4.Mounting the Remote Access Module 4

1.Hold the IND-RAM4 unit against the wall in its intended position. Using the mounting brackets as a template, mark the position of the fixing hole on each side. These are approximately 145mm apart horizontally.

2.Drill and insert two wall plugs and then mount the IND-RAM4 unit on the wall.

3.Connect the serial cable (CAB-RAM) from the units SERIAL INTERFACE (DTE) socket (25-pin D-type) to one of the INDeX cabinet's serial ports (9-pin D-types).

To use the modem link for remote database up and downloads, you must connect the serial cable to the first INDeX serial port.

4.Connect the line lead from the unit's LINE socket to the direct exchange line master socket.

A dedicated direct exchange line must be used to allow the unit to operate independent of the INDeX system.

5.Plug the output lead of the Plug Top 9V Power Supply into the female socket and then connect the plug top into a suitable mains power outlet. When power is applied, press the Power Switch on the front of the unit and the MR light on the unit will illuminate.

Page 8

User's Guide

Remote Access Module 4

38DHB0002UKDS – Issue 2 (09/01/2002)

Image 8
Contents Remote Access Module Contents Previous Remote Access Module Kits OverviewSecurity You mustLocation Requirements Rack SystemsRemote Access Module 4 Kit Equipment Supplied & RequiredTools & part Required OptionalAttaching the Mounting Brackets Mounting the Remote Access Module Installing for Use With INDeX IVM/CCM IVM Server Cassette InstallationIVM/CCM Client Installation Using IND-RAM4 with IVM and CCMRestoring INDeX Remote Access Module Defaults To locally restore the Remote Access Module settingsRemote Access Module 38DHB0002UKDS Issue 2 09/01/2002