Set-up Procedure
1)First, make the appropriate settings for the PC.
2)Select VESA DPMS icon in the ScreenManager’s PowerManager menu.
3)Select “On”.
Power saving method of VESA DPMS and the monitor
E
VESA DPMS utilizes four signals: ON,
Signal | Screen | LED | Power consumption |
ON | Operation | Green | 110 W (normal) |
Blank | Green | 80% of normal | |
|
|
|
|
SUSPEND | Blank (Mode 1) | Flashing green | less than 10 W |
OFF | Blank (Mode 2) | Yellow | less than 3 W |
|
|
|
|
Off Timer
What is Off Timer?
The Off Timer function allows the user to set the time in which the monitor will be in operation, called the “On Period” and automatically shifts the operation into the “Off Timer Mode” when the set “On Period” expires. The energy consumption of the monitor in the “Off Timer Mode” is as low as the one of the monitor in “PowerManger Mode 2” although no setting PC to operate the Off Timer function is required.
(1)Select the “Off Timer” icon.
(2)Select “Enable”.
(3)Press the right/left key to adjust how long (1 to 23 hours) the monitor should be in the “On Period”.
Advance notice (LED flashing green) will be given 15 minutes before the monitor automatically enters the “Off Timer Mode”.
To Delay Entering the “Off Timer Mode”
To delay entering the “Off Timer Mode”, press any keys on the front panel located to the left of the power switch during the “Advance notice Mode”. The monitor will continue to operate for an additional 90 minutes. There will be another advance notice for 15 minutes as described. Delayed entrance into the “Off Timer Mode” can be extended as many times as desired.
2 SCREEN ADJUSTMENT 13