Liebert 1500, 3000, 4000, 6000 A user manual Table of Contents

Page 3

TABLE OF CONTENTS

1.0 ABOUT THIS DOCUMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.1 Purpose of This Document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.2 Applicability of This Document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

2.0 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.1 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

2.2 Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

2.3 Control and Distribution Cabinets - Typical Configurations. . . . . . . . . . . . . . . . . . . . . . . 4

3.0 SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

3.1 Framework . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

3.1.1 Mechanical Specifications of a Cabinet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 3.1.2 Electrical Specifications of the Cabinets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

3.2 Conventional Controller. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

3.2.1 Mechanical Specifications of the Conventional Controller . . . . . . . . . . . . . . . . . . . . . . . . . 7 3.2.2 Electrical Specifications of the Conventional Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

3.3 Distribution Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

3.3.1 Fuse Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 3.3.2 Circuit Breaker Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

3.4 Externally Mounted Battery Return Busbar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

3.4.1 Mechanical Specifications of the External Battery Return Busbar . . . . . . . . . . . . . . . . . 18 3.4.2 Electrical Specifications of the External Battery Return Busbar . . . . . . . . . . . . . . . . . . . 18

3.5 Terminating Assemblies (Optional). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 3.6 MPS300 and MPA100 Power Shelves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

3.6.1 Mechanical Specifications of the MPS300 and MPA100 Power Shelves . . . . . . . . . . . . . 20 3.6.2 Electrical Specifications of the Power Shelves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

3.7 Rectifiers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

3.7.1 Helios Rectifier 100/48 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 3.7.2 Helios Rectifiers 200I/48 and 200E/48 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 3.7.3 Electrical Specifications of the Helios Rectifiers 200I/48 and 200E/48. . . . . . . . . . . . . . . 24 3.7.4 Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

3.8 Helios Monitor 3000/48 (Optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

3.8.1 Mechanical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 3.8.2 Electrical Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

3.9 600 A and 1200 A Battery Disconnect Unit (Optional) . . . . . . . . . . . . . . . . . . . . . . . . . . 25 3.10 AC Junction Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

3.10.1 Mechanical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 3.10.2 Electrical Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

i

Image 3
Contents Helios DC System 4000/48 Page Table of Contents Maintenance OperationReference Documents 7.0 List of Terms Figures Tables Applicability of This Document Purpose of This DocumentRectifier cabinets Main cabinet Aux dist. cabinet DescriptionApplications Control and Distribution cabinet 1200A Rectifier cabinet Control and Distribution Cabinets Typical ConfigurationsRectifier Cabinet Capacity Type Qty Cabled top or bottom Rectifier cabinetsControl and distribution cabinets Auxiliary distribution cabinetsFramework type Height Depth Width Weight Mechanical Specifications of a CabinetElectrical Specifications of the Cabinets Mechanical specifications of the cabinet emptyHeight Depth Width Weight Mechanical Specifications of the Conventional ControllerElectrical Specifications of the Conventional Controller Mechanical specifications of the Conventional ControllerFuse sizes available for the 20 QFF 0-5 a fuse panels Fuse Panels Mechanical specifications of the fuse panelsMechanical specifications of the fuse panels Distribution PanelsFront view of the 16 QFF 0-5 a & 6 TPN 5-30 a fuse panels Front view of the 16 QFF 0-5 a & 12 ABS 5-30 a fuse panelsFuse sizes available for the 4 RS100P 70-100 a fuse panels Fuse sizes available for the 8 TPN 5-30 a fuse panelsFuse sizes available for the 4 TPL 225-600 a fuse panels DC power TPLFuse sizes available for the 18 TPS 1-70 a fuse panel DC power TPSFuses Busbar Panel number Quantity Capacity Electrical specifications of the fuse panelsElectrical specifications of the fuse panels Mechanical specifications of the circuit breaker panelsNominal CPC Std Trip CPC Mid Trip Current Front view of the 24 Plug-In 1-100 a circuit breaker panelNominal current Front view of the 4 70-250 a circuit breaker panelFront view of the 2 400 a circuit breaker panel Electrical specifications of the circuit breaker panels Electrical specifications of the circuit breaker panelsExternally Mounted Battery Return Busbar Mechanical specifications of a single laminationLength Width Thickness Perspective view of the a terminating assemblies Terminating Assemblies OptionalShelf model Height Depth Width Weight MPS300 and MPA100 Power ShelvesElectrical Specifications of the Power Shelves Mechanical specifications of the Helios Rectifier 100/48Rectifiers Electrical specifications of the Helios Rectifier 100/48 Electrical specifications of the Helios Rectifier 100/48Front view of the Helios Rectifiers 200I/48 and 200E/48 Standards Total harmonicDistortion THD Mechanical specifications of the Helios Monitor 3000/48 600 a and 1200 a Battery Disconnect Unit OptionalMechanical Specifications Electrical SpecificationsMechanical specifications of fully equipped power cabinets Overall Power System SpecificationsMechanical Specifications of Fully Equipped Power Cabinets Mechanical specifications of the AC junction boxTransportation Environmental Specifications OperatingElectromagnetic compliance EMC Electrostatic discharge ESD immunityFront Panel Visual indicatorsVisual indicators GeneralPotentiometers Transmitted alarmsAlarm Description PotentiometersDIP switch modules SwitchesDIP switches SwitchesTest points FusesTest points FuseTerminal blocks Rear PanelTB3 TB4 TB1 TB2 Connectors Rectifiers 600 a and 1200 Battery Disconnect Units Optional Cleaning Helios Monitor 3000/48 Controller and RectifiersCalibration Storage Fan unit replacement Air filter replacementFault diagnosis TroubleshootingAddition or Replacement of a Rectifier Addition / Replacement ProceduresAdding a Helios Rectifier 200I/48 or 200E/48 Adding a Helios Rectifier 100/48AC connections in a Helios Rectifier 200E/48 Cover Rect Replacing a Helios Rectifier 100/48 Replacing a RectifierReplacing a Helios Rectifier 200I/48 or 200E/48 Removal of the old string Adding or Replacing a Battery StringReplacement of a Distribution Fuse Block or Circuit Breaker Replacing a Cabinet Alarm LampReplacing a distribution circuit breaker Manual No Description Reference DocumentsGRD or Grnd AC or acDC or dc Ft-lbPsi In.-lbList of Terms Technical Support 1500, 3000, 4000 & 6000 a DC Power System
Related manuals
Manual 76 pages 7.19 Kb Manual 76 pages 48.63 Kb

1500, 6000 A, 4000, 3000 specifications

The Liebert 3000 is a cutting-edge power protection solution designed to provide reliable and efficient backup power for critical applications. This uninterruptible power supply (UPS) system is engineered to safeguard sensitive electronic equipment from power disturbances, ensuring uninterrupted operations in data centers, telecommunications, and industrial environments.

One of the standout features of the Liebert 3000 is its high-efficiency design. With an efficiency rating of up to 94%, the system minimizes energy loss, resulting in lower operational costs and a reduced carbon footprint. This is particularly important in today's environmentally conscious climate, as organizations strive to meet sustainability goals while maintaining top-tier performance.

The Liebert 3000 employs advanced technologies to enhance its functionality. It incorporates online double-conversion technology, which provides a continuous supply of clean and regulated power. This technology ensures that connected loads receive stable voltage and frequency, shielding them from voltage spikes, sags, and outages. Additionally, the UPS offers features such as automatic battery testing, which helps ensure peak battery performance and reliability.

Another key characteristic of the Liebert 3000 is its modular design, allowing for flexible scalability. This means that organizations can easily expand the capacity of their UPS system as their power needs grow, without the need for extensive system overhauls. The modular architecture also facilitates simplified maintenance and reduces downtime, as individual modules can be serviced without interrupting power to the critical load.

The system is equipped with comprehensive monitoring and management capabilities. The Liebert 3000 provides real-time data on power usage, battery status, and system performance, enabling facility managers to make informed decisions and proactively address potential issues. The integration of remote management tools allows for seamless monitoring from anywhere, providing peace of mind for operators.

Overall, the Liebert 3000 combines high efficiency, advanced technology, and flexible design to deliver a robust power protection solution. Its reliability and performance make it a preferred choice for organizations seeking to protect their critical infrastructure while enhancing operational efficiency and sustainability. As businesses continue to rely on technology for their everyday operations, the Liebert 3000 stands out as a dependable safeguard against the uncertainties of power quality.