Table 1. RS-422/485 Port

 

Terminal

 

RS-422/485

 

Block

 

Signal

 

Signal

Description

Direction of

 

 

 

Port

 

FR GND

Frame Ground

<------>

 

TD(A)(-)

Transmit Data (A)(-)

Output

 

TD(B)(+)

Transmit Data (B)(+)

Output

 

RD(A)(-)

Receive Data (A)(-)

Input

 

RD(B)(+)

Receive Data (B)(+)

Input

 

GND

Signal Ground

<------>

 

+12VDC

Power Supply

Input

RS-232 Port

 

 

The RS-232 DTE port is an asynchronous port that supports TD and RD signals. In order to make the proper connections to the RS- 232 port. It is necessary to have a basic understanding of the terms DCE and DTE. The original design for connecting RS-232 devices together uses DB25 connectors, and connects a DTE (Data Terminal Equipment) device to a DCE (Data Communication Equipment) device. Each device will have inputs on pins that correspond to outputs on the same pins of the other device. For example, a DTE device transmits data out on pin 2 and a DCE device receives data in on pin 2. IBM PC's are DTE devices and modems are DCE devices. Only TD and RD of the RS-232 port pass through to the RS-485 port when the 485DSS is ON. The 485DSS raises and lowers the RTS output signal on the RS-232 port to reflect the connect state of the port. This signal can notify the RS-232 device to start communicating to the Host or it can be an alarm output. The Host can monitor the CTS input line to determine if the RS-232 device is requesting access to the network. This input line could also be an alarm input. NOTE: If using RTS or CTS lines as alarms the user may have to design additional circuitry to properly interface to the alarm circuits. Refer to cable charts in Appendix C for making your own cables.

485DSS-0308 Manual

3

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91 792444 – Fax +353 91 792445

Image 7
Contents 485DSS-0308 Manual Cover Electronics Mfg. Co. IncDesigned and Manufactured Ottawa, Illinois InternetPage Table of Contents IiTable of Contents 485DSS-0308 Manual Hardware Introduction ChecklistPort Configuration SpecificationsRS-485/422 Port Signal Ground +12VDC Power Supply Input RS-422/485 Port Terminal Block Signal Description DirectionRS-232 Port Frame Ground Transmit Data Output Receive Data Input Clear to Send Input Signal GroundRS-422/485 Wiring Wire ModeComponent Values For Send Data Timing RS-485 Wiring Diagram Wire Mode RS-422 Wiring Diagram RS-485 and RS-422 Termination Power SupplyOperation Distributed Smart Switch Commands Communication ConfigurationHex Command StringOn Command DecimalStatus Request Command OFF CommandPage ACK Address Switch Setting the 485DSS AddressDIP Switch Binary File Transfer Software Description 485DSS-0308 Manual Appendix a Appendix a Ascii Character CodesPage 485DSS-0308 Manual Appendix B SymbolAppendix B Decimal/Hexadecimal/Conversions Dec/Hex Conversions Decimal HexadecimalDecimal to Hexadecimal Conversion Hexadecimal to Decimal ConversionRS-232 DTE Port Appendix C Cable ChartsChart 1. IBM PC DB25 Connector to 485DSS RS-232 DTE Port RS-232 DTE Port DB25 Connector DirectionRS-485/422 Chart 6. RS-485 2-Wire Device to 485DSS RS-485/422 PortDevice Direction Terminal Blocks
Related manuals
Manual 26 pages 24.25 Kb