Eizo Dual Height Adjustable Stand Digital Mammography Monitor, Quality Control Sensor

Page 4

Displaying the Optimum Digital Mammography Image

EIZO offers all the necessary components for correct digital mammography image display.

Accessories

Dual Height Adjustable Stand

Digital Mammography Monitor

An option of clear base and blue base backlights are available.

Paired monitors which provides the same color and grayscale for two monitors bundled as a pair in one box, also available.

Standard Configuration

Quality Control Sensor

Once attached to the top of the monitor the Clip-On Swing Sensor G1 can remain in place and is ready for use. This saves the time and

trouble of attaching a n d r e m o v i n g i t whenperforming quality control tasks.

Quality Control Tool

EIZO's easy-to-use RadiCS quality control software performs precise calibration conforming to DICOM Part 14 and enables quality control complying with ACR Practice Guideline and other QC standard for digital mammography monitors.

Mount two panels in either portrait or landscape orientation.

Panel Protector

Protect against scratches and dust with high light transmission panel.

Monitor Cleaning Kit

Keep your screen free from dust and fingerprints with this screen cleaner kit. Includes pump spray and cloth. (Bundled with GS520-CLG and GS520-BLG.)

Quality Control of Digital Mammography Monitor

As with the use of film mammography, image quality testing of the monitor at installation and regularly during use should be carried out. This ensures that the monitor maintains a consistent display of quality digital mammography.

ACR “Practice Guideline for Determinants of Image

Quality in Digital Mammography”

A guideline established by the American College of Radiology (ACR) in cooperation with the American Association of Physicists in Medicine (AAPM), Radiological Society of North America (RSNA), and Society for Imaging Informatics in Medicine (SIIM).

High-Performance Graphics Board

Four options are available:

Bit

12-bit /10-bit / 8-bit

10-bit / 8-bit

8-bit

8-bit

Compatible Operating System

Windows XP / 2000 Professional

Windows XP / 2000 Professional

Windows XP

Windows XP

Frame Buffer Memory

128 MB

256 MB

1 GB

256 MB

Bus Interface

PCI 32-bit (33 MHz / 66 MHz)

PCI 32-bit (33 MHz) / 64-bit (66 MHz)

PCI Express x 16

PCI Express x 16 / x 1

Maximum Disply Resolutions

2048 x 2560

2048 x 2560

2048 x 2560

2048 x 2560

Output Terminals

DVI-I x 2

DVI-I x 2

DVI-D x 2

DVI-D x 2

Dot Clock

Up to 148 MHz

Up to 148 MHz

214.25 MHz

162 MHz

Scanning Frequency (H, V)

103.9 kHz

103.9 kHz

131 kHz

75 kHz

 

50 Hz

50 Hz

50 Hz

60 Hz

Maximum Power Consumption

16.8 watts

40 watts

75 watts

22 watts

 

 

 

 

 

5

EUREF “European Guidelines for Quality Assurance

in Breast Cancer Screening and Diagnosis”

A standard issued by the European Commission in cooperation with the European Reference Organization for Quality Assured Breast Screening and Diagnostic Services (EUREF), and European Breast Cancer Network (EBCN), European Society of Mastology (EUSOMA).

PAS 1054

Requirements and Testing of Digital Mammography Equipment ” established by the Normenausschusses Radiologie (DIN NAR) in cooperation with the Deutschen Röntgengesellschaft (DRG) and others. In line with the QS-RL (Qualitätssicherungs-Richtlinie) quality assurance ordinance, it is mandatory in Germany to refer to this standard when conducting monitor quality assurance.

6

Image 4
Contents Page Selecting the Optimum Digital Mammography Monitor Calibration Mode Selection Sharper Resolution for Clearer Image OutlineFull 5-Year Warranty Brightness Stability Within Usage Time GuaranteedDual Height Adjustable Stand Digital Mammography Monitor Monitor Cleaning KitQuality Control Sensor Quality Control ToolEizo Nanao Corporation supports Pink Ribbon activities