Enterasys Networks VHSIM2-A6DP manual Installing VAPIMs

Page 27

Installing VAPIMs

5.Press down firmly on the APIM until the pins slide all the way into the connector. Ensure the APIM sits flush on the standoffs. If the APIM does not sit flush with the standoffs, ensure that the pins have been inserted into the correct connector on the VHSIM2-A6DP. Refer to Figure 2-2.

6.Secure the APIM with the screws saved in step 3. The screw used to attach the rear of the APIM to the standoff is optional, and is not necessary for proper installation. Refer to Figure 2-2.

7.Reattach the faceplate to the VHSIM2-A6DP using the three screws saved in step 2.

2.3INSTALLING VAPIMs

ELECTRICAL HAZARD: Only qualified personnel should install or service this unit.

To install a VAPIM into the VHSIM2-A6DP, proceed as follows:

1.Attach the antistatic wrist strap (refer to the instructions on the antistatic wrist strap package).

2.Remove and save the faceplate screws attaching the faceplate to the VHSIM2-A6DP. See Figure 2-3. Remove the VHSIM2-A6DP faceplate.

3.Remove and save the three screws from the VHSIM2-A6DP standoffs. Remove the APIM coverplate.

Installation 2-5

Image 27
Contents VHSIM2-A6DP User’s Guide Page Page FCC Notice Enterasys NETWORKS, INC Program License Agreement Page Page Declaration of Conformity Contents Viii Contents Lanview Leds Figures VAPIM-31 VAPIM-39 VAPIM-39LR Tables Structure of this Guide WHO should USE this GuideATM Technology Guide Cabling Guide Related ManualsDocument Conventions Xvi Overview IntroductionLanview Diagnostic LEDs ATM Port Interface Modules APIMs and VAPIMsMIB Support Your email address Getting HelpPage Unpacking the VHSIM2-A6DP InstallationInstalling APIMs Removing the Apim Coverplate Installing an Apim Apim Screws Optional Third Installing VAPIMs 6Installation Installing a Vapim Vapim Screws Optional Third Installing a VHSIM2-A6DP in an Interface Module Installing a VhsimRemoving the Vhsim Coverplate Place the Vhsim behind the module faceplate. See Figure Installing a VHSIM2-A6DP in a Standalone Device 12Installation Local Management Local Management Screen Elements Using Local Management ScreensDisplay Field Event Message FieldSelection/Toggle Fields Command FieldsDisplay Fields Input FieldsLocal Management Keyboard Conventions Selecting Local Management Menu Screen Items Navigating Local Management ScreensUsing the Exit Command Using the Return CommandExiting Local Management Screens Connections Accessing the VHSIM2-A6DP ATM ScreenPhysical Port Configuration Connection Table ATM Connections ScreenConnections by Virtual Interface ATM Connection Setup ScreenTotal Bandwidth Available Read-Only ATM Port Current Connections Read-OnlyEncapsulation Type Read-Only Traffic Category Read-Only ADD/DELETE CommandPrevious Command ATM Address ESI Read-OnlyTraffic Management PVC Priority Assignments Screen Traffic Management PVC Priority AssignmentsEncapsulation Type Toggle PVC Vport ModifiableNumber of Virtual Queues Modifiable AAL Type Read-OnlyProfile Name Read-Only Profile Index ModifiableAdding Traffic Management PVC Priority Assignments 18Local Management Deleting an Entry Vport Modifying an Entry VportExample Traffic Management PVC Priority Assignments Screen Traffic Management PVC Priority Assignments Screen ExampleAdd/Delete Entry Screen ADD/DELETE Entry ScreenADD/MODIFY Command Adding an Entry PVCTraffic Profile Index Selectable Deleting an Entry PVC Modifying an Entry PVCTotal Bandwidth Allocated Read-Only ATM Connection Setup by Virtual Interface ScreenApplication Port # Read-only Virtual Interface # SelectableSelecting a Virtual Interface Prev CommandPort Framer Configuration Physical Port Configuration Menu ScreenPhysical Port Toggle Port Framer Configuration ScreenCell Payload Scrambling Toggle ATM Port Type Read-OnlyStatistics Toggle Idle Cells ToggleATM Port Redundancy Configuration Screen Configuring an ApimRedundancy Status Toggle 12 ATM Port Redundancy Configuration ScreenRevert to Primary port Toggle Primary Port ModifiableActive Port Modifiable Activation of redundant port ToggleReset to Factory Defaults Command Setting the Redundancy StatusSetting the Primary Port Test Ports NOW CommandSetting the Active Port Setting the Activation of Redundant Port FieldSetting the Revert to Primary Port Field Setting the Periodic Test Time Setting the Periodic Test Status FieldUsing the Test Ports NOW Command Using the Reset to Factory Defaults CommandLAN Emulation Clients Screen LEC Table LEC Transmit Queues LEC Table ScreenElan Name Read-Only LEC ID Read-OnlyVer Read-Only Elan ID Read-Only15 LEC Administration Screen LEC Administration ScreenLLC Multiplex Capable Toggle Configure LEC ToggleMTU Size Toggle Selective Multicast ToggleLane Version Toggle LES ATM Address ModifiableLEC Index Read-Only/Modifiable LEC Status ToggleLecs ATM Address Modifiable ADD LEC CommandModify Mode Command Create Mode CommandChanging the LEC Status of an Existing LEC Configuring a New LEC AutomaticallyConfiguring a New LEC Manually 46Local Management Modifying an Existing LEC LEC Properties Screen Deleting an Existing LECActual Elan Name Read-Only LEC Index SelectableLES ATM Addr Read-Only Lane Version Read-OnlyLEC ATM Addr Read-Only Lecs ATM Addr Read-OnlyViewing Multiple ELANs 17 LEC ARP Cache Screen LEC ARP Cache ScreenATM Address Read-Only Search By SelectableMAC Address Read-Only # SelectableSearch Command Performing a SearchLEC Priority Queues Screen 18 Traffic Managment LEC Priority Queues Screen Number of Virtual Queues SelectableProfile Index Selectable Assigning Priorities to a LECSignalling Screen Ilmi Status SelectableIlmi State Read-Only UNI Status Toggle Restart UNI CommandRestart Ilmi Command Ilmi Physical ATM Address Read-OnlyChanging the UNI Version Changing the Ilmi Status to DisabledChanging the UNI Status Restarting UNIRestarting the Ilmi Profile Name Selectable Traffic Management ScreenSustained Cell Rate SCR Selectable Traffic Category SelectableTraffic Parameters Transmit Units Selectable Traffic Parameters Peak Cell Rate PCR SelectableSetting up a Descriptor Profile Modifying a Descriptor ProfileDeleting a Descriptor Profile Discovery Elan Setup Screen Status Toggle Mode ToggleAssigning the VHSIM2-A6DP to a Discovery Elan VHSIM2-A6DP LEDs Lanview LEDsFlashing Specifications EnvironmentRegulatory Compliance Page APIM-21 Specifications Apim and Vapim SpecificationsFigure B-2 APIM-29 APIM-29 SpecificationsFigure B-3 APIM-29LR APIM-29LR SpecificationsSTS3 APIM-22 SpecificationsBNC APIM-67 Specifications6APIM and Vapim Specifications Figure B-7 VAPIM-31 VAPIM-31 SpecificationsFigure B-8 VAPIM-39 VAPIM-39 SpecificationsFigure B-9 VAPIM-39LR VAPIM-39LR SpecificationsPage Index Index-2 Index-3

VHSIM2-A6DP specifications

Enterasys Networks VHSIM2-A6DP is a versatile component designed to enhance the efficiency and functionality of network infrastructure. This module is part of the Enterasys family of products, known for their reliability and advanced networking capabilities. The VHSIM2-A6DP is specifically engineered to support a range of applications, particularly in enterprise environments.

One of the most notable features of the VHSIM2-A6DP is its ability to provide high-density connectivity. This module supports multiple ports, allowing businesses to connect numerous devices seamlessly. This high-capacity connectivity is crucial for organizations looking to expand their network without significant overhauls, thus reducing operational costs.

In terms of technologies, the VHSIM2-A6DP is built on the foundation of robust Ethernet standards, which ensures compatibility with a wide variety of devices and systems. It supports both Power over Ethernet (PoE) capabilities and standard Ethernet connections, which enables the simultaneous delivery of power and data to connected devices. This is particularly useful for powering devices like IP cameras, VoIP phones, and wireless access points without needing separate power sources.

The VHSIM2-A6DP also incorporates support for advanced security features. With the growing importance of cybersecurity, this module includes capabilities to enhance network protection, safeguarding sensitive data and maintaining compliance with industry standards. This includes features like secure authentication, encryption protocols, and traffic segmentation, which together contribute to a more secure network environment.

Additionally, the module is designed with ease of management in mind. It comes equipped with user-friendly interfaces and is compatible with Enterasys' management software tools, allowing for streamlined network administration. Administrators can easily monitor performance metrics, configure settings, and deploy firmware updates, all contributing to reduced downtime and improved network performance.

Scalability is another key characteristic of the VHSIM2-A6DP. Organizations can start with a basic configuration and expand as needed without significant changes to the existing infrastructure. This adaptability makes it an ideal choice for companies looking to grow while maintaining cost efficiency.

Overall, the Enterasys Networks VHSIM2-A6DP stands out in its category thanks to its high-density connectivity, support for advanced technologies, robust security features, ease of management, and scalability. These characteristics make it a valuable asset in the toolkit of any IT department aiming to build a flexible and secure networking environment.