Liebert LDM user manual Branch Circuit Monitoring Control Board BCB, Major Components

Page 8

Major Components

3.0MAJOR COMPONENTS

3.1Branch Circuit Monitoring Control Board (BCB)

The BCB is the main processing and storage circuit board of the Liebert LDM. It is a DSP-based logic controller with internal flash memory and non-volatile memory. The BCB also includes a battery- backed real time clock.

One of the power parameters, kilowatt-hours (kWh), data is accumulated on this board for the panel- board mains, subfeeds and each branch circuit breaker. A Modbus command is provided to reset all accumulated power usage.

4

Image 8
Contents Liebert Distribution Monitoring LDM Page Table of Contents Tables Safety Instructions Glossary of Abbreviations Following abbreviations are used in this manualProduct Overview Branch Circuit Monitoring Control Board BCB Major ComponentsCT matrix for the Liebert LDM Part Number Description Phase CT Ground CT Neutral CTPanel Board Voltage-Current Board Pbvi Branch Circuit Monitoring Sensor Module BSM Power Supply Assembly with EMI FilterLarge Interface Board LIB Connecting Panelboards a and B Installing a BSM CT Module AssemblyInstallation Installing a Solid-Core Current Transformer Connecting a Current Transformer to the Pbvi Board Pin WiringWiring configuration of large branch circuit breakers Configuration 1 Four Modules Connector P3 aConnector P4 B CT Table for Pbvi BoardLB11 LB12 LB13 First Breaker Second Breaker Connecting a Current Transformer to the LIB BoardFour CTs Ground CT Three phases Neutral Wiring configuration for LIB CT Table for LIBWiring configuration for LIB2 Operation Parameters monitored for breakersAlarms Alarm conditions and factory setpointsModbus Connection LDM Setup Port ConnectionCommunication Using the Monitor Tool Downloading the SoftwareStarting the Monitor Tool COM port ConnectMonitor menu options Monitor Menu OptionsPanel Status and Real-Time Clock Mode Buttons Monitor mode buttonsMain Breaker Status Breaker StatusUsing the Configuration Tool Starting the Configuration ProgramTo Connect via COM Port To Work in Offline Mode COM port Work OfflineMain Configuration Window Overview Overview of main Configuration windowSave the Configuration File to Disk Load a Configuration File from DiskInstall Configuration Changes in the Unit Panel Breakers view Auxiliary Breakers view Select Panel to ViewSelect Breakers to View Edit the Panel Properties or Set a Password Edit the Liebert LDM Unit PropertiesEdit the Breaker Properties Parameter Description To make a changeAdd or Delete a Circuit Breaker Adding a Circuit BreakerAdding a Subfeed Breaker Delete a Breaker Upgrading the Firmware Operation Progress Failed = Specifications ElectricalTroubleshooting / Faqs Page Ne t ItiTi n That

LDM specifications

Liebert LDM (Liebert Digital Monitor) is an advanced thermal management solution, specifically designed to enhance the performance and reliability of critical infrastructure systems. This innovative product from Vertiv caters to the growing demand for efficient cooling solutions in data centers, telecommunication sites, and other facilities requiring precise environmental control.

One of the standout features of the Liebert LDM is its advanced monitoring capabilities. The device is equipped with numerous sensors that measure crucial parameters, including temperature, humidity, and airflow. These measurements help operators analyze the cooling efficiency of their systems and ensure optimal operating conditions. The real-time data provided by the Liebert LDM allows for proactive maintenance, reducing the risk of equipment failure due to overheating or improper humidity levels.

The Liebert LDM employs sophisticated algorithms to optimize cooling performance. Its ability to analyze data trends plays a vital role in preventing hot spots and ensuring uniform cooling throughout the facility. This technology enhances the overall efficiency of cooling systems, which translates into reduced energy consumption and lower operating costs.

Another key characteristic of the Liebert LDM is its modular design. This flexibility allows users to scale their monitoring capabilities based on the size and complexity of their cooling setup. Whether a small server room or a large data center, the Liebert LDM can be tailored to meet specific operational needs.

Integration is another core advantage of the Liebert LDM. It seamlessly connects with various management systems and can be monitored through user-friendly interfaces. This interoperability ensures that facility managers can easily track performance metrics and integrate the Liebert LDM into their existing operational protocols.

The construction of the Liebert LDM is designed with durability and longevity in mind. Built to withstand the rigors of commercial use, the device features robust housing and weather-resistant components. This resilience ensures that the Liebert LDM remains a reliable tool within critical environments.

In summary, the Liebert LDM is a sophisticated thermal management solution combining precision monitoring, energy efficiency, modular flexibility, seamless integration, and robust design. As technology evolves, maintaining optimal environmental conditions becomes increasingly crucial. The Liebert LDM addresses these challenges, ensuring that critical systems operate reliably and efficiently in the face of rising demands.