Dialogic DISI16-EW, DISI32-EW Telephony Connection Options, After Installing the Board

Page 2

not support this feature. Power Budgeting jumper P4 is designed to ensure proper configuration of the product.

The DISI board must be installed in a slot that can be allocated 25W.

If Power Budgeting is not implemented by a vendor's system, the DISI board must be plugged into a x4 or higher slot with the P4 jumper in position 1-2 (power budgeting ignored). This is allowed per PCI Express Card Electromechanical Specification Revision 1.0a or higher because a x4 or greater slot must be able to support a minimum of 25W.

If Power Budgeting is implemented by a vendor's system, the DISI board can be plugged into a x1 slot but the P4 jumper must be in position pins 2-3 (power budgeting adhered to).

WARNING! Installing the DISI board in a x1 slot with the P4 jumper in position 1-2 will void the warranty of the DISI board.

If the DISI will be connected to other telephony boards via a CT Bus cable, you should install the boards to minimize unused connectors on the CT Bus cable (in addition to ensuring that the power requirements are met):

Install boards in adjacent slots whenever possible.

If the DISI board will be connected to one or more PCI boards, use the PCI Express slot(s) closest to the PCI slots.

5. Installing the Board

WARNING! Unplug the equipment before performing the procedures described here. Failure to disconnect the power before you open the chassis can result in personal injury. Ensure that the system is disconnected from its power source and from all telecommunications links, networks, or modem lines whenever the chassis cover is removed. Do not operate the system with the cover removed.

CAUTION: To avoid possible damage to the board, remove power from the computer before beginning installation. Observe proper anti-static precautions at all times while handling and installing the board.

To install the DISI board, perform the following steps:

1.Turn off all power to the system and disconnect the system’s power cords.

2.Remove the computer’s cover.

3.Choose an empty PCI Express expansion slot and remove the slot’s retaining screw and access cover plate.

4.Insert the board’s edge connector into the bus slot, and apply firm pressure to the top edge of the board until the board is fully seated in the edge connector.

5.Reinstall the retaining screw.

6.Repeat steps 1 through 5 for any additional boards you are installing.

7.Connect the telephony boards together with a CT Bus cable of the appropriate size (not included). If possible, use a cable assembly that matches the number of boards in your system. If the cable has more than one unused connector, install the cable so that all the unused connectors are at one end of the cable.

8.Replace the computer’s cover.

9.Reconnect the computer’s power cord.

Audio Cable and Ferrite Clamp

A ferrite clamp is required on the audio cable to reduce RFI emissions from the PCB audio jack and to comply with the EN55022 Class B radio frequency interference limits. Follow these instructions to properly install the ferrite clamp:

1.Loop the cable once around the ferrite clamp, keeping cable snug and as close as possible to the plug to be installed into audio jack on the PCB.

2.Snap the ferrite clamp closed onto the cable.

3.Insert the plug into the audio jack.

Connect to Power Supply

The DISI board must be connected to an external power supply. The power module is the MSISCGBLPWRMOD MSI Global Power Module Assembly. One power module is required per DISI baseboard.

The external power module generates -24 volts to power the station interface loop and -70 volts for ringing. The power module connects to a pre-wired power cable attached to the DISI board.

6. Telephony Connection Options

The station ports on the DISI board are accessed using a telephony connection box such as the breakout box provided with the DISIBOBKIT breakout box and cable kit. Alternatively, the CBLTAC0X32 Telco Adapter Cable can be used for installations with a wall-mounted distribution frame and split 50 pair telephone punch down blocks, or with a standard rack-mount breakout solution (RJ121X to RJ11). Follow the instructions for the two possible connection scenarios:

Connect Board Using DISIBOBKIT Breakout Box and Cable Kit

The breakout box can be mounted using screws or double-sided tape. Follow one of the two sets below to connect the breakout box to the board.

Mounting Breakout Box Using Screws

Mounting Breakout Box Using Double-Sided Tape

Connect Board Using CBLTAC0X32 Telco Adapter Cable

The CBLTAC0X32 Telco Adapter Cable converts the 68-pin connector on the DISI board into two standard RJ21X Amphenol* connectors. Each RJ21X connector carries up to 16 stations, depending on the DISI analog station port density (16, 24, 32).

The CBLTAC0X32 is approximately 12 inches in length. Standard 25 pair Amphenol* cables should be used to extend the reach.

7. Pinouts for the Breakout Connector

Note: On the DISI24 (24-port board), only tip and ring pins 1-24 are active. On the DISI16 (16-port board), only tip and ring pins 1-16 are active.

Breakout Connector Pin Designations

Pin

Signal

Pin

Signal

 

 

 

 

 

 

1

RING2

35

TIP2

 

 

 

 

 

 

2

RING1

36

TIP1

 

 

 

 

 

 

3

RING4

37

TIP4

 

 

 

 

 

 

4

RING3

38

TIP3

 

 

 

 

 

 

5

RING6

39

TIP6

 

 

 

 

 

 

6

RING5

40

TIP5

 

 

 

 

 

 

7

RING8

41

TIP8

 

 

 

 

 

 

8

RING7

42

TIP7

 

 

 

 

 

 

9

RING18

43

TIP18

 

 

 

 

 

 

10

RING20

44

TIP20

 

 

 

 

 

 

11

RING19

45

TIP19

 

 

 

 

 

 

12

RING17

46

TIP17

 

 

 

 

 

 

13

RING21

47

TIP21

 

 

 

 

 

 

14

RING22

48

TIP22

 

 

 

 

 

 

15

RING23

49

TIP23

 

 

 

 

 

 

16

RING24

50

TIP24

 

 

 

 

 

 

17

NOT USED

51

NOT USED

 

 

 

 

 

 

18

NOT USED

52

NOT USED

 

 

 

 

 

 

19

RING26

53

TIP26

 

 

 

 

 

 

20

RING25

54

TIP25

 

 

 

 

 

 

21

RING28

55

TIP28

 

 

 

 

 

 

22

RING27

56

TIP27

 

 

 

 

 

 

23

RING30

57

TIP30

 

 

 

 

 

 

24

RING29

58

TIP29

 

 

 

 

 

 

25

RING32

59

TIP32

 

 

 

 

 

 

26

RING31

60

TIP31

 

 

 

 

 

 

27

RING14

61

TIP14

 

 

 

 

 

 

28

RING13

62

TIP13

 

 

 

 

 

 

29

RING16

63

TIP16

 

 

 

 

 

002-

30

RING15

64

TIP15

 

 

 

 

 

 

31

RING10

65

TIP10

2536

 

 

 

 

32

RING9

66

TIP9

 

 

 

 

05-

33

RING12

67

TIP12

 

 

 

 

ID:Doc.

34

RING11

68

TIP11

 

 

 

 

 

 

8. After Installing the Board

The DISI requires the use of a System Software version that specifically supports it. Required Dialogic System Software: System Release 6.0 PCI for Windows Service Update 137 or higher; System Release 6.1 for Linux Service Update 241 or higher.

If this is the first Dialogic telecom board installed in your system, you will need to install an appropriate System Software version and configure the software for the specific board(s) you are using. Refer to the installation and configuration documentation that accompanies the release for instructions.

If you are installing the DISI in a system that already has System Software installed, you should verify that the installed software version supports the board. If not, you will need to obtain and install a Service Update that does support the DISI before configuring the system for the newly installed board(s).

Please refer to the Release Update document for up- to-date information about support for PCI Express boards and any known issues relating to their use.

9. Removing the Board

Removal of the DISI board is essentially the reverse of the installation procedure:

1.Observe anti-static precautions.

2.Disconnect the telephony cables.

3.Remove the computer’s power cord.

4.Remove the computer’s cover.

5.Disconnect the CT Bus cable (if applicable).

6.Remove and set aside the board’s retaining screw.

7.Remove the board and place it static-protective packaging.

10.Contacting Technical Support

Dialogic provides technical support for its products through a network of value added distributors who are trained to answer technical questions on installing and configuring Dialogic products. If you are unsure how to contact your support channel, please call Dialogic in the United States at 973-967-6600 (9am - 5pm EST) and we will assist in obtaining the appropriate support channel. Outside the United States please refer to http://www.dialogic.com/ support/contact to obtain local contact information.

Dialogic also provides direct support via Dialogic® Pro™ Services agreements. For more details of direct support from Dialogic please refer to http:// www.dialogic.com/support/DialogicPro.

11.Returning a Product

To return a board for warranty repair or any other returns, please refer to the following: http://www.dialogic.com/support/hwfaults

Dialogic® is a registered trademark of Dialogic Corporation. Dialogic's trademarks may be used publicly only with permission from Dialogic. Such permission may only be granted by Dialogic’s legal department. The names of actual companies and products mentioned herein are the trademarks of their respective owners.

Image 2
Contents Before You Begin Configuring the BoardProduct Description Choosing a SlotAfter Installing the Board Installing the BoardPinouts for the Breakout Connector Telephony Connection Options