ICP DAS USA user manual SST-2450 Settings

Page 17

5.2.SST-2450 Settings

When setting the SST-2450, you should first use a wire to connect the SET and GND pins. Quickly power off and power on the SST-2450, then launch the setting software program. There are only 3 steps required to make your settings.

1.Open a Serial Port.

2.Setting the operating mode.

3.Exit the program.

When setting the operating mode, please refer to the following steps:

When you set the SST-2450, you should never use the following settings:

SST-2450 (A)

SST-2450 (B)

Half-duplex

Half-duplex

Master

Slave

 

 

These settings will cause the SST-2450 set as the Master to be always on high power status and will cause the SST-2450 to fail. Please note that this situation isn’t covered by our warranty.

The correct settings are as follows:

SST-2450 (A)

SST-2450 (B)

Full-duplex

Full-duplex

 

 

Master

Slave

or

 

SST-2450 (A)

SST-2450 (B)

 

 

Half-duplex

Half-duplex

Slave

Slave

If you have a SST-2450 Network (i.e. more than 2 SST-2450 devices), you are only able to use the following specific setting for all of your SST-2450 devices:

Half-duplex

Slave

SST-2450 Wireless Modem User’s Manual Ver1.5, Feb /2003, OMH-030-10,---17

Image 17
Contents SST-2450 Wireless Modem User’s Manual Table of Contents Introduction PN code rate SpecificationsProduct Description SST-2450Block diagram Peer to Peer ApplicationsPC to PC connections --Using Mode Using Mode Both SST-2450 modules are setting as follows Both SST-2450 modules settings are as followsHalf-Duplex Connecting a PC to a PLC Using ModeUsing the 7188 as a Bridge -- Using Mode Application Network communicationApplication Quick Start instructions for the SST-2450 Installing the softwarePage SST-2450 Settings Page Testing the SST-2450 Testing error TroubleshootingSetting error Dimensions Din-rail Mounting External Antenna ANT-8Omni directional ANT-12PDirectional Appendix