AlphaServer 8400
Specifications
Physical Characteristics | Operating |
| Shipping | |
Height | 170.0 cm (67.0 in.) |
| 195.0 cm (76.7 in.) | |
Width | 80.0 cm (31.5 in.) |
| 109.5 cm (43.1 in.) | |
Depth | 87.5 cm (34.4 in.) |
| 121.0 cm (47.5 in.) | |
Weight, full configuration |
|
|
|
|
Without batteries | 408 kg (900 lb.) |
| 448 kg (1000 lb.) | |
With batteries | 545 kg (1200 lb.) |
| 585 kg (1300 lb.) | |
Clearances | Operating |
| Service | |
|
|
|
| |
Front | 1.0 m (40 in.) |
| 1.5 m (59 in.) | |
Rear | 1.0 m (40 in.) |
| 1.0 m (40 in.) | |
Sides | 0 |
| 0 |
|
Environmental | Operating |
|
| |
|
| |||
Temperature | 15° to 28°C (59° to 82°F) | 40° to 66°C ( 40° to 151°F) | ||
Humidity | 20% to 80% |
| 10% to 95% | |
Altitude | 0 2.4 km (08000 ft) | 9,100 m (30,000 ft) | ||
Vibration | 222 Hz @ 0.01"da minimum | 22500 Hz @ 0.25g max. | ||
Heat dissipation1 | Minimally configured system1 |
|
| |
| (system cabinet) |
|
|
|
| 3,400 Btu/hr, 1,000 W |
|
| |
| Fully configured system2 |
|
| |
| (system cabinet) |
|
|
|
| 15,700 Btu/hr, 4,600 W |
|
| |
| Fully configured system3 |
|
| |
| (system cabinet with two |
|
| |
| I/O expansion cabinets) |
|
| |
| 30,600 Btu/hr, 9,000 W |
|
| |
Regulatory |
|
|
|
|
|
|
|
| |
Agency approvals | UL Listed to UL1950 |
|
| |
| UL Classified to IEC950 |
|
| |
| CSA Certified to | |||
| FCC Part 15 (Class A) |
|
| |
| CE Declaration #1171 |
|
| |
Reviewed to | AS 3260, Australian Standard |
|
| |
| EN 60950, European Norm |
|
| |
Power Requirements1 |
|
|
|
|
US/Canada | Europe/AP |
| Japan | |
Nominal voltage | 120/208 V | 380415 V |
| 202 V |
Frequency range | 5060 Hz | 5060 Hz |
| 5060 Hz |
Phases |
| |||
| ||||
|
|
|
| |
Maximum input current/phase | 24 A rms | 12.8 A rms |
| 24 A rms |
Surge current | 50 A peak | 50 A peak |
| 50 A peak |
Rating | 30 A | 16 A |
| 30 A |
Power cap (system) | DEC | DEC | DEC | |
Receptacle (site) | DEC | See footnote 4 | DEC | |
(Industry equivalent) | NEMA | IEC 309 |
| NEMA |
PCS/PDS/PDU/UPS cable | BC24W | BN29X |
| BC24W |
1Minimally configured system contains one regulator, one CPU module, one memory module, one
2Fully configured system contains two power regulators, four CPU modules, three memory modules, two System I/O modules, one
3Fully configured system and expansion cabinets consist of the above “fully configured system” and two expansion cabinets which each contain one
4Receptacle type is Hubbell 516R6 or equivalent
Alpha Servers 3.229