Operating Manual -
Other Features
Front Panel Lock-Out
When unintended or unauthorized control changes need to be prevented, a keyed switch or contact closure can be connected to the lockout connector. When the two lockout pins are uncon- nected, the front panel operates normally. When the lockout pins are connected closed, physical changes on the front panel are locked out and ignored by software. Note: Before unlocking the front panel, it is suggested that all faders first be placed fully down or at
Factory Reset
To restore the unit to it’s default settings and erase all stored parameters, follow these steps:
1)Remove power from the
2)Press and hold down buttons 1, 2, 3, 4 on the
3)Apply power, holding the buttons down for a count of four as indicated by the lighting of four red LEDs. To cancel the reset, release all buttons before the count to four is complete.
4)A successful reset is indicated when all LEDs glow amber, then the buttons can be released.
Security
In addition to the hardware lockout, there are multiple user/ multiple levels of
Firmware Update (Flash
Reprogram)
To view the current FR firmware revision, click on
the control surface Network Properties tab and look under Hardware Configuration. If a newer firmware update is available on the Ashly website, download it and run the Flash Reprogram pro- cedure found in the FR Device Options menu. If the control surface is somehow unable to com- municate with the FR device due to a corrupt internal program, run flash reprogram from the main Proteane window under Flash Programmer/Launch Flash Reprogram. This requires the FR device MAC address, found on the FR back panel (see procedure in the troubleshooting section). When the FR device is put into flash reprogram mode, the highest channel LED turns green and the Master LED turns amber. All control function is suspended until