B&B Electronics 3PXCC1A Communication Jumper Settings, RS-232 Mode, RS-422 Mode, RS-485 Mode

Page 20

Chapter 5: Communication Jumper Settings

This chapter will cover all of the jumper settings to set your B&B Serial Card for the proper communications that you desire.

CAUTION: Electrostatic Sensitive Device.

Use ESD precautions for safe handling.

RS-232 Mode

To configure a port for RS-232 mode, 5 jumpers must be checked. The following settings will configure Port 1 as RS-232.

1.JP1A - must be set in the "232" (left) position.

2.JP1F - all four jumpers must be set in the "232" (left) position.

Jumpers JP1B - JP1E have no meaning in RS-232 mode and may be in either position. Figure 2 shows the jumper configuration to set both ports for RS-232 mode.

Figure 2. RS-232 Mode Jumper Settings

Documentation No.3PXCC1x-2x-3903

35

RS-422 Mode

To configure a port for RS-422 mode, 7 jumpers must be checked. The following settings configure Port 1 as RS-422.

1.JP1A, JP1B, JP1C - must be set in the "422" (right) position.

2.JP1F - all four jumpers must be in the "422" (right) position.

Figure 3 shows the jumper configuration to set both ports for RS-422 mode.

Figure 3. RS-422 Mode Jumper Settings

Note that the EIA RS-422 Specification labels data lines with an "A" and "B" designator. Some RS-422 equipment uses a "+" and "-" designator. In almost all cases, the "A" line is the equivalent of the "-" line and the "B" line is the equivalent of the "+" line. More information on RS-422 communications can be found in B&B Electronics’ free RS-422/RS-485 Application Note.

RS-485 Mode

To configure a port for RS-485 mode, 9 jumpers must be checked. The following settings configure Port 1 as RS-485.

1.JP1A - must be set in the "422" (right) position.

2.JP1B, JP1C - must be set in the "485" (left) position.

3.JP1D, JP1E - set to match software and installation requirements.

4.JP1F - all four jumpers must be in the "422" (right) position.

36

Documentation No.3PXCC1x-2x-3903

B&B Electronics Mfg Co – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104

B&B Electronics Mfg Co – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104

B&B Electronics Ltd – Westlink Comm. Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445

B&B Electronics Ltd – Westlink Comm. Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445

Image 20
Contents RS-232/422/485 Serial Cards CE Table of Contents Introduction and General Information FeaturesSpecifications Quick Installation Guide Use ESD precautions for safe handlingDocumentation No.3PXCC1x-2x-3903 Adding Serial Ports in Windows 95/98 Click Next Changing COM Port Resources in Windows 95/98 Select Basic Configuration 0007 or last one Documentation No.3PXCC1x-2x-3903 Checking Windows 2000 for Available Address/IRQ’s Adding Serial Ports in Windows NTClick on View top of screen. Click on Resources by type Adding Serial Ports in Windows Documentation No.3PXCC1x-2x-3903 Documentation No.3PXCC1x-2x-3903 Documentation No.3PXCC1x-2x-3903 Address and IRQ Setting Address Switch Setup Silk Screen Plot of 3PXCC PCBInterrupt Jumper Setup Standard IRQ Settings COM1 IRQ4 COM2 IRQ3 COM3 COM4Communication Jumper Settings RS-232 ModeRS-422 Mode RS-485 ModeRS-485 Operation High Speed ModeRS-422 and RS-485 Termination Physical Hook-up and Troubleshooting PinoutsTroubleshooting Communication Cable DataInternational/USA Office European OfficeMap of AT Class Machines Appendix a Hardware I/O MapMap of XT Class Machines Appendix B Declaration of Conformity Statement Declaration of Conformity