Trouble Shooting

Problem

Cause

Solution

Generator is running

1. Generator circuit breaker

1. Reset circuit breaker.

but no AC output is

has tripped.

 

available.

 

 

 

2. Poor connection or

2. Check and repair.

 

defective cord set.

 

 

3. Connected device is bad.

3. Select a different load or

 

 

appliance that is in good

 

 

condition.

 

4. Fault in generator.

4. Contact a qualified

 

 

professional.

 

 

 

Generator runs good

1. Short circuit in a

1. Disconnect shorted electrical

but bogs down when

connected load.

load.

loads are connected.

 

 

 

2. Generator is overloaded.

2. Review load power

 

 

requirements and rearrange.

 

 

 

Switches are not

1. Switches are in OFF or LINE

1. Move switches to GEN

working with

position.

position.

generator power.

2. Generator circuit breaker

2. Reset circuit breaker.

 

 

has tripped.

 

 

3. Poor connection or

3. Check and repair.

 

defective cord set.

 

 

4. Connected device is bad.

4. Select a different load or

 

 

appliance that is in good

 

 

condition.

 

5. Fault in generator.

5. Contact a qualified

 

 

professional.

 

 

 

Appliances do not

1. Switches are in GEN or OFF

1. Move switches to LINE

operate after utility

position.

position.

power is restored.

 

 

 

2. Circuit breaker tripped.

2. Reset circuit breaker.

 

 

 

Only some loads

1. Circuit breaker tripped.

1. Reset circuit breaker.

work on generator

 

 

power.

2. Poor connection or

2. Check and repair.

 

 

defective cord set.

 

GFCI breaker on

1. Neutral / Ground bond in

1. Contact Honda dealer for

Honda generator

generator

alteration.

trips when

 

 

connected to switch

 

 

8