Home Automation 37A00-1, 40A00-1 manual HAI Auxiliary Switch Overview, Changing Switch Color

Page 2

HAI Auxiliary Switch Overview

The 37A00-1 HAI Auxiliary Switch (Figure 2) is an optional companion device used with the HAI UPB™ Wall Switch for multi-way circuits. The HAI Auxiliary Switch has a Decora-style rocker switch that controls the load in the exact same manner as the Decora- style rocker switch on the HAI UPB™ Wall Switch.

LED

INDICATOR

TOP

BLACK

 

 

LINE

(ON)

GRAY

 

 

*NEUTRAL

 

 

 

 

BLUE

 

 

(FOR RED INDICATOR)

 

 

 

*NEUTRAL

 

 

 

 

(FOR BLUE INDICATOR)

YELLOW

BOTTOMCONTROL (OFF)

Figure 2 – HAI Auxiliary Switch

Changing Switch Color

The color of the HAI UPB™ Wall Switch and Auxiliary Switch may be changed to complement the interior décor. The HAI UPB™ Wall Switch and Auxiliary Switch is supplied with a white switch plate. Additional colors are available; contact your HAI distributor for more information. When changing the switch plate, make sure that the switch is disconnected from all power, and proceed as follows:

1. The switch plate attaches to the HAI UPB™ Wall Switch and Auxiliary Switch with two latches on the right and two on the left. Using a small-bladed screwdriver, gently depress the upper and lower latch on one side while lifting up on the plate. Once the latches are released on one side, remove the switch plate from the other side.

2.Align the latches of the new switch plate to the openings on the mounting plate

and gently snap into place.

Figure 3 – Changing Switch Color

INSTALLATION INSTRUCTIONS

The HAI UPB™ Wall Switch is wired directly to the load and can be controlled by adding one or more optional HAI Auxiliary Switches producing multi-way circuits. Multi-way circuits make it possible for a group of switches to control the same load. This section will illustrate how to make the connections.

Notes:

1.Refer to Figures 1 and Figure 2 to determine the wire colors for each connection.

2.All HAI UPB™ Wall Switches require a neutral (white) connection.

3.The Line (black) wire must be accessible for the installation of all HAI Auxiliary Switches. This wire may be connected to either phase of the 120/240V supply. The blue and/or gray wire on the HAI Auxiliary Switch can be connected to either earth ground or neutral. The blue and/or gray wire is only used to light the LED on the switch. This LED only indicates that power is applied and serves as a night-light. Connect the blue wire only to light the LED blue. Connect the gray wire only to light the LED red. Connect both the blue wire and the gray wire to light the LED magenta.

Image 2
Contents HAI UPB Wall Switch Overview Read These Instructions Before Installing DeviceImportant Notes Prior To Installation For the following ModelsInstallation Instructions HAI Auxiliary Switch OverviewChanging Switch Color Installation Procedure LoadHAI 15A Relay Switch Operation HAI Auxiliary Switch OperationSpecifications Model Number 40A00-1