Before You Begin

Before you can install the Ulinx Extender, you need to prepare your site.

1.Determine where the host computer is to be located and set up the computer.

2.Determine where you want to locate the USB device(s).

3.Decide whether the power adapter is to be connected to the Local Unit or the Remote Unit (see the discussion of power handling on page 4).

4.If you are using surface cabling, ensure you have enough Category 5 UTP cabling to connect the two locations.

OR

If you are using premise cabling, ensure Category 5 UTP cabling is installed between the two locations, with Category 5 information outlets located near both the computer and the USB device.

Installing the Local Unit

1.Place the Local Unit near the host computer.

2.If the power adapter is to be located with the Local Unit:

a)Plug the power adapter into a suitable AC outlet.

b)Connect the power adapter to the Local Unit.

3.Plug the Type B connector on the USB cable (included) into the Host port on the Local Unit.

4.Plug the Type A connector on the USB cable into the USB port on the computer.

Installing the Remote Unit

1.Place the Remote Unit near the USB device(s).

2.If the power adapter is to be located with the Remote Unit:

a)Plug the power adapter into a suitable AC outlet.

b)Connect the power adapter to the Remote Unit.

Manual Documentation Number: UEC100M/4-2305

5

Connecting the Local Unit to the Remote Unit

NOTE:To ensure proper operation, we recommend that only Category 5 or better, Unshielded Twisted Pair (UTP) cabling be used to connect the Local Unit to the Remote Unit. The UTP cabling must have a straight-through conductor configuration with no crossovers, and must be terminated with 8-conductor RJ45 connectors at both ends.

With Surface Cabling

1.Plug one end of the Category 5 UTP cabling (not included) into the Link port on the Local Unit.

2.Plug the other end of the Category 5 UTP cabling into the Link port on the Remote Unit.

With Premise Cabling

1.Plug one end of a Category 5 patch cord (not included) into the Link port on the Local Unit.

2.Plug the other end of the patch cord into the Category 5 information outlet near the host computer.

3.Plug one end of the second Category 5 patch cord (not included) into the Link port on the Remote Unit.

4.Plug the other end of the second patch cord into the Category 5 information outlet near the USB device.

NOTE: The maximum length of the Category 5 UTP cable, including patch cords, must not exceed 100 meters.

Checking the Installation

1.Check that the Power LEDs on the Local Unit and Remote Unit are both on.

2.Check that the Link LEDs on the Local Unit and Remote Unit are both on.

3.Check that the Host LED on the Local Unit is on.

4.On the host PC, open the Device Manager applet. Expand the entry for Universal Serial Bus controllers by clicking the + sign. If the Ulinx Extender has been installed correctly you should find it listed as a Generic USB Hub.

6

Manual Documentation Number: UEC100M/4-2305

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104www.bb-elec.comB&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445www.bb-europe.com

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104www.bb-elec.comB&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445www.bb-europe.com

Image 6
Contents USB Extender FCC Radio Frequency Interference Statement Warning Table of Contents Ulinx Extender Product Contents IntroductionAbout the Ulinx Extender USB Cables Power HandlingRemote Unit Network CablingConnecting the Local Unit to the Remote Unit Installing the Local UnitInstalling the Remote Unit Checking the InstallationConnecting a USB Device TroubleshootingDisconnect and then reconnect the power Specifications Contacting Technical Support

Ulinx Extender, UEC100M/4 specifications

B&B Electronics has long been recognized for its commitment to providing innovative communication solutions, and the UEC100M/4 Ulinx Extender is a prime example of this dedication. This powerful device is designed to extend the reach of serial devices over Ethernet, making it an essential tool for various industrial and commercial applications.

One of the standout features of the UEC100M/4 is its ability to support multiple serial connections concurrently. Specifically, it allows for the connection of up to four serial devices over a single Ethernet connection. This multi-port capability is particularly advantageous in environments where numerous devices need to be managed efficiently, reducing the complexity of wiring and ensuring seamless communication.

The Ulinx technology incorporated in the UEC100M/4 promotes compatibility with a wide range of serial communication protocols, including RS-232, RS-422, and RS-485. This versatility means that users can easily integrate the extender with existing equipment without the need for extensive modifications or upgrades. Additionally, its robust design ensures reliable operation even in challenging industrial environments.

Another critical aspect of the UEC100M/4 is its impressive distance coverage. The device can extend serial communication over distances of up to 1.5 miles (or 2.4 kilometers) using conventional Ethernet cabling. This capability allows for flexible network configurations and the ability to connect devices that are situated far apart, making it ideal for large facilities.

The UEC100M/4 also incorporates advanced technologies such as error detection and correction mechanisms, ensuring that data integrity is maintained during transmission. This feature is essential for applications requiring high reliability, such as manufacturing and process control systems.

User-friendliness is a priority with the UEC100M/4. The device features an intuitive web interface, allowing users to set up and monitor connections easily. Additionally, it supports various networking protocols, including TCP/IP, UDP, and Telnet, providing flexibility in integrating with different systems.

In summary, the B&B Electronics UEC100M/4 Ulinx Extender is a highly effective solution for extending serial connections over Ethernet, with features such as multi-port connectivity, support for various serial protocols, long-distance communication, and an easy-to-use interface. Its combination of reliability and versatility makes it an ideal choice for a wide range of applications in today's demanding industrial landscape.