Product Selection — Accessories

Table 3. Accessories — R, W-Frames

Description

 

Catalogue

 

 

Number

 

 

 

 

 

 

Toggle Cover Plates

For use with C362TR30MD & 40MD

CRP3

 

For use with C362TW60MD & 80MD

CWP3

 

 

 

Auxiliary Contacts

1NO for R-Frame (30 & 40 Amps)

CRAC3

Kit (Holder and

1NO for W-Frame (60 & 80 Amps)

CWAC3

Contact)

 

 

 

 

 

Auxiliary Contacts

1NO - for R, W-Frame

CRAB

(Additional Contacts)

1NC - for R, W-Frame

CRAA

 

 

 

Extension Support

 

C362SS1

 

 

Replacement Brass Collar R and W-Frames

CRC

 

 

Door Mounting Kit R and W-Frames

CTRFC

Rotary Switches

 

 

 

 

 

The mechanism is reversed on these contacts.

Table 4. Accessories — C, S, V, F-Frames

Description

 

Catalogue

 

 

 

Number

 

 

 

 

 

 

 

 

Auxiliary Contact

C-Frame (for 5-8)

CUCU

Holders

V-Frame (for 1-8)

CUVU

 

 

S-Frame (for 1-4)

CUSU

Auxiliary Contacts

1 NO, Type U aux. contact for

CUSAA

 

 

C, V, S Frames

CUSAB

 

 

1 NC, Type U aux. contact for

 

 

C, V, S Frames

 

 

 

 

 

 

 

1 NO/NC, Type S aux. contact, for

CUVAC 0

 

 

30A-400A V-Frames

CUVAD 0

 

 

2 NO/NC, Type S aux. contact, for

 

 

30A-400A V-Frames

 

 

 

 

 

 

 

1 NO/NC, Type ST aux. contact for

CUVXC 0

 

 

Fusible, 30A-400A V-Frame w/Test

CUVXD 0

 

 

2 NO/NC, Type ST aux. contact for

 

 

Fusible, 30A-400A V-Frame w/Test

 

 

 

 

 

 

 

1 NO/NC, Type MS aux. contact, for

CUFAC

 

 

Fusible 600A & 800A F-Frame

CUFAD

 

 

2 NO/NC, Type MS aux. contact, for

 

 

Fusible 600A & 800A F-Frame

 

Load-Side

3-Pole, V-Frame (200A)

CUV200T

Terminal Shrouds for

 

 

3-Pole, for Non-Fusible

CUS600T

Non-Fusible

S-Frame (400 - 600A)

 

V- and S-Frames

 

 

 

3-Pole, for Non-Fusible

CUS1200T

 

 

 

 

S-Frame (800 - 1200A)

 

 

 

 

 

Load-Side

3-Pole, for Fusible V-Frame (100A)

CUV100T

Terminal Shrouds for

3-Pole, V-Frame (200A)

CUV200T

Fusible V- and

3-Pole, for Fusible V-Frame (400A)

CUV400T

F-Frames

3-Pole, for Fusible F-Frame

CUF800T

 

 

(600 & 800A)

 

 

 

 

 

Shorting Links

V-Frame (60A)

CUV60SL

for 3 Poles

V-Frame (100A)

CUV100SL

Fusible, V- and

 

 

V-Frame (200A)

CUV200SL

F-Frames

V-Frame (400A)

CUV400SL

 

 

 

 

F-Frame (600 & 800A)

CUF800SL

 

 

 

 

Terminal Lugs

1 Wire/lug, Wire Size #12-2/0, for

CUV100LN

for Non-Fusible and

Fusible V-Frame (100A)

CUV200LN

Fusible V-, S- and

1 Wire/lug, Wire Size #6-3/0, for

F-Frames, for line or

V-Frame (200A)

CUS600LN

load side

2 Wires/lug, Wire Size #2-600,MCM

 

 

for V, S- & F-Frames (400 & 600A)

 

 

 

3 Wires/lug, Wire Size #2-600, MCM

CUS1000LN

 

 

for S-& F-Frames (800-1000A)

CUS1200LN

 

 

2 Wires/lug, Wire Size# 2-600, MCM

 

 

S-Frame (1200A)

 

 

 

 

 

C-Frames (standard product) hold 1-4 Auxiliary Contacts without additional holder.

Line-side terminal shrouds provided as standard on all ratings. Load-side terminal shrouds standard on non-fused C and V-Frames up through 100A.

Line-side terminal shrouds provided as standard on all ratings. Load-side terminal shrouds standard on fusible switches up through 60A.

Kit of 3.

Terminal lugs provided as standard on Non-Fusible up through 100A and Fusible up through 60A.

Kit of 3.

Kit of 6.

Aux contacts are “Early Break/Late Make.”

0Side mounted aux contact do not have “Early Break” - they open and close at the same time as the switch.

For more information visit us at: www.eatonelectrical.ca

Image 8
Contents Disconnect Switches Product Guide Disconnect Switches ContentsStandards and Certifications Options and AccessoriesProduct Description Rotary Disconnect Switches Product Description PadlockingDoor Interlock in on Position DefeaterProduct Selection Switches Catalogue Ordering InformationProduct Selection Handles and Shafts Handles and ShaftsCPBR5 CPYR5CPBW6 CPYW6Rotary Disconnect Switches Fusible/Non-Fusible Accessories Product Selection AccessoriesAccessories R, W-Frames Accessories C, S, V, F-FramesDimensions, Weights and Ratings Technical Data and SpecificationsDimensions in Inches mm Frame Ampere RatingRotary Disconnect Switches Non-fused DescriptionNon-Fusible V-Frames Dimensions in Inches mm Rotary Disconnect Switches Fusible Fusible V-Frames Dimensions in Inches mmDimensions in Inches mm Non-Fusible S-Frames Dimensions in Inches mm Fusible F-Frames Dimensions in Inches mm Frame Handle Type Selector Pistol Rotary Disconnect SwitchesHandles Dimensions in Inches mm CSA Technical Characteristics Description Frame Catalogue NumberTechnical Characteristics Motor Power kWRating Ampere 100 200 400 600/630 ➀ 800 1000 1250 ConnectionRotary Disconnect Switches Enclosed Switches Rotary Disconnect Switches Enclosed SwitchesEnclosed Rotary Additional Auxiliary ContactsRotary Disconnect Switches Enclosed Switches Variable Depth CDR303CDR306UD CDR380UD CDR3030UW CDR3040UW Type 4X Stainless Enclosure CDR3080UW CDR3060UW Mounting Holes December312 8 MM DIA Electrical Interlocks Handle Only1NO-1NC 2NO-2NCLine Lug Data Disconnect Switch TypeDisconnect Switch Size Wire Size Fixed Depth Flange to Panel Approximate DimensionsFrame Size Dimensions in Inches Accessories Type C361 Nema Safety Door HardwareType C361 Nema Safety Door Hardware Product SelectionChannel Support Kit Rod not supplied in Kit Mounting Dimension Requirements Technical Data and Specifications Product DescriptionCircuit Breaker Operating Mechanisms 150 C371FE1December December December