Enterasys Networks 4H4283-49 manual Installation Site Requirement, Unpacking the DFE-Gold Module

Page 32

Installation Site Requirement

Installation Site Requirement

The DFE‐Gold module must be installed in a Matrix E7, N1, N3, N5, or N7 chassis located in a Restricted Access Location (RAL). This location should only be accessible by people that have been trained or are technically competent enough to be aware of potential risks of accessing the hazardous areas of the chassis. Locations such as a locked wiring closet or locked cabinet meet this requirement.

Warning: Install this module in a Matrix E7, N1, N3, N5, or N7 chassis that has been installed in a Restricted Access Location only. Access to the equipment by users must be restricted through the use of a tool or lock and key or other means of security and is controlled by the authority responsible for the location.

Advertencia: Instalar este modulo en un Matrix E7, N1, N3, N5, o N7 que ha sido localizado en un lugar de Acceso Restringido. Aceso al equipo debe ser restringido por el responsable del sitio.

Warnhinweis: Installieren Sie dieses Modul nur in einem E7, N1, N3, N5, oder N7 Chassis, wenn sich diese in einer zugangsgeschützten Umgebung befinden. Der Bereich zu den Komponenten sollte durch ein Schloß, einen Schlüssel oder sonstigen Sicherungen geschützt und durch einen Verantwortlichen kontrolliert werden.

Unpacking the DFE-Gold Module

Unpack the DFE‐Gold module as follows:

1.Open the box and remove the packing material protecting the DFE‐Gold module.

2.Verify the contents of the carton as listed in Table 3‐1.

Table 3-1 Contents of DFE-Gold Module Carton

Item

Quantity

 

 

DFE-Gold module

1

 

 

Installation Guide

1

 

 

Customer Release Notes

1

 

 

3.Remove the tape seal on the non‐conductive bag to remove the DFE‐Gold module.

4.Perform a visual inspection of the DFE‐Gold module for any signs of physical damage. Contact Enterasys Networks if there are any signs of damage. Refer to “Getting Help” on page xviii for details.

3-2 Installation

Image 32
Contents Enterasys Matrix Page Page Regulatory Compliance Information Electromagnetic Compatibility EMC Supplement to Product Instructions Vcci Notice Safety Information Class 1 Laser Transceivers Enterasys NETWORKS, INC. Firmware License Agreement Viii Page Page Contents Index TroubleshootingAppendix a Specifications Figures Contents of DFE-Gold Module Carton TablesImportant Notice About This GuideWho Should Use This Guide For Refer to How to Use This GuideRelated Documents Conventions Used in This Guide Following conventions are used in this guideGetting Help Introduction Overview of DFE-Gold Series CapabilitiesDFE-Gold Modules 4H4282-494H4283-49 4H4203-724H4202-72 4H4284-49DFE 4H4202-72 and 4H4284-49 DFE-Gold Modules Connectivity Switch Configuration Using WebView Switch Configuration Using CLI CommandsManagement Standards CompatibilityLanview Diagnostic LEDs Network Requirements 10BASE-T Network100BASE-TX Network 100BASE-FX Fiber-Optic NetworkInstallation Unpacking the DFE-Gold Module Installation Site RequirementContents of DFE-Gold Module Carton Quantity Installing Optional Network Expansion Module DFE Module Placement and Installation RulesExample 1 -1, a Example 2 -1, BExample 4 -1, D Installing Module into a ChassisExample 3 -1, C Installing Module into Matrix E7 or N7 Chassis PreparationInstalling Module into a Chassis ➆ ➁ Installing Module into Matrix N1, N3, or N5 Chassis Connecting to the Network Connecting to the NetworkConnecting UTP Cables to 4H4282-49 or 4H4202-72 Connecting a Twisted Pair Segment With RJ45 Connector RX+ TX+ TX1+ RX1 TX2+ TX3+ RX3 RX2 TX4+ RX4 Connecting UTP Cables to 4H4283-49 or 4H4203-72 Connecting a Twisted Pair Using RJ21 Straight Connector 10 Connection Using Optional RJ21 Angle Adapter Connecting Fiber-Optic Cables to 4H4284-49 COM Mgmt CPU Connecting to COM Port for Local Management What Is NeededConnecting to an IBM PC or Compatible Device Parameter SettingConnecting to a VT Series Terminal 12 Connecting an IBM PC or CompatibleConnecting to a Modem 13 Connecting a VT Series Terminal14 Connecting to a Modem VT Series Port Adapter Wiring and Signal Diagram RJ45 DB25 Adapter Wiring and Signal AssignmentsCOM Port Adapter Wiring and Signal Diagram RJ45 Modem Port Adapter Wiring and Signal Diagram RJ45 DB25 Completing the InstallationCompleting the Installation of a New System First-Time Log-In Using a Console Port Connection 15 Matrix DFE Startup Screen Example N7 Chassis Logging in with an Administratively-Configured User Account EnterCompleting the Installation About the Management Mgmt LED TroubleshootingUsing Lanview Lanview LEDs on 4H4282-49, 4H4283-49, and 4H4203-72 Viewing Receive/Transmit Activity on 4H4202-72 Lanview LEDs on 4H4202-72Viewing the Receive and Transmit Activity on 4H4284-49 Lanview LEDs on 4H4284-49Lanview LEDs Color State Recommended ActionLED Troubleshooting Checklist Refer to the Enterasys Matrix DFE-Gold SeriesEnterasys Matrix DFE-Gold Series Configuration Overview of DFE-Gold Module Shutdown Procedure OFFLINE/RESET SwitchRecommended Shutdown Procedure Using OFFLINE/RESET Switch Last Resort Shutdown Procedure Using OFFLINE/RESET SwitchTable A-1 Specifications SpecificationsDFE-Gold Module Specifications Chassis Backplane Connectivity Table A-2 COM Port Pin Assignments Signal Name Input/Output COM Port Pinout AssignmentsRegulatory Compliance Table A-3 Compliance Standards Regulatory ComplianceMode Switch Bank Settings Optional Installations Required ToolsSetting the Mode Switches Figure B-1 Mode Switch Location on 4H4282-49 and 4H4283-49 Figure B-3 Mode Switch Location on 4H4202-72 Memory Locations and Replacement Procedures Location of Dimm and Dram Simm Memory ModulesFigure B-6 Dimm and Dram Simm Locations 4H4203-72 Dimm Replacement Procedure 4H4282-49 and 4H4283-49 Removing the Dram SimmInstalling the Dram Simm on 4H4282-49 or 4H4283-49 Removing the Dram Simm from 4H4203-72 Installing the Dram Simm on 4H4203-72 Figure B-11 Removing Existing Dram Simm from 4H4203-72Dram Simm Replacement 4H4202-72 Figure B-12 Installing the Dram Simm on 4H4203-72Dimm Replacement Procedure All DFE Modules Removing the DimmInstalling the Dimm Figure B-14 Installing the DimmPage Index NumericsOFFLINE/RESET button 4-10Optional network expansion module
Related manuals
Manual 90 pages 34.94 Kb

4H4203-72, 4H4283-49, 4H4282-49, 4H4202-72, 4H4284-49 specifications

Enterasys Networks has long been a leader in providing robust networking solutions for enterprises, and their range of products, including models 4H4284-49, 4H4202-72, 4H4282-49, 4H4283-49, and 4H4203-72, exemplifies their commitment to delivering high-performance networking equipment. These models are designed to meet the increasing demands of modern network environments, ensuring scalability, reliability, and security.

One of the standout features of the Enterasys Networks products is their advanced Layer 2 and Layer 3 switching capabilities. This allows for efficient data transmission and fundamental network routing processes, making them ideal for both small business networks and large enterprise setups. The models boast high throughput rates and low latency, which are essential for applications requiring real-time data transfer, such as video conferencing and VoIP.

Additionally, these switches are equipped with Power over Ethernet (PoE) functionality, enabling users to power devices like IP phones, wireless access points, and security cameras directly from the switch. This eliminates the need for additional electrical wiring, simplifying installation and reducing costs. The power budget is adequately managed, ensuring that all connected devices operate efficiently.

In terms of security, Enterasys Networks has integrated advanced features such as VLAN support and Access Control Lists (ACLs) to enhance network segmentation and safeguard against unauthorized access. This is particularly crucial in environments where sensitive data is handled. The inclusion of network monitoring and management tools further aids IT teams in maintaining optimal network performance and detecting potential issues proactively.

Moreover, these models support a variety of networking protocols, which adds flexibility and compatibility with existing infrastructure. The user-friendly web interface and CLI enable easy configuration and management, catering to network administrators' diverse levels of expertise.

Built with high-quality materials, Enterasys Networks devices are designed to withstand the rigors of a data center environment, ensuring longevity and reliable performance. The combination of these features makes the 4H4284-49, 4H4202-72, 4H4282-49, 4H4283-49, and 4H4203-72 models excellent choices for organizations looking to enhance their networking capabilities and ensure a secure, efficient communication network that can grow with their needs. Overall, Enterasys Networks continues to set benchmarks in networking technology, making significant strides in improving connectivity and performance for enterprises worldwide.