Avocent DSR1021 manual To connect a Dsriq module to a server

Page 21

Chapter 2: Installation

9

 

 

2.Plug the VGA monitor and PS/2 keyboard and mouse cables into the corresponding DSR1021/1022 switch ports. You must install both a keyboard and mouse on the local port, or the keyboard will not initialize properly.

3.Choose an available numbered port on the back panel of the DSR1021/1022 switch. Plug one end of a CAT 5 patch cable (4-pair, up to 10 meters) into the selected port and plug the other end into the RJ-45 connector of a DSRIQ module.

4.Plug the DSRIQ module into the corresponding ports on the back panel of the target server. Repeat this procedure for all servers that are to be connected to the DSR1021/1022 switch. See the To connect a DSRIQ module to a server procedure on page 9 and the To connect a DSRIQ module to a serial device procedure on page 10 for more information.

5.Plug a CAT 5 patch cable from your Ethernet network into the LAN port on the back of the DSR1021/1022 switch. Network users will access the DSR1021/1022 switch through this port.

6.(Optional) The DSR1021/1022 switch can also be accessed using a ITU V.92, V.90 or V.34- compatible modem. Plug the 9-pin serial cable into the MODEM port on the back of the DSR1021/1022 switch. Plug the other end into the connector on the modem.

NOTE: Using a modem connection instead of a LAN connection will limit the performance capability of your DSR1021/1022 switch.

7.(Optional) Plug one end of the cable supplied with the SPC power control device into the SPC port on the DSR1021/1022 switch and plug the other end into an SPC device. Plug the power cords from the target servers into the SPC device power outlets. Plug the SPC device into an appropriate AC wall outlet.

8.If you are configuring the DSR1021/1022 switch using the console menu interface, use the supplied null modem cable to connect a terminal or PC running terminal emulation software (such as HyperTerminal®) to the SETUP port on the back panel of the DSR1021/1022 switch. Set the terminal to 9600 bits per second (bps), 8 bits, 1 stop bit, no parity and no flow control.

9.Power up each target device and then power up the DSR1021/1022 switch. After approximately one minute, the switch completes initialization and displays the OSCAR® graphical user interface Free tag on the local port monitor.

10.If you did not use the console menu interface to configure the DSR1021/1022 switch, use the DSView 3 software to configure the switch. See the DSView Installer/User Guide or the DSView 3 Online Help for detailed instructions.

To connect a DSRIQ module to a server:

1.Attach the color-coded connectors of a DSRIQ module to the corresponding keyboard, monitor and mouse ports on the server you will be connecting to the DSR1021/1022 switch.

Image 21
Contents DSR Switch Power on DSR1021/1022 Switch USA Notification Japanese Approvals Safety and EMC Standards Table of Contents Local Port Operation Terminal Operations Index List of Figures Viii DSR1021/1022 Switch Installer/User Guide List of Tables DSR1021/1022 Switch Installer/User Guide Reduce cable bulk Features and BenefitsAccess the DSR1021/1022 switch via network connection Two modes of access to the DSR1021/1022 switchSimple access to any target device DSR1021/1022 switch Ethernet DSView Modem Rack Mount Safety Considerations Safety PrecautionsDSR 1021/1022 Switch Connectivity InstallationInstallation Overview Setting up your networkInstalling the DSR1021/1022 switch Digital User Ethernet CordConnections Items supplied with the DSR1021/1022 switch Connecting the DSR1021/1022 Switch HardwareTo connect and power on your DSR1021/1022 switch Getting StartedTo connect a Dsriq module to a server DSR1021/1022 switch Verifying the ConnectionsTo connect a Dsriq module to a serial device Adjusting Mouse Settings on Target Devices Configuring the Web Server and DSView 3 SoftwareSetting up the built-in web server Setting Up the DSView SoftwareMicrosoft Windows Click the Pointer Options tab Linux Installation 16 DSR1021/1022 Switch Installer/User Guide Unix 18 DSR1021/1022 Switch Installer/User Guide Novell NetWare Apple Mac OS To access the Oscar interface Main dialog box Controlling Your System at the Local PortViewing and Selecting Ports and Servers Viewing the status of your DSR1021/1022 switching system Selecting target devicesTo select target devices To configure the Oscar interface screen delay Soft switchingTo soft switch to a target device To select the previous target deviceEscape Navigating the Oscar InterfaceLocal Port Operation Configuring Oscar Interface MenusTo access the Oscar interface Setup dialog box To access the Oscar interface Names dialog boxAssigning target device names Names Dialog Box To assign names to target devicesTo access the Oscar interface Devices dialog box Assigning device typesTo list target devices alphabetically by name To assign a device type Changing the display behaviorTo choose the display order of target devices To access the Oscar interface Menu dialog boxTo set a Screen Delay Time for the Oscar interface To access the Oscar interface Flag dialog boxControlling the status flag Flag Dialog Box To determine how the status flag is displayedBroadcasting to target devices To access the Oscar interface Broadcast dialog boxUsing Scan mode To broadcast to selected target devicesTo turn off Broadcasting 11 Scan Dialog Box To add target devices to the Scan listTo remove a target device from the Scan list To start the Scan modeSetting local port Screen Saver options To cancel Scan modeTo access the Oscar interface Screen Saver dialog box To set the Screen Saver options To exit Screen Saver mode and log in to the local portSetting the keyboard country code To immediately turn on the screen saverTo set the keyboard country code for Sun servers 40 DSR1021/1022 Switch Installer/User Guide To access the Oscar interface Commands dialog box Managing Server Tasks Using the Oscar InterfaceViewing and disconnecting user connections To view current user connectionsTo disconnect a user To reset the PS/2 mouse and keyboard values Resetting your PS/2 keyboard and mouseTo display version information Displaying version informationClick X to close the Dsriq Version dialog box 46 DSR1021/1022 Switch Installer/User Guide To log in to the DSR web server Overview of the DSR1021/1022 Web ServerDescribes some of the DSR Explorer window areas About the DSR Explorer WindowUsing the side navigation bar Using the top option barBookmarking a window Internet Explorer only Launching a KVM session Logging OutRebooting the appliance To disconnect an active KVM session Administrator onlyTo reboot the DSR1021/1022 switch remotely Managing a DSR web server deviceManaging Local Accounts Managing Device Properties Viewing and changing appliance configuration informationPower Controlling Target Devices Video Viewer minimum requirements About the Video Viewer WindowTo enable, disable or configure the session time-out Launching a KVM SessionSession time-out Video Viewer Window Normal Window Mode Video Viewer Window Features58 DSR1021/1022 Switch Installer/User Guide To change the Video Viewer window resolution Setting the Window SizeChanging the toolbar To specify a toolbar hide timeAdjusting the View To align the mouse cursorsTo refresh the screen Adjusting color depth To enable or disable full screen modeTo enable automatic, full or manual scaling To manually adjust the video quality of the window Additional Video AdjustmentDetection thresholds Contrast and brightnessAutomatic video adjustment Adjusting Mouse OptionsBlock noise threshold and pixel noise threshold Refresh imageCursor Type To enter single cursor modeTo exit single cursor mode To select a key for exiting single cursor modeTo change the mouse cursor setting Mouse ScalingUsing Keyboard Pass-through Mouse Alignment and SynchronizationTo realign the mouse Saving the View Using MacrosTo close a Video Viewer window session Closing a Video Viewer Window Session70 DSR1021/1022 Switch Installer/User Guide Network Configuration To configure network settings using the Console menuConsole Menu 72 DSR1021/1022 Switch Installer/User Guide Terminal Operations To add a user to the DSR1021/1022 switch database Security ConfigurationOther Console Main Menu Options Local User AccountsReset Certificates Console PasswordTo rename a user in the DSR1021/1022 switch database To remove a user from the DSR1021/1022 switch databaseEnable Debug Messages Secure ModeRestore Factory Defaults Reset ApplianceAppendices Appendix a Flash Upgrades78 DSR1021/1022 Switch Installer/User Guide Before you begin Appendix B Using DSView Software Over a Modem ConnectionDSRIQ-SRL module modes Appendix C Using DSRIQ-SRL ModulesCtrl-F8 To configure a DSRIQ-SRL module Creating a DSRIQ-SRL module macroTo create a macro DSRIQ-SRL module pinouts To use History modeUTP copper cabling Appendix D UTP CablingCabling installation, maintenance and safety tips Table E.1 DSR1021/1022 Switch Product Specifications Appendix E Technical SpecificationsType Serial RS-232 Connectors DB9 Male Appendix F Sun Advanced Key Emulation Appendices Appendix G Technical Support Numerics IndexModule 7, 8, 9, 10, 11, 51, 77, 80 Mode 81, 82 PPP Status LED 96 DSR1021/1022 Switch Installer/User Guide Page 590-427-501B
Related manuals
Manual 110 pages 43.71 Kb