Eaton Electrical 9825 manual Best total reliability, Unmatched power performance and efficiency

Page 1

Powerware® 9395

Powerware® 9395-825 - Available Fall 2008

Uninterruptible Power System (UPS)

Uninterruptible Power System (UPS)

Product Focus

225 to 825 KVA

225 - 550 kVA

 

 

 

Benefits

The Powerware 9395 UPS is designed to meet the current and future power protection requirements of data centers, manufacturing operations, medical facilities and other large- system applications.

Best total reliability

Delivers the highest reliability and availability for large, mission-critical systems by inte- grating the capabilities of a redundant multi-module UPS (including the System Bypass Module) into a single, pre-wired unit

Unmatched power performance and efficiency

Provides unmatched power performance for efficiency, input current harmonic distortion (THD), and power factor

Scalable, redundant architecture meets current and future load requirements

Grows with changing power requirements using scalable architecture that allows you to add another 275 kVA module on-site later for capacity or redundancy

Integrates into total PowerChain Management solution from Eaton

Integrates seamlessly with Power Xpert® Architecture to enable you to monitor and manage the UPS as well as the entire power system, including all upstream and down- stream switchgear

Incorporating over 40 years of technology leadership in the design of mission-critical power systems, the Powerware 9395 is an innovative, state-of-the- art UPS designed to provide reliable power to your most critical loads. With its capability to be configured as a redundant system, the Powerware 9395 is ideal for applications such as large data centers, medical facilities, or any load that must operate 24x7x365 without interruption.

Taking large system mission– critical reliability to the next step

The Powerware 9395 combines the reliability and redundancy of a multi-module UPS into an integrated, pre-wired solution. The Powerware 9395 features N+1 redundancy, which allows one 275 kVA module to automatically carry the load in the event the other module is out of service. Up to three 275 kVA modules can be used in an integrated solution to match the capacity, reliability and redundancy needs of your application.

Advanced design delivers unequaled power performance

The innovative design of the Powerware 9395 delivers the industry’s best performance combination of efficiency, input current distortion and power factor. The Powerware 9395 operates at an industry–leading 95 percent efficiency, reducing utility costs and extending battery runtimes. Higher system efficiency produces cooler operating conditions, which reduces facility air conditioning cost, extends the life of UPS components, and increases overall reliability, availability,

and performance. A new input circuit design keeps input current THD low and input power factor near unity without compromising overall efficiency. As a result, the Powerware

9395 allows maximum transfer of power between power source and protected load and is exceptionally compatible with multiple power sources, especially auxiliary generators. On the output side, the ultra high speed switching Pulse Width Modulation (PWM) inverter enables the Powerware 9395 to provide its full rated power capability to the load whether the load power factor is 0.9 lagging, unity, or 0.9 leading.

For additional information, please call 1-800-392-3299 or email info@naat.com www.naat.com

Image 1
Contents Best total reliability Unmatched power performance and efficiencyService design maximizes uptime Uninterruptible Power System UPSAdvanced software allows you to see the entire picture Service and support enhance performanceInput Characteristics UPS Rating 0.9 power factorBattery Serviceability