Enterasys Networks 4H4284-49, 4H4202-72, 4H4283-49, 4H4282-49 Electromagnetic Compatibility EMC

Page 5

Electromagnetic Compatibility (EMC)

This product complies with the following: 47 CFR Parts 2 and 15, CSA C108.8, 2004/108/EC, EN 55022, EN 61000‐3‐2, EN 61000‐3‐3, EN 55024, AS/NZS CISPR 22, VCCI V‐3.

Compatibilidad Electromágnetica (EMC)

Este producto de Enterasys cumple con lo siguiente: 47 CFR Partes 2 y 15, CSA C108.8, 2004/108/EC, EN 55022, EN 55024, EN 61000‐3‐2, EN 61000‐3‐3, AS/NZS CISPR 22, VCCI V‐3.

Elektro- magnetische Kompatibilität ( EMC )

Dieses Produkt entspricht den folgenden Richtlinien: 47 CFR Parts 2 and 15, CSA C108.8, 2004/108/EC, EN 55022, EN 61000‐3‐2, EN 61000‐3‐3, EN 55024, AS/NZS CISPR 22, VCCI V‐3.

Hazardous Substances

This product complies with the requirements of European Directive, 2002/95/EC, Restriction of Hazardous Substances (RoHS) in Electrical and Electronic Equipment.

European Waste Electrical and Electronic Equipment (WEEE) Notice

In accordance with Directive 2002/96/EC of the European Parliament on waste electrical and electronic equipment (WEEE):

1.The symbol above indicates that separate collection of electrical and electronic equipment is required and that this product was placed on the European market after August 13, 2005, the date of enforcement for Directive 2002/96/EC.

2.When this product has reached the end of its serviceable life, it cannot be disposed of as unsorted municipal waste. It must be collected and treated separately.

3.It has been determined by the European Parliament that there are potential negative effects on the environment and human health as a result of the presence of hazardous substances in electrical and electronic equipment.

4.It is the users’ responsibility to utilize the available collection system to ensure WEEE is properly treated. For information about the available collection system, please go to www.enterasys.com/support/ or contact

iii

Image 5
Contents Enterasys Matrix Page Page Regulatory Compliance Information Electromagnetic Compatibility EMC Supplement to Product Instructions Vcci Notice Safety Information Class 1 Laser Transceivers Enterasys NETWORKS, INC. Firmware License Agreement Viii Page Page Contents Index TroubleshootingAppendix a Specifications Figures Tables Contents of DFE-Gold Module CartonImportant Notice About This GuideWho Should Use This Guide For Refer to How to Use This GuideRelated Documents Following conventions are used in this guide Conventions Used in This GuideGetting Help Overview of DFE-Gold Series Capabilities Introduction4H4282-49 DFE-Gold Modules4H4283-49 4H4203-724H4284-49 4H4202-72DFE 4H4202-72 and 4H4284-49 DFE-Gold Modules Connectivity Switch Configuration Using CLI Commands Switch Configuration Using WebViewManagement Standards CompatibilityLanview Diagnostic LEDs 10BASE-T Network Network Requirements100BASE-FX Fiber-Optic Network 100BASE-TX NetworkInstallation Unpacking the DFE-Gold Module Installation Site RequirementContents of DFE-Gold Module Carton Quantity DFE Module Placement and Installation Rules Installing Optional Network Expansion ModuleExample 2 -1, B Example 1 -1, aExample 4 -1, D Installing Module into a ChassisExample 3 -1, C Preparation Installing Module into Matrix E7 or N7 ChassisInstalling Module into a Chassis ➆ ➁ Installing Module into Matrix N1, N3, or N5 Chassis Connecting to the Network Connecting to the NetworkConnecting UTP Cables to 4H4282-49 or 4H4202-72 Connecting a Twisted Pair Segment With RJ45 Connector RX+ TX+ TX1+ RX1 TX2+ TX3+ RX3 RX2 TX4+ RX4 Connecting UTP Cables to 4H4283-49 or 4H4203-72 Connecting a Twisted Pair Using RJ21 Straight Connector 10 Connection Using Optional RJ21 Angle Adapter Connecting Fiber-Optic Cables to 4H4284-49 COM Mgmt CPU What Is Needed Connecting to COM Port for Local ManagementParameter Setting Connecting to an IBM PC or Compatible Device12 Connecting an IBM PC or Compatible Connecting to a VT Series Terminal13 Connecting a VT Series Terminal Connecting to a Modem14 Connecting to a Modem VT Series Port Adapter Wiring and Signal Diagram RJ45 DB25 Adapter Wiring and Signal AssignmentsCOM Port Adapter Wiring and Signal Diagram RJ45 Modem Port Adapter Wiring and Signal Diagram RJ45 DB25 Completing the InstallationCompleting the Installation of a New System First-Time Log-In Using a Console Port Connection 15 Matrix DFE Startup Screen Example N7 Chassis Enter Logging in with an Administratively-Configured User AccountCompleting the Installation About the Management Mgmt LED TroubleshootingUsing Lanview Lanview LEDs on 4H4282-49, 4H4283-49, and 4H4203-72 Lanview LEDs on 4H4202-72 Viewing Receive/Transmit Activity on 4H4202-72Lanview LEDs on 4H4284-49 Viewing the Receive and Transmit Activity on 4H4284-49Color State Recommended Action Lanview LEDsLED Refer to the Enterasys Matrix DFE-Gold Series Troubleshooting ChecklistEnterasys Matrix DFE-Gold Series Configuration OFFLINE/RESET Switch Overview of DFE-Gold Module Shutdown ProcedureLast Resort Shutdown Procedure Using OFFLINE/RESET Switch Recommended Shutdown Procedure Using OFFLINE/RESET SwitchTable A-1 Specifications SpecificationsDFE-Gold Module Specifications Chassis Backplane Connectivity COM Port Pinout Assignments Table A-2 COM Port Pin Assignments Signal Name Input/OutputTable A-3 Compliance Standards Regulatory Compliance Regulatory ComplianceRequired Tools Mode Switch Bank Settings Optional InstallationsSetting the Mode Switches Figure B-1 Mode Switch Location on 4H4282-49 and 4H4283-49 Figure B-3 Mode Switch Location on 4H4202-72 Location of Dimm and Dram Simm Memory Modules Memory Locations and Replacement ProceduresFigure B-6 Dimm and Dram Simm Locations 4H4203-72 Removing the Dram Simm Dimm Replacement Procedure 4H4282-49 and 4H4283-49Installing the Dram Simm on 4H4282-49 or 4H4283-49 Removing the Dram Simm from 4H4203-72 Figure B-11 Removing Existing Dram Simm from 4H4203-72 Installing the Dram Simm on 4H4203-72Figure B-12 Installing the Dram Simm on 4H4203-72 Dram Simm Replacement 4H4202-72Removing the Dimm Dimm Replacement Procedure All DFE ModulesFigure B-14 Installing the Dimm Installing the DimmPage Numerics IndexOFFLINE/RESET button 4-10Optional network expansion module
Related manuals
Manual 90 pages 34.94 Kb

4H4203-72, 4H4283-49, 4H4282-49, 4H4202-72, 4H4284-49 specifications

Enterasys Networks has long been a leader in providing robust networking solutions for enterprises, and their range of products, including models 4H4284-49, 4H4202-72, 4H4282-49, 4H4283-49, and 4H4203-72, exemplifies their commitment to delivering high-performance networking equipment. These models are designed to meet the increasing demands of modern network environments, ensuring scalability, reliability, and security.

One of the standout features of the Enterasys Networks products is their advanced Layer 2 and Layer 3 switching capabilities. This allows for efficient data transmission and fundamental network routing processes, making them ideal for both small business networks and large enterprise setups. The models boast high throughput rates and low latency, which are essential for applications requiring real-time data transfer, such as video conferencing and VoIP.

Additionally, these switches are equipped with Power over Ethernet (PoE) functionality, enabling users to power devices like IP phones, wireless access points, and security cameras directly from the switch. This eliminates the need for additional electrical wiring, simplifying installation and reducing costs. The power budget is adequately managed, ensuring that all connected devices operate efficiently.

In terms of security, Enterasys Networks has integrated advanced features such as VLAN support and Access Control Lists (ACLs) to enhance network segmentation and safeguard against unauthorized access. This is particularly crucial in environments where sensitive data is handled. The inclusion of network monitoring and management tools further aids IT teams in maintaining optimal network performance and detecting potential issues proactively.

Moreover, these models support a variety of networking protocols, which adds flexibility and compatibility with existing infrastructure. The user-friendly web interface and CLI enable easy configuration and management, catering to network administrators' diverse levels of expertise.

Built with high-quality materials, Enterasys Networks devices are designed to withstand the rigors of a data center environment, ensuring longevity and reliable performance. The combination of these features makes the 4H4284-49, 4H4202-72, 4H4282-49, 4H4283-49, and 4H4203-72 models excellent choices for organizations looking to enhance their networking capabilities and ensure a secure, efficient communication network that can grow with their needs. Overall, Enterasys Networks continues to set benchmarks in networking technology, making significant strides in improving connectivity and performance for enterprises worldwide.