Hearth and Home Technologies WSK300 operating instructions Introduction, Installation

Page 1

WSK300

Multifunction Wall Control

Installation & Operating Instructions

WARNING

Hearth & Home Technologies disclaims any responsibility for, and the warranty will be voided by, the following actions:

Installation and use of any damaged system component.

Modification of the system component.

Installation other than as instructed by Hearth & Home Technologies.

Installation and/or use of any component part not approved by Hearth & Home Technologies.

Any such action may cause a fire hazard.

Read, understand and follow these instructions for safe installation and operation.

Introduction

The WSK300 multifunctional wall switch is designed to control flame height, blower speed, and up to 2 other 110- 120 VAC auxiliary functions on your gas fireplace. Also, the wall switch is equipped with thermostat functions which can automatically control the temperature in the room in which it is installed. The control is only for use with the Intellifire system (IPI). However, the pilot function can control the pilot flame as well. Electrical ratings for the control box are 110 VAC, 60 Hz, and is required for operation of this device.

Note: Whenever the fireplace is turned on, the flame size will always be on HI for 75 seconds, then the control will set the flame to the programmed setting.

Installation

1.Locate placement of wall control. The wall control must be located within 30 feet (within the line of sight) of the fireplace and 5 feet from the flooring. A maximum wire length of 50 feet may be used.

Note: The wall control is a three conductor, low voltage control that requires a minimum of a 22 gauge wire. The control is shipped with 18 feet of wire.

Placement of this wall switch may affect performance or accuracy of the automatic (thermostat) control. An as- sessment of the space should be done prior to installation for optimal performance. See the installation instructions section I for recommendations.

Note: The electrical junction box provided with the fireplace must be wired with 110 VAC before installing this kit. See owners manual for details.

All wiring should be done by a qualified electrician and shall be in compliance with local codes and with the National Electric Code ANSI/NFGA No. 70- current (in the United States), or with the current CSA C22.1 CANADIAN ELECTRIC CODE (in Canada).

WARNING

Shock Hazard

Do not provide any power to this unit until all wiring is completed. Failure to do so may destroy parts of this device and render it unusable, and may lead to possible electrical shock.

Fire Hazard

Modification of any parts or installation of dama- ged components will void the warranty, and you may possibly cause a fire hazard.

2.Remove wall control from packaging material.

3.Remove wall control back plate by pushing down on two tabs located at top left and right of control face.

4.Mount control box back on wall surface. Install two screws at holes provided on wall control back at top and bottom.

Note: This wall control is designed to mount to a wall junction box. To secure to wall properly ensure that a wall stud is located behind wall. For exterior wall installations, it is recommended that the junction box be sealed with caulking material. This will minimize heat loss through this location and improve the accuracy of the automatic (thermostat) operation.

5.Connect red, green and white wires from the fireplace control module to the terminal block located on the back of the control face panel.

Note: Ensure wires are connected to the correct color coded locations on terminal block face. Red to red, green to green, and white to white/yellow.

Printed in U.S.A. Copyright 2008

 

 

 

 

Hearth & Home Technologies Inc.

2101-915G 10/08

20802 Kensington Boulevard, Lakeville, MN 55044

 

 

 

1

Image 1
Contents Introduction InstallationInstalling the Hi/Lo Solenoid See Detail B-B Grnfor B-VENT Appliances Setting Flame Height / Manifold Pressure Installing the Control BoxButton & Display Key Wall ControlFunction Continuous Display Screen Function Temperature Scale Indicator Adjusting Flame Size Function on modeFunction Pilot settings Function Child Lockout feature Mode set to Function Timer settingsPress -/$%button until Thermostat setting is highlighted Function Room Temperature settingsFunction Auxiliary features Auxiliary FeaturesService Power Out OperationTroubleshooting Service Parts Troubleshooting