Hearth and Home Technologies installation instructions WSK-21 Wall Switch KIT

Page 1

Installation and Operation Instructions for the

WSK-21 WALL SWITCH KIT

Hearth Technologies Inc.

20802 Kensington Blvd.

Lakeville, MN 55044

CHECK CONTENTS OF SHIPPING CARTON

Compare contents of carton in Figure 1 with the actual parts received. If any parts are missing or damaged, contact your dealer before beginning installation. DO NOT install a damaged wall switch Kit.

INSTALLATION PRECAUTIONS

The WSK-21 Wall Switch Kit is tested and safe when installed in accordance with this installation manual. It is your responsibility to read all instructions before start- ing installation and to follow these instructions care- fully during installation.

The wall switch kit is carefully engineered and must be installed only as specified. If you modify it or any of its components, you will void the warranty and you may possibly cause a fire hazard.

CAUTION: All wiring should be done by a qualified electrician and shall be in compliance with local codes and with the National Electric Code ANSI/NFPA No. 70- current (in the United States), or with the current CSA C22.1 Canadian Electric Code (in Canada).

WARNING: DO NOT CONNECT 110-120 VAC WIR-

ING TO THE GAS CONTROL VALVE OF THIS APPLI- ANCE OR TO THE WALL SWITCH FOR INSTALLA- TION OF THIS KIT.

WARNING: FOR DSI UNITS - DO NOT USE THE WIRE SUPPLIED WITH THIS KIT. YOU MUST USE 12-14 AWG WIRE TYPE NM (ROMEX).

NOTE: Position the wall switch so that a maximum of 25 feet of wiring from the switch to the fireplace is used.

WALL

WALL

SWITCH

SWITCH

PLATE

 

SCREWS

 

WIRE

 

 

CONNECTORS (2)

FIGURE 1

1.0INSTALLATION INSTRUCTIONS FOR ALL MODELS EXCEPT GAS LOG SETS

1.1INSTALLING THE WALL SWITCH

1.Install the wall switch in a convenient location. Run low voltage, 2-conductor wire from the wall switch into the base of the unit.

NOTE: For model ST-38GTV run the wall switch wires through the pre-punched hole in the end of the fireplace.

2.Find the red and brown pigtail wires (labeled "FOR

USE WITH REMOTE OR WALL SWITCH ONLY") which are attached to fireplace's ON/OFF rocker switch located at the lower front corner of the unit. Connect these pigtail wires to the low voltage wires

1

130-900J 10/99

Image 1
Contents Check Contents of Shipping Carton WSK-21 Wall Switch KITInstallation Precautions Installing the Wall SwitchReplacement Parts and Customer Service Recommended Operating Procedures