B&B Electronics manual Setting the 485DSS Address, Address Switch, DIP Switch

Page 18

Unit 17 decimal (11 hex) waited 360 milliseconds and then sent a reply indicating no connection of the RS-232 port to the network and the CTS handshake line is in the high state.

If you were writing a program in BASIC to request status from address 5 decimal, you might form a string like this:

DSS05RS$ = CHR$(19) + "0" + "5" + CHR$(6)

You could then send DSS05RS$ to request status from 485DSS address 5. Use similar strings for requesting status from other individual 485DSS's.

If you were writing a program in BASIC to request status from all the 485DSS's on the network, you might form a string like this:

DSSALLRS$ = CHR$(19) + CHR$(18) + CHR$(18) + CHR$(6)

You could then send DSSALLRS$ to request status from all the 485DSS's on the network.

Setting the 485DSS Address

Assign each 485DSS on the RS-485 network its own unique address. To set the address use the eight position DIP switch on the 485DSS labeled “SW1”. Refer to Figure 2 for the location of the switch. To access this switch, you will need to remove the top cover of the 485DSS. Insert a small screwdriver in the slot in the side of the cover and twist to remove it. Each switch position is equal to a specific weight value. Set the 485DSS to any decimal address from 0 to 255. To assign the new address to the 485DSS, cycle the power on the unit.

Table 4. Address Switch

 

DECIMAL

HEX

DIP Switch 1

WEIGHT

WEIGHT

1

1

1

2

2

2

3

4

4

4

8

8

5

16

10

6

32

20

7

64

40

8

128

80

OFF = Weight False

ON = Weight True

Factory Default Address = 0

 

 

14

485DSS-0308 Manual

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91 792444 – Fax +353 91 792445

Image 18
Contents Internet Electronics Mfg. Co. IncDesigned and Manufactured Ottawa, Illinois 485DSS-0308 Manual CoverPage Table of Contents IiTable of Contents 485DSS-0308 Manual Checklist Hardware IntroductionSpecifications Port ConfigurationRS-485/422 Port RS-422/485 Port Terminal Block Signal Description Direction Signal Ground +12VDC Power Supply InputRS-232 Port Wire Mode Clear to Send Input Signal GroundRS-422/485 Wiring Frame Ground Transmit Data Output Receive Data InputComponent Values For Send Data Timing RS-485 Wiring Diagram Wire Mode Power Supply RS-422 Wiring Diagram RS-485 and RS-422 TerminationOperation Communication Configuration Distributed Smart Switch CommandsDecimal Command StringOn Command Hex OFF Command Status Request CommandPage ACK Setting the 485DSS Address Address SwitchDIP Switch Binary File Transfer Software Description Appendix a Ascii Character Codes 485DSS-0308 Manual Appendix aPage Dec/Hex Conversions Decimal Hexadecimal SymbolAppendix B Decimal/Hexadecimal/Conversions 485DSS-0308 Manual Appendix BHexadecimal to Decimal Conversion Decimal to Hexadecimal ConversionRS-232 DTE Port DB25 Connector Direction Appendix C Cable ChartsChart 1. IBM PC DB25 Connector to 485DSS RS-232 DTE Port RS-232 DTE PortChart 6. RS-485 2-Wire Device to 485DSS RS-485/422 Port RS-485/422Device Direction Terminal Blocks