Liebert LDM user manual Safety Instructions

Page 5

SAFETY INSTRUCTIONS

! WARNING

As with all types of electrical equipment, dangerous voltages exist within the equipment where the Liebert Distribution Monitor (LDM) is installed. For maximum safety, ensure power is removed and circuit breakers/disconnects are tagged/locked out per all applicable national, state and local electrical codes prior to working inside equipment.

The area around the equipment must be free of any debris or standing water.

All power and control wiring must be installed by a qualified electrician in accordance with the NEC and all applicable national, state and local codes.

ONLY qualified service personnel should perform maintenance and/or service on the Liebert LDM. When performing maintenance and/or service on any component, verify test equipment is insulated and has been inspected prior to use.

To avoid damage to the circuit boards, personnel handling these components should be wearing an Electrostatic Discharge strap or other approved protective device.

When replacing or installing a solid core Current Transformer (CT), power must be removed from equipment to prevent damage to the CT and/or circuit board. If the CT is a split-core design, follow proper electrical safety procedures.

These safety precautions are to be used in conjunction with NEC and local/state electrical code.

1

Image 5
Contents Liebert Distribution Monitoring LDM Page Table of Contents Tables Safety Instructions Following abbreviations are used in this manual Glossary of AbbreviationsProduct Overview Major Components Branch Circuit Monitoring Control Board BCBCT matrix for the Liebert LDM Part Number Description Phase CT Ground CT Neutral CTPanel Board Voltage-Current Board Pbvi Branch Circuit Monitoring Sensor Module BSM Power Supply Assembly with EMI FilterLarge Interface Board LIB Connecting Panelboards a and B Installing a BSM CT Module AssemblyInstallation Installing a Solid-Core Current Transformer Pin Wiring Connecting a Current Transformer to the Pbvi BoardConfiguration 1 Four Modules Connector P3 a Wiring configuration of large branch circuit breakersConnector P4 B CT Table for Pbvi BoardLB11 LB12 LB13 First Breaker Second Breaker Connecting a Current Transformer to the LIB BoardFour CTs Ground CT Three phases Neutral CT Table for LIB Wiring configuration for LIBWiring configuration for LIB2 Parameters monitored for breakers OperationAlarm conditions and factory setpoints AlarmsModbus Connection LDM Setup Port ConnectionCommunication Downloading the Software Using the Monitor ToolStarting the Monitor Tool COM port ConnectMonitor menu options Monitor Menu OptionsPanel Status and Real-Time Clock Monitor mode buttons Mode ButtonsMain Breaker Status Breaker StatusStarting the Configuration Program Using the Configuration ToolTo Connect via COM Port To Work in Offline Mode COM port Work OfflineOverview of main Configuration window Main Configuration Window OverviewSave the Configuration File to Disk Load a Configuration File from DiskInstall Configuration Changes in the Unit Panel Breakers view Auxiliary Breakers view Select Panel to ViewSelect Breakers to View Edit the Liebert LDM Unit Properties Edit the Panel Properties or Set a PasswordParameter Description To make a change Edit the Breaker PropertiesAdding a Circuit Breaker Add or Delete a Circuit BreakerAdding a Subfeed Breaker Delete a Breaker Upgrading the Firmware Operation Progress Failed = Electrical SpecificationsTroubleshooting / Faqs Page Iti Ne tTi n That

LDM specifications

Liebert LDM (Liebert Digital Monitor) is an advanced thermal management solution, specifically designed to enhance the performance and reliability of critical infrastructure systems. This innovative product from Vertiv caters to the growing demand for efficient cooling solutions in data centers, telecommunication sites, and other facilities requiring precise environmental control.

One of the standout features of the Liebert LDM is its advanced monitoring capabilities. The device is equipped with numerous sensors that measure crucial parameters, including temperature, humidity, and airflow. These measurements help operators analyze the cooling efficiency of their systems and ensure optimal operating conditions. The real-time data provided by the Liebert LDM allows for proactive maintenance, reducing the risk of equipment failure due to overheating or improper humidity levels.

The Liebert LDM employs sophisticated algorithms to optimize cooling performance. Its ability to analyze data trends plays a vital role in preventing hot spots and ensuring uniform cooling throughout the facility. This technology enhances the overall efficiency of cooling systems, which translates into reduced energy consumption and lower operating costs.

Another key characteristic of the Liebert LDM is its modular design. This flexibility allows users to scale their monitoring capabilities based on the size and complexity of their cooling setup. Whether a small server room or a large data center, the Liebert LDM can be tailored to meet specific operational needs.

Integration is another core advantage of the Liebert LDM. It seamlessly connects with various management systems and can be monitored through user-friendly interfaces. This interoperability ensures that facility managers can easily track performance metrics and integrate the Liebert LDM into their existing operational protocols.

The construction of the Liebert LDM is designed with durability and longevity in mind. Built to withstand the rigors of commercial use, the device features robust housing and weather-resistant components. This resilience ensures that the Liebert LDM remains a reliable tool within critical environments.

In summary, the Liebert LDM is a sophisticated thermal management solution combining precision monitoring, energy efficiency, modular flexibility, seamless integration, and robust design. As technology evolves, maintaining optimal environmental conditions becomes increasingly crucial. The Liebert LDM addresses these challenges, ensuring that critical systems operate reliably and efficiently in the face of rising demands.