Thermal Relay Overload Amp | When pushed, the contactor | ON | Button: | When | pushed, | ||
Adjustment Dial: Turn this dial | is manually closed for trouble- | power is sent to the | magnetic | ||||
to the amperage setting speci- | shooting purposes only. | field | coil, closing the | contactor | |||
fied by the motor manufacturer. |
|
|
| and sending power to the motor. | |||
Typically, this setting is 100– |
|
|
|
|
|
|
|
110% of the amperage load listed |
|
|
|
|
|
|
|
on the motor data plate. Please |
|
|
| Manual/Auto Reset Lever: In | |||
note that turning this dial has |
|
|
| the up position, the thermal relay | |||
no effect on increasing motor |
|
|
| is in manual reset mode. This | |||
horsepower. If turned too high, |
|
|
| means you must | |||
the motor can overheat and be |
|
|
| outside cover and push the red | |||
damaged before the relay trips. |
|
|
| OFF button, then push the green | |||
|
|
|
| ON button to reset the thermal | |||
Trip Indicator: If this window |
|
|
| relay. In the down position, the | |||
|
|
| thermal relay | will automatically | |||
turns yellow, the thermal relay |
|
|
| reset when it has cooled. | |||
has tripped. |
|
|
|
|
|
|
|
Manual Trip Test Lever: If the |
|
|
| Reset Button: When | pushed, | ||
thermal relay function is in ques- |
|
|
| the thermal relay is reset, clear- | |||
tion, run the motor and use a |
|
|
| ing the yellow trip indicator win- | |||
wooden toothpick to slide the |
|
|
| dow. |
|
|
|
yellow test lever to the left. If the |
|
|
|
|
|
|
|
motor shuts off, the thermal relay |
|
|
|
|
|
|
|
has tripped and is functional. | OFF Button: When pushed, the current going to the magnetic field | ||||||
| coil is cut, which opens the contactor and cuts power to the motor. |
Parts Breakdown
10
11
1
9
3V2
4
8
6 7
5 | 2 |
|
|
REF | PART # | DESCRIPTION |
|
|
|
1 | P4571001 | SWITCH BOX |
2 | P4571002 | SWITCH BOX COVER ASSEMBLY |
DATA LABEL | ||
3V2 | P4571003V2 | CONTACTOR TECO |
4 | P4571004 | FIELD SWITCH TECO |
5 | P4573005 | OL RELAY TECO |
REF | PART # | DESCRIPTION |
|
|
|
6 | P4571006 | CONTACTOR RETAINER |
7 | PS55M | PHLP HD SCR |
8 | P4571008 | CAPTURED GROUND SCR |
9 | PS10 | PHLP HD SCR |
10 | P4571010 | |
11 | P4571011 | RUBBER SEAL |
Copyright © JANUARY, 2008 By Grizzly Industrial, Inc., REVISED JUNE, 2010 (TS)
Warning: No portion of this manual may be reproduced in any shape
Or form without the written approval of Grizzly Industrial, inc.
#CR10355 printed in TAIWAN
G4573 Magnetic Switch |