Thermal Relay Overload
Amp Adjustment Dial: Turn this dial to meet your motor manufacturer's thermal overload amp setting specification. Typically this setting is
Trip Indicator: If the window is flagged yellow, the thermal relay has tripped.
Manual Contactor Override Lug: When pushed, the contactor is manually closed for troubleshooting purposes only.
ON Button:
When pushed, power is sent to the magnetic field coil and the contactor closes and sends power to the motor.
Manual/Auto Reset Lever:
In the up position, the thermal relay is in manual reset mode, where if tripped, you must first push the
red and then the green ON button reset button on the outside of the main cover to reset the thermal relay. In the down position, the thermal relay will automatically reset when it
Manual Trip Test Lever: If the thermal relay function
is in question, use a wooden toothpick to slide the yellow test lever to the left. If the motor
shuts off, the thermal relay has tripped and is functional.
OFF Button:
When pushed, the current going to the magnetic field coil is cut, which opens the contactor and cuts power to the motor.
Parts Breakdown
has cooled.
Reset Button:
When pushed, the thermal relay is reset and the yellow flag shown in the trip indicator window is cleared.
10
11
1
9
3 48
5 | 7 |
| 6 |
22-1
REF | PART # | DESCRIPTION |
|
|
|
1 | P4571001 | SWITCH BOX |
2 | P4571002 | SWITCH BOX COVER ASSEMBLY |
DATA LABEL, | ||
3 | P8293003 | CONTACTOR TECO |
4 | P4571004 | FIELD SWITCH TECO |
5 | P8293005 | RELAY TECO |
REF | PART # | DESCRIPTION |
|
|
|
6 | P4571006 | CONTACTOR RETAINER |
7 | PS55M | PHLP HD SCR |
8 | P4571008 | CAPTURED GROUND SCR |
9 | PS10 | PHLP HD SCR |
10 | P4571010 | |
11 | P4571011 | RUBBER SEAL |
COPYRIGHT © JANUARY, 2008 BY GRIZZLY INDUSTRIAL, INC. WARNING: NO PORTION OF THIS MANUAL MAY BE
REPRODUCED IN ANY SHAPE OR FORM WITHOUT THE WRITTEN APPROVAL OF GRIZZLY INDUSTRIAL, INC.
#CR10364 PRINTED IN TAIWAN