Enterasys Networks VHSIM2-A6DP manual PVC Vport Modifiable, Number of Virtual Queues Modifiable

Page 49

Traffic Management PVC Priority Assignments

PVC Vport (Modifiable)

Automatically displays the next available PVC Vport (Virtual Port) for configuration. This field displays the first unconfigured Virtual Port on the device as the default. The first unconfigured Virtual Port is always displayed as “NEW VPORT:n”, where n is the next available Virtual Port. There is only one Virtual Port accessible at any one time. Once this Virtual Port is configured, the next unconfigured Virtual Port is displayed. Using the SPACE bar or BACKSPACE keys will show currently configured Virtual Ports.

Number of Virtual Queues (Modifiable)

Up to 8 virtual queues per Virtual Port (virtual queue 0 - 7) can be listed. The default number of virtual queues per Virtual Port is 1. The number of queues may be changed by using the SPACE bar, BACKSPACE key, or typing the number of queues desired. If a value entered is larger than the number of queues supported on the platform, then a message stating the total number of queues supported is displayed across the top of the screen, and the previously displayed queue count is re-displayed. As the number of virtual queues is increased or decreased, it will cause the display in the table below to change accordingly. The field is one based for the users’ ease of reference, but the number of queues displayed in the table are zero based. For example, if the user is on a new Virtual Port and enters 3 into the number of virtual queue field, virtual queues 0-2 will appear in the table.

AAL Type (Read-Only)

Displays the ATM Adaptation Layer (AAL) being used by the PVC. The VHSIM2-A6DP only supports AAL Type 5 (AAL 5).

Encapsulation Type (Toggle)

Displays the type of data encapsulation that the VHSIM2-A6DP can use to perform LAN to ATM translation. This field toggles between the following options:

VC Mux 802.3 Bdg - VC Based Multiplexing for Bridged Protocols as defined by the IETF RFC 1483.

LLC Encapsulated - Logical Link Control for Bridged Protocols as defined by the IETF RFC 1483.

Encapsulation is set per Virtual Port on this screen. All PVCs on a particular Virtual Port must have the same type of encapsulation.

Virtual Queue (Read-Only)

Displays the virtual queues for logical ports. It is zero based like the Ethernet 802.1p Configuration screens. For example, if 8 is selected in the number of virtual queues fields, then virtual queues 0 - 7 will be displayed. The default value is 1, to display 1 virtual queue.

Local Management 3-15

Image 49
Contents VHSIM2-A6DP User’s Guide Page Page FCC Notice Enterasys NETWORKS, INC Program License Agreement Page Page Declaration of Conformity Contents Viii Contents Lanview Leds Figures VAPIM-31 VAPIM-39 VAPIM-39LR Tables Structure of this Guide WHO should USE this GuideATM Technology Guide Cabling Guide Related ManualsDocument Conventions Xvi Overview IntroductionATM Port Interface Modules APIMs and VAPIMs Lanview Diagnostic LEDsMIB Support Your email address Getting HelpPage Unpacking the VHSIM2-A6DP InstallationInstalling APIMs Removing the Apim Coverplate Installing an Apim Apim Screws Optional Third Installing VAPIMs 6Installation Installing a Vapim Vapim Screws Optional Third Installing a VHSIM2-A6DP in an Interface Module Installing a VhsimRemoving the Vhsim Coverplate Place the Vhsim behind the module faceplate. See Figure Installing a VHSIM2-A6DP in a Standalone Device 12Installation Local Management Local Management Screen Elements Using Local Management ScreensDisplay Field Event Message FieldDisplay Fields Command FieldsInput Fields Selection/Toggle FieldsLocal Management Keyboard Conventions Selecting Local Management Menu Screen Items Navigating Local Management ScreensUsing the Return Command Using the Exit CommandExiting Local Management Screens Connections Accessing the VHSIM2-A6DP ATM ScreenPhysical Port Configuration Connection Table ATM Connections ScreenConnections by Virtual Interface ATM Connection Setup ScreenATM Port Current Connections Read-Only Total Bandwidth Available Read-OnlyEncapsulation Type Read-Only Previous Command ADD/DELETE CommandATM Address ESI Read-Only Traffic Category Read-OnlyTraffic Management PVC Priority Assignments Screen Traffic Management PVC Priority AssignmentsNumber of Virtual Queues Modifiable PVC Vport ModifiableAAL Type Read-Only Encapsulation Type ToggleProfile Name Read-Only Profile Index ModifiableAdding Traffic Management PVC Priority Assignments 18Local Management Deleting an Entry Vport Modifying an Entry VportExample Traffic Management PVC Priority Assignments Screen Traffic Management PVC Priority Assignments Screen ExampleAdd/Delete Entry Screen ADD/DELETE Entry ScreenAdding an Entry PVC ADD/MODIFY CommandTraffic Profile Index Selectable Deleting an Entry PVC Modifying an Entry PVCTotal Bandwidth Allocated Read-Only ATM Connection Setup by Virtual Interface ScreenApplication Port # Read-only Virtual Interface # SelectableSelecting a Virtual Interface Prev CommandPort Framer Configuration Physical Port Configuration Menu ScreenPhysical Port Toggle Port Framer Configuration ScreenStatistics Toggle ATM Port Type Read-OnlyIdle Cells Toggle Cell Payload Scrambling ToggleATM Port Redundancy Configuration Screen Configuring an ApimRedundancy Status Toggle 12 ATM Port Redundancy Configuration ScreenActive Port Modifiable Primary Port ModifiableActivation of redundant port Toggle Revert to Primary port ToggleSetting the Primary Port Setting the Redundancy StatusTest Ports NOW Command Reset to Factory Defaults CommandSetting the Activation of Redundant Port Field Setting the Active PortSetting the Revert to Primary Port Field Setting the Periodic Test Time Setting the Periodic Test Status FieldUsing the Reset to Factory Defaults Command Using the Test Ports NOW CommandLAN Emulation Clients Screen LEC Table LEC Transmit Queues LEC Table ScreenVer Read-Only LEC ID Read-OnlyElan ID Read-Only Elan Name Read-Only15 LEC Administration Screen LEC Administration ScreenMTU Size Toggle Configure LEC ToggleSelective Multicast Toggle LLC Multiplex Capable ToggleLEC Index Read-Only/Modifiable LES ATM Address ModifiableLEC Status Toggle Lane Version ToggleModify Mode Command ADD LEC CommandCreate Mode Command Lecs ATM Address ModifiableChanging the LEC Status of an Existing LEC Configuring a New LEC AutomaticallyConfiguring a New LEC Manually 46Local Management Modifying an Existing LEC LEC Properties Screen Deleting an Existing LECActual Elan Name Read-Only LEC Index SelectableLEC ATM Addr Read-Only Lane Version Read-OnlyLecs ATM Addr Read-Only LES ATM Addr Read-OnlyViewing Multiple ELANs 17 LEC ARP Cache Screen LEC ARP Cache ScreenMAC Address Read-Only Search By Selectable# Selectable ATM Address Read-OnlyPerforming a Search Search CommandLEC Priority Queues Screen 18 Traffic Managment LEC Priority Queues Screen Number of Virtual Queues SelectableProfile Index Selectable Assigning Priorities to a LECIlmi Status Selectable Signalling ScreenIlmi State Read-Only Restart Ilmi Command Restart UNI CommandIlmi Physical ATM Address Read-Only UNI Status ToggleChanging the UNI Version Changing the Ilmi Status to DisabledRestarting UNI Changing the UNI StatusRestarting the Ilmi Profile Name Selectable Traffic Management ScreenTraffic Parameters Transmit Units Selectable Traffic Category SelectableTraffic Parameters Peak Cell Rate PCR Selectable Sustained Cell Rate SCR SelectableModifying a Descriptor Profile Setting up a Descriptor ProfileDeleting a Descriptor Profile Discovery Elan Setup Screen Status Toggle Mode ToggleAssigning the VHSIM2-A6DP to a Discovery Elan VHSIM2-A6DP LEDs Lanview LEDsFlashing Environment SpecificationsRegulatory Compliance Page APIM-21 Specifications Apim and Vapim SpecificationsFigure B-2 APIM-29 APIM-29 SpecificationsFigure B-3 APIM-29LR APIM-29LR SpecificationsSTS3 APIM-22 SpecificationsBNC APIM-67 Specifications6APIM and Vapim Specifications Figure B-7 VAPIM-31 VAPIM-31 SpecificationsFigure B-8 VAPIM-39 VAPIM-39 SpecificationsFigure B-9 VAPIM-39LR VAPIM-39LR SpecificationsPage Index Index-2 Index-3

VHSIM2-A6DP specifications

Enterasys Networks VHSIM2-A6DP is a versatile component designed to enhance the efficiency and functionality of network infrastructure. This module is part of the Enterasys family of products, known for their reliability and advanced networking capabilities. The VHSIM2-A6DP is specifically engineered to support a range of applications, particularly in enterprise environments.

One of the most notable features of the VHSIM2-A6DP is its ability to provide high-density connectivity. This module supports multiple ports, allowing businesses to connect numerous devices seamlessly. This high-capacity connectivity is crucial for organizations looking to expand their network without significant overhauls, thus reducing operational costs.

In terms of technologies, the VHSIM2-A6DP is built on the foundation of robust Ethernet standards, which ensures compatibility with a wide variety of devices and systems. It supports both Power over Ethernet (PoE) capabilities and standard Ethernet connections, which enables the simultaneous delivery of power and data to connected devices. This is particularly useful for powering devices like IP cameras, VoIP phones, and wireless access points without needing separate power sources.

The VHSIM2-A6DP also incorporates support for advanced security features. With the growing importance of cybersecurity, this module includes capabilities to enhance network protection, safeguarding sensitive data and maintaining compliance with industry standards. This includes features like secure authentication, encryption protocols, and traffic segmentation, which together contribute to a more secure network environment.

Additionally, the module is designed with ease of management in mind. It comes equipped with user-friendly interfaces and is compatible with Enterasys' management software tools, allowing for streamlined network administration. Administrators can easily monitor performance metrics, configure settings, and deploy firmware updates, all contributing to reduced downtime and improved network performance.

Scalability is another key characteristic of the VHSIM2-A6DP. Organizations can start with a basic configuration and expand as needed without significant changes to the existing infrastructure. This adaptability makes it an ideal choice for companies looking to grow while maintaining cost efficiency.

Overall, the Enterasys Networks VHSIM2-A6DP stands out in its category thanks to its high-density connectivity, support for advanced technologies, robust security features, ease of management, and scalability. These characteristics make it a valuable asset in the toolkit of any IT department aiming to build a flexible and secure networking environment.