuration

N/A

Electrical

Parameter

Value

Operating Voltage

9 to 16 Volts

Power Consumption

<150mA

Load Equivalence Number (LEN)

3

Reverse Battery Protection

Yes

Load Dump Protection

Yes

Comment

DC Voltage

Average Current Drain

NMEA 2000® Spec. (1LEN = 50 mA) Indefinitely

Energy Rated per SAE J1113

Mechanical

Parameter

Value

Size

3.11” x 3.46” x 1.38”

 

(79mm x 88mm x 35mm)

Weight

8 oz. (227 g)

Comment

Including Flanges for Mounting

Revision 1.0

Page 7

Image 11
Contents Maretron, LLP 9014 N. 23rd Ave #10 RevisionPage Revision Copyright 2011 Maretron, LLP All Rights ReservedRevision Revision HistoryNBE100 Users Manual PageTable of Figures Table of ContentsThis page intentionally left blank 1.1 Firmware Revision 1.2 NBE100 Features1.3 NBE100 Accessories 1 Introduction2.2 Choosing a Mounting Location 2 Installation1.4 Quick Install 2.1 Unpacking the BoxFigure 1 - Mounting the NBE100 2.4 Connecting the NBE1002.3 Mounting the NBE100 2.4.1 NMEA 2000 ConnectionFigure 2 - NMEA 2000 Connector Face Views 2.5.1 Device Instance 2.5 Configuring the NBE100Figure 3 - NBE100 Connection Diagram 2.4.2 Checking Connections2.5.3.1 Restore Factory Defaults 3 Maintenance4 Troubleshooting 2.5.3 Advanced Configuration…Electrical 5 Technical SpecificationsCertifications NMEA 2000 Parameter Group Numbers PGNssupport@maretron.com 6 Technical SupportEnvironmental Figure 4 - Mounting Surface Template 7 Installation TemplateWarranty Return Procedure 8 Maretron 2 Year Limited Warranty