8 or 16 UTP Port LEDs

The LINK/ACTIVITY/PARTITION LEDs use two colors to display three states of operation for the 8 or 16 UTP ports. If a good link is established on any given port, the green LED will be continuously lit, indicating a valid network connection between the network node and the hub. When data is received, the LED will flash green. A flash may be longer or shorter depending on the length of the data packet being received. If the port is partitioned, it will display solid red.

If the LED does not display solid green indicating a good link, check the following:

1.Make sure the power is turned on for both the PC and EtheRx hub. The power LED should be lit.

2.Verify the network adapter has loaded its drivers from the PC. Some network adapters require the drivers to be loaded to establish a proper link.

3.Make sure the correct cable type is selected.

4.Make sure the cable is wired properly and connected on both ends.

5.If steps 1, 2, 3, and 4 are correct, the cable may be defective or not wired correctly. Replace the cable and try again. Please refer to Appendix A for pin assignments and Appendix B for cabling guidelines.

Cascade Switch

The Cascade Switch provides cable wiring flexibility on the last UTP Port (i.e., Port 8 or Port 16) for connecting to a workstation or cascading to another hub. By default, the last UTP port is set to “Crossover” (left side) as a standard, internally-crossed port, or MDI-X port. Depending on the wiring of your UTP cable (normally “Straight-Through”), the port is used to connect a workstation. For cascading to another hub using a straight-through cable, move the Cable Switch to “Straight-Through” (right side). If a crossover UTP cable is used to cascade to another hub, leave the Cable Switch in the “Crossover” position. See Figure 1-3 for a diagram showing the 16-Port KNE16TP/WG model. To verify the pin wiring of your UTP cable, refer to “Appendix B Cabling Guidelines” on page 17.

Kingston Technology Company

EtheRx User’s Guide - Rev. B00

Image 14
Contents Page Page Port and 16-Port Ethernet Hubs User’s Guide Part No -001.B00Page Table of Contents Kingston Technology Company EtheRx User’s Guide Rev. B00 Introduction KNE16TP/SEModel Types Port Hub ModelsSpecial Features Package ContentsJabber Lock-up Protection Design FeaturesRepeater Functions Fragment ExtensionAutomatic Partitioning/Reconnection Link TestFront Panel Hardware InstallationPower LED Stacking Ports SE models onlyUtilization and Collision LEDs AUI LEDCascade Switch Or 16 UTP Port LEDsUsing a Straight-Through Cable Using a Crossover Cable BNC Port Pin AC Power JackRear Panel AUI PortEthernet Star Network Network ConfigurationsEthernet 5-4-3 Rule Linear Bus Network Horizontal CascadingStacking EtheRx SE Hubs Stack up to Five SE HubsAppendices Appendix a Pin Assignments UTP Pin AssignmentsAUI Pin Assignments 16-Port models only Pin NumberCable Type UTP Cable WiringAppendix B Cabling Guidelines Cable Wiring Standards Fig. B-4 2-Pair UTP WiringAppendix C Specifications EtheRx 8-Port WorkGroup and Stackable HubsEtheRx 16-Port WorkGroup and Stackable Hubs Fig. D-1 Mounting Template specifications Appendix D Mounting TemplatesAppendix E Product Warranties and Notices Limited Warranty Duration of WarrantyWarranty Claim Requirements C. Certification CE NoticeHow to Reach Kingston Revision HistoryRevision Level Comment Same as above. For both 8-Port